115 research outputs found

    Performances of 4H-SiC Schottky diodes as neutron detectors

    Get PDF
    Abstract Large area 4H-SiC Schottky diodes equipped with a 6LiF converter were tested as neutron detectors in the epithermal column realized for Boron Neutron Capture Therapy (BNCT) applications at the fast reactor TAPIRO (ENEA Casaccia Roma). The neutron spectra were assessed using the Monte Carlo code MCNP-4C. The performances of SiC detectors were evaluated with neutron fluences in the range of 109–1013 cm−2 which is typical for BNCT. Spectra of alpha and tritium particles generated by 6Li(n,α)3H reaction were collected at various neutron fluences and spectra obtained by interposing polyethylene moderators of different thickness. Only weak damaging effects primarily due to the alpha particles were observed; at neutron fluence of 1013 cm−2 the count rate decreased b

    Off–label long acting injectable antipsychotics in real–world clinical practice: a cross-sectional analysis of prescriptive patterns from the STAR Network DEPOT study

    Get PDF
    Introduction: Information on the off–label use of Long–Acting Injectable (LAI) antipsychotics in the real world is lacking. In this study, we aimed to identify the sociodemographic and clinical features of patients treated with on– vs off–label LAIs and predictors of off–label First– or Second–Generation Antipsychotic (FGA vs. SGA) LAI choice in everyday clinical practice. Method: In a naturalistic national cohort of 449 patients who initiated LAI treatment in the STAR Network Depot Study, two groups were identified based on off– or on–label prescriptions. A multivariate logistic regression analysis was used to test several clinically relevant variables and identify those associated with the choice of FGA vs SGA prescription in the off–label group. Results: SGA LAIs were more commonly prescribed in everyday practice, without significant differences in their on– and off–label use. Approximately 1 in 4 patients received an off–label prescription. In the off–label group, the most frequent diagnoses were bipolar disorder (67.5%) or any personality disorder (23.7%). FGA vs SGA LAI choice was significantly associated with BPRS thought disorder (OR = 1.22, CI95% 1.04 to 1.43, p = 0.015) and hostility/suspiciousness (OR = 0.83, CI95% 0.71 to 0.97, p = 0.017) dimensions. The likelihood of receiving an SGA LAI grew steadily with the increase of the BPRS thought disturbance score. Conversely, a preference towards prescribing an FGA was observed with higher scores at the BPRS hostility/suspiciousness subscale. Conclusion: Our study is the first to identify predictors of FGA vs SGA choice in patients treated with off–label LAI antipsychotics. Demographic characteristics, i.e. age, sex, and substance/alcohol use co–morbidities did not appear to influence the choice towards FGAs or SGAs. Despite a lack of evidence, clinicians tend to favour FGA over SGA LAIs in bipolar or personality disorder patients with relevant hostility. Further research is needed to evaluate treatment adherence and clinical effectiveness of these prescriptive patterns

    Comparing Long-Acting Antipsychotic Discontinuation Rates Under Ordinary Clinical Circumstances: A Survival Analysis from an Observational, Pragmatic Study

    Get PDF
    Background: Recent guidelines suggested a wider use of long-acting injectable antipsychotics (LAI) than previously, but naturalistic data on the consequences of LAI use in terms of discontinuation rates and associated factors are still sparse, making it hard for clinicians to be informed on plausible treatment courses. Objective: Our objective was to assess, under real-world clinical circumstances, LAI discontinuation rates over a period of 12 months after a first prescription, reasons for discontinuation, and associated factors. Methods: The STAR Network ‘Depot Study’ was a naturalistic, multicentre, observational prospective study that enrolled subjects initiating a LAI without restrictions on diagnosis, clinical severity or setting. Participants from 32 Italian centres were assessed at baseline and at 6 and 12 months of follow-up. Psychopathology, drug attitude and treatment adherence were measured using the Brief Psychiatric Rating Scale, the Drug Attitude Inventory and the Kemp scale, respectively. Results: The study followed 394 participants for 12 months. The overall discontinuation rate at 12 months was 39.3% (95% confidence interval [CI] 34.4–44.3), with paliperidone LAI being the least discontinued LAI (33.9%; 95% CI 25.3–43.5) and olanzapine LAI the most discontinued (62.5%; 95% CI 35.4–84.8). The most frequent reason for discontinuation was onset of adverse events (32.9%; 95% CI 25.6–40.9) followed by participant refusal of the medication (20.6%; 95% CI 14.6–27.9). Medication adherence at baseline was negatively associated with discontinuation risk (hazard ratio [HR] 0.853; 95% CI 0.742–0.981; p = 0.026), whereas being prescribed olanzapine LAI was associated with increased discontinuation risk compared with being prescribed paliperidone LAI (HR 2.156; 95% CI 1.003–4.634; p = 0.049). Conclusions: Clinicians should be aware that LAI discontinuation is a frequent occurrence. LAI choice should be carefully discussed with the patient, taking into account individual characteristics and possible obstacles related to the practicalities of each formulation

    Performance of irradiated CVD diamond micro-strip sensors

    Get PDF
    CVD diamond detectors are of interest for charged particle detection and tracking due to their high radiation tolerance. In this article we present, for the first time, beam test results from recently manufactured CVD diamond strip detectors and their behavior under low doses of electrons from a ÎČ\beta-source and the performance before and after intense (>1015/cm2>10^{15}/{\rm cm^2}) proton- and pion-irradiations. We find that low dose irradiations increase the signal-to-noise ratio (pumping of the signal) and slightly deteriorate the spatial resolution. Intense irradiations with protons (2.2×1015 p/cm22.2\times 10^{15}~p/{\rm cm^2}) lowers the signal-to-noise ratio slightly. Intense irradiation with pions (2.9×1015 π/cm22.9\times 10^{15}~\pi/{\rm cm^2}) lowers the signal-to-noise ratio more. The spatial resolution of the diamond sensors improves after irradiations

    Development of Diamond Tracking Detectors for High Luminosity Experiments at LHC

    Get PDF
    During 2006 detectors based on new polycrystalline CVD (pCVD) material were produced as candidates for use in LHC experiments. The first full size diamond pixel module with ATLAS specifications using a 2×62 \times 6 cm2^2 pCVD sample was characterized in the 2006 CERN test beam. Radiation damage studies performed outside of CERN corroborate the radiation hardness of this material. Radiation hardness studies at CERN using the highest quality diamond were deferred until 2007 due to the PS magnet problem. ATLAS, CMS, ALICE and LHCb are planning to use diamond for their beam conditions monitoring systems. Construction of the BCM system for ATLAS was completed in 2006 and the BCM modules were characterized in 2006 CERN test beams. Similar devices are under construction for the CMS, ALICE and LHCb experiments. Single-crystal CVD (scCVD) samples were produced and made available to RD42 institutes. The first scCVD diamond pixel device was constructed and tested in the 2006 CERN test beams. In this report we present the progress and work done by the RD42 collaboration on the development of CVD diamond material for radiation detectors
    • 

    corecore