270 research outputs found

    Total knee arthroplasty in valgus knee

    Get PDF
    SummaryTotal knee arthroplasty (TKA) in valgus knee has the reputation of being more difficult than in well aligned or varus knee, and there is no management consensus. Results on a continuous series of 100 TKAs on valgus knee were compared to the literature data, to define surgical strategy adapted to the various types of valgus knee

    Total shoulder arthroplasty – Arthroplasty for glenohumeral arthropathies: Results and complications after a minimum follow-up of 8years according to the type of arthroplasty and etiology

    Get PDF
    SummaryIntroductionArthroplasty for glenohumeral arthropathies have specific complications and the final results are sometimes more dependent upon the type of shoulder arthroplasty than the initial etiology. The aim of our study was to evaluate the rate of complications and the functional improvement with different types of shoulder arthroplasties after a minimum follow-up of 8years.Materials and methodsThis was a multicenter retrospective study of 198 shoulders including 85 primary osteoarthritis of the shoulder, 76 cuff tear arthropathies, 19 avascular necrosis and 18 rheumatoid arthritis. Arthroplasties included 104 anatomic total shoulder arthroplasties (TSA), 77 reverse arthroplasties and 17 hemiarthroplasties. Ten patients had their arthroplasty revised, and 134 patients with TSA were able to be present at the final follow-up or provide information on their case. Function was evaluated by the Constant-Murley score and loosening by standard radiographs.ResultsIn the group with primary osteoarthritis of the shoulder, there were eight complications (11%) including six (8.3%) requiring implant revision. In the group of rotator cuff arthropathies, there were nine (14.7%) complications including four (6.5%) requiring implant revision. In the group with rheumatoid arthritis, there was one complication, and no surgical revision was necessary. There were no complications in the group with avascular necrosis. Glenoid migration occurred in 28.5% of anatomic TSA, and 3.4% of reverse arthroplasties. This difference was significant (P<0.001). The Constant-Murley score was significantly improved in all etiologies.ConclusionsGlenohumeral arthropathies can be successfully treated by arthroplasty. Anatomic TSA was shown to be associated with a high risk of glenoid loosening at radiographic follow-up, which makes us hesitate to use the cemented polyethylene implant, especially in young patients.Level of evidenceIV – Retrospective study

    The Level-0 Muon Trigger for the LHCb Experiment

    Get PDF
    A very compact architecture has been developed for the first level Muon Trigger of the LHCb experiment that processes 40 millions of proton-proton collisions per second. For each collision, it receives 3.2 kBytes of data and it finds straight tracks within a 1.2 microseconds latency. The trigger implementation is massively parallel, pipelined and fully synchronous with the LHC clock. It relies on 248 high density Field Programable Gate arrays and on the massive use of multigigabit serial link transceivers embedded inside FPGAs.Comment: 33 pages, 16 figures, submitted to NIM

    Adiabatic passage and ensemble control of quantum systems

    Full text link
    This paper considers population transfer between eigenstates of a finite quantum ladder controlled by a classical electric field. Using an appropriate change of variables, we show that this setting can be set in the framework of adiabatic passage, which is known to facilitate ensemble control of quantum systems. Building on this insight, we present a mathematical proof of robustness for a control protocol -- chirped pulse -- practiced by experimentalists to drive an ensemble of quantum systems from the ground state to the most excited state. We then propose new adiabatic control protocols using a single chirped and amplitude shaped pulse, to robustly perform any permutation of eigenstate populations, on an ensemble of systems with badly known coupling strengths. Such adiabatic control protocols are illustrated by simulations achieving all 24 permutations for a 4-level ladder

    The impact of Stieltjes' work on continued fractions and orthogonal polynomials

    Full text link
    Stieltjes' work on continued fractions and the orthogonal polynomials related to continued fraction expansions is summarized and an attempt is made to describe the influence of Stieltjes' ideas and work in research done after his death, with an emphasis on the theory of orthogonal polynomials

    The ANTARES Optical Beacon System

    Get PDF
    ANTARES is a neutrino telescope being deployed in the Mediterranean Sea. It consists of a three dimensional array of photomultiplier tubes that can detect the Cherenkov light induced by charged particles produced in the interactions of neutrinos with the surrounding medium. High angular resolution can be achieved, in particular when a muon is produced, provided that the Cherenkov photons are detected with sufficient timing precision. Considerations of the intrinsic time uncertainties stemming from the transit time spread in the photomultiplier tubes and the mechanism of transmission of light in sea water lead to the conclusion that a relative time accuracy of the order of 0.5 ns is desirable. Accordingly, different time calibration systems have been developed for the ANTARES telescope. In this article, a system based on Optical Beacons, a set of external and well-controlled pulsed light sources located throughout the detector, is described. This calibration system takes into account the optical properties of sea water, which is used as the detection volume of the ANTARES telescope. The design, tests, construction and first results of the two types of beacons, LED and laser-based, are presented.Comment: 21 pages, 18 figures, submitted to Nucl. Instr. and Meth. Phys. Res.

    Cadaveric and three-dimensional computed tomography study of the morphology of the scapula with reference to reversed shoulder prosthesis

    Get PDF
    <p>Abstract</p> <p>Purpose</p> <p>The purpose of this study is to analyze the morphology of the scapula with reference to the glenoid component implantation in reversed shoulder prosthesis, in order to improve primary fixation of the component.</p> <p>Methods</p> <p>Seventy-three 3-dimensional computed tomography of the scapula and 108 scapular dry specimens were analyzed to determine the anterior and posterior length of the glenoid neck, the angle between the glenoid surface and the upper posterior column of the scapula and the angle between the major craneo-caudal glenoid axis and the base of the coracoid process and the upper posterior column.</p> <p>Results</p> <p>The anterior and posterior length of glenoid neck was classified into two groups named "short-neck" and "long-neck" with significant differences between them. The angle between the glenoid surface and the upper posterior column of the scapula was also classified into two different types: type I (mean 50°–52°) and type II (mean 62,50°–64°), with significant differences between them (p < 0,001). The angle between the major craneo-caudal glenoid axis and the base of the coracoid process averaged 18,25° while the angle with the upper posterior column of the scapula averaged 8°.</p> <p>Conclusion</p> <p>Scapular morphological variability advices for individual adjustments of glenoid component implantation in reversed total shoulder prosthesis. Three-dimensional computed tomography of the scapula constitutes an important tool when planning reversed prostheses implantation.</p

    Visualization of plasmid delivery to keratinocytes in mouse and human epidermis

    Get PDF
    The accessibility of skin makes it an ideal target organ for nucleic acid-based therapeutics; however, effective patient-friendly delivery remains a major obstacle to clinical utility. A variety of limited and inefficient methods of delivering nucleic acids to keratinocytes have been demonstrated; further advances will require well-characterized reagents, rapid noninvasive assays of delivery, and well-developed skin model systems. Using intravital fluorescence and bioluminescence imaging and a standard set of reporter plasmids we demonstrate transfection of cells in mouse and human xenograft skin using intradermal injection and two microneedle array delivery systems. Reporter gene expression could be detected in individual keratinocytes, in real-time, in both mouse skin as well as human skin xenografts. These studies revealed that non-invasive intravital imaging can be used as a guide for developing gene delivery tools, establishing a benchmark for comparative testing of nucleic acid skin delivery technologies
    • …
    corecore