2,010 research outputs found

    Correlations in Hot Asymmetric Nuclear Matter

    Get PDF
    The single-particle spectral functions in asymmetric nuclear matter are computed using the ladder approximation within the theory of finite temperature Green's functions. The internal energy and the momentum distributions of protons and neutrons are studied as a function of the density and the asymmetry of the system. The proton states are more strongly depleted when the asymmetry increases while the occupation of the neutron states is enhanced as compared to the symmetric case. The self-consistent Green's function approach leads to slightly smaller energies as compared to the Brueckner Hartree Fock approach. This effect increases with density and thereby modifies the saturation density and leads to smaller symmetry energies.Comment: 7 pages, 7 figure

    Path Integral Variational Methods for Strongly Correlated Systems

    Get PDF
    We introduce a new approach to highly correlated systems which generalizes the Fermi Hypernetted Chain and Correlated Basis Function techniques. While the latter approaches can only be applied to systems for which a nonrelativistic wave function can be defined, the new approach is based on the variation of a trial hamiltonian within a path integral framework and thus can also be applied to relativistic and field theoretical problems. We derive a diagrammatic scheme for the new approach and show how a particular choice of the trial hamiltonian corresponds exactly to the use of a Jastrow correlated ansatz for the wave function in the Fermi Hypernetted Chain approach. We show how our new approach can be used to find upper bounds to ground state energies in systems which the FHNC cannot handle, including those described by an energy-dependent effective hamiltonian. We demonstrate our approach by applying it to a quantum field theoretical system of interacting pions and nucleons.Comment: 35 RevTeX pages, 7 separated ps figures available on reques

    DEMUX devices based on a-SiC:H

    Get PDF
    In this paper we present results about the functioning of a multilayered a-SiC:H heterostructure as a device for wavelength-division demultiplexing of optical signals. The device is composed of two stacked p-i-n photodiodes, both optimized for the selective collection of photogenerated carriers. Band gap engineering was used to adjust the photogeneration and recombination rates profiles of the intrinsic absorber regions of each photodiode to short and long wavelength absorption and carrier collection in the visible spectrum. The photocurrent signal using different input optical channels was analyzed at reverse and forward bias and under steady state illumination. This photocurrent is used as an input for a demux algorithm based on the voltage controlled sensitivity of the device. The device functioning is explained with results obtained by numerical simulation of the device, which permit an insight to the internal electric configuration of the double heterojunction.These results address the explanation of the device functioning in the frequency domain to a wavelength tunable photocapacitance due to the accumulation of space charge localized at the internal junction. The existence of a direct relation between the experimentally observed capacitive effects of the double diode and the quality of the semiconductor materials used to form the internal junction is highlighted

    Number--conserving model for boson pairing

    Full text link
    An independent pair ansatz is developed for the many body wavefunction of dilute Bose systems. The pair correlation is optimized by minimizing the expectation value of the full hamiltonian (rather than the truncated Bogoliubov one) providing a rigorous energy upper bound. In contrast with the Jastrow model, hypernetted chain theory provides closed-form exactly solvable equations for the optimized pair correlation. The model involves both condensate and coherent pairing with number conservation and kinetic energy sum rules satisfied exactly and the compressibility sum rule obeyed at low density. We compute, for bulk boson matter at a given density and zero temperature, (i) the two--body distribution function, (ii) the energy per particle, (iii) the sound velocity, (iv) the chemical potential, (v) the momentum distribution and its condensate fraction and (vi) the pairing function, which quantifies the ODLRO resulting from the structural properties of the two--particle density matrix. The connections with the low--density expansion and Bogoliubov theory are analyzed at different density values, including the density and scattering length regime of interest of trapped-atoms Bose--Einstein condensates. Comparison with the available Diffusion Monte Carlo results is also made.Comment: 21 pages, 12 figure

    Minimum alveolar concentrations and hemodynamic effects of two different preparations of sevoflurane in pigs

    Get PDF
    BACKGROUND: Original sevoflurane (Sevo A) is made with water, while a generic sevoflurane (Sevocris) is produced with propylene glycol as a stabilizing additive. We investigated whether the original and generic sevoflurane preparations differed in terms of their minimum alveolar concentration (MAC) values and hemodynamic effects. METHODS: Sixteen pigs weighing 31.6±1.8 kg were randomly assigned to the Sevo A or Sevocris groups. After anesthesia induction via mask with the appropriate sevoflurane preparation (6% in 100% oxygen), the MAC was determined for each animal. Hemodynamic and oxygenation parameters were measured at 0.5 MAC, 1 MAC and 1.5 MAC. Histopathological analyses of lung parenchyma were performed. RESULTS: The MAC in the Sevo A group was 4.4±0.5%, and the MAC in the Sevocris group was 4.1±0.7%. Hemodynamic and metabolic parameters presented significant differences in a dose-dependent pattern as expected, but they did not differ between groups. Cardiac indices and arterial pressures decreased in both groups when the sevoflurane concentration increased from 0.5 to 1 and 1.5 MAC. The oxygen delivery index (DO2I) decreased significantly at 1.5 MAC. CONCLUSION: Propylene glycol as an additive for sevoflurane seems to be as safe as a water additive, at least in terms of hemodynamic and pulmonary effects

    Momentum distribution of liquid helium

    Full text link
    We have obtained the one--body density matrix and the momentum distribution n(p)n(p) of liquid 4^4He at T=3D0oT=3D0^oK from Diffusion Monte Carlo (DMC) simulations, using trial functions optimized via the Euler Monte Carlo (EMC) method. We find a condensate fraction smaller than in previous calculations. Though we do not explicitly include long--range correlations in our calculations, we get a momentum distribution at long wavelength which is compatible with the presence of long--range correlations in the exact wave function. We have also studied 3^3He, using fixed--node DMC, with nodes and trial functions provided by the EMC. In particular, we analyze the momentum distribution n(p)n(p) with respect to the discontinuity ZZ as well as the singular behavior, at the Fermi surface. We also show that an approximate factorization of the one-body density matrix ρ(r)ρ0(r)ρB(r)\rho(r)\simeq \rho_0(r)\rho_B(r) holds, with ρ0(r)\rho_0(r) and ρB(r)\rho_B(r) respectively the density matrix of the ideal Fermi gas and the density matrix of a Bose 3^3He.Comment: 10 pages, REVTeX, 12 figure

    A Systematic Review and Aggregated Analysis on the Impact of Amyloid PET Brain Imaging on the Diagnosis, Diagnostic Confidence, and Management of Patients being Evaluated for Alzheimer's Disease.

    Get PDF
    BACKGROUND: Amyloid PET (aPET) imaging could improve patient outcomes in clinical practice, but the extent of impact needs quantification. OBJECTIVE: To provide an aggregated quantitative analysis of the value added by aPET in cognitively impaired subjects. METHODS: Systematic literature searches were performed in Embase and Medline until January 2017. 1,531 cases over 12 studies were included (1,142 cases over seven studies in the primary analysis where aPET was the key biomarker; the remaining cases included as defined groups in the secondary analysis). Data was abstracted by consensus among two observers and assessed for bias. Clinical utility was measured by diagnostic change, diagnostic confidence, and patient management before and after aPET. Three groups were further analyzed: control patients for whom feedback of aPET scan results was delayed; aPET Appropriate Use Criteria (AUC+) cases; and patients undergoing additional FDG/CSF testing. RESULTS: For 1,142 cases with only aPET, 31.3% of diagnoses were revised, whereas 3.2% of diagnoses changed in the delayed aPET control group (p < 0.0001). Increased diagnostic confidence following aPET was found for 62.1% of 870 patients. Management changes with aPET were found in 72.2% of 740 cases and in 55.5% of 299 cases in the control group (p < 0.0001). The diagnostic value of aPET in AUC+ patients or when FDG/CSF were additionally available did not substantially differ from the value of aPET alone in the wider population. CONCLUSIONS: Amyloid PET contributed to diagnostic revision in almost a third of cases and demonstrated value in increasing diagnostic confidence and refining management plans

    "Outfow occlusion" para parada circulatória em cães

    Get PDF
    The purpose of this study was to evaluate the possibility of producing circulatory arrest by occlusion of the pulmonary trunk as an alternative to the venous inflow occlusion through the left hemithorax. Eight healthy mongrel dogs were divided in two groups. Group I underwent 4 minutes of outflow occlusion and Group II was submitted to 8 minutes of circulatory arrest. Outflow occlusion was performed through left thoracotomy and pericardiotomy by passing a Rumel tourniquet around the pulmonary trunk. Physical examination, electrocardiography, echocardiography, blood gas analyses, hemodynamic, and oxygen transport variables were obtained before and after the procedure. The dogs from Group I did not have any clinical, electrocardiographic, echocardiographic, or hemo-dynamic abnormalities after anesthetic recover. In the Group II, only one dog survived, which had no clinical, electrocardiographic, or echocardiographic abnormalities. In this last dog, just after releasing the occlusion, it was detected increases in the following parameters: heart rate (HR), systolic, diastolic and mean arterial blood pressure (SAP; DAP; MAP), pulmonary artery pressure (PAP), pulmonary wedge pressure (PWP), central venous pressure (CVP), cardiac output (CO), systolic index (SI), cardiac index (CI), left and right ventricular stroke work (LVSW; RVSW), oxygen delivery index (DO2), oxygen consumption index (VO2), and oxygen extraction (O2 ext). Moreover, the oxygen content of arterial and mixed venous blood (CaO2; CvO2), and the arterial and mixed venous partial pressure of oxygen (PaO2; PvO2) were decreased 5 minutes after circulatory arrest. Outflow occlusion is a feasible surgical procedure for period of 4 minutes of circulatory arrest.O objetivo deste estudo foi avaliar a possibilidade de se produzir uma parada circulatória pela oclusão do tronco pulmonar, como alternativa ao "inflow occlusion", pelo hemitórax esquerdo. Oito cães sem raça definida foram divididos em dois grupos. O Grupo I foi submetido a quatro minutos de parada circulatória e o Grupo II, a 8 minutos de parada. Realizou-se o "outflow occlusion" por meio de toracotomia intercostal esquerda e pericardiotomia, passando-se um torniquete de Rumel ao redor do tronco pulmonar. Foram realizados exame físico, eletrocardiografia, ecocardiografia, hemogasometria, avaliação hemodinâmica e cálculo de variáveis de transporte de oxigênio, antes e após o procedimento. Os cães do Grupo I não sofreram alterações clínicas, eletrocardiográficas, ecocardiográficas e hemodinâmicas após a recuperação anestésica. No Grupo II, apenas um animal sobreviveu, sem apresentar alterações clínicas, eletrocardiográficas e ecocardiográficas. Neste cão, após a liberação do torniquete, houve aumento nas seguintes variáveis: freqüência cardíaca, pressões arteriais sistólica, média e diastólica, pressão arterial pulmonar, pressão da artéria pulmonar ocluída, pressão venosa central, débito cardíaco, índice sistólico, índice cardíaco, trabalho ventricular esquerdo e direito, índice de transporte de oxigênio, índice de consumo de oxigênio e taxa de extração de oxigênio. O conteúdo de oxigênio arterial e venoso misto e a pressão parcial de oxigênio arterial e venosa mista diminuíram, cinco minutos após a parada circulatória. Concluiu-se que o "outflow occlusion" é um procedimento viável para a realização de parada circulatória por um período de quatro minutos.Fundação para o Amparo da Pesquisa no Estado de São Paulo (FAPESP

    Landau parameters of nuclear matter in the spin and spin-isospin channels

    Get PDF
    The equation of state of spin and isospin polarized nuclear matter is determined in the framework of the Brueckner theory including three-body forces. The Landau parameters in the spin and spin-isospin sectors are derived as a function of the baryonic density. The results are compared with the Gamow-Teller collective modes. The relevance of G0G_0 and G0G_0' for neutron stars is shortly discussed, including the magnetic susceptibility and the neutron star cooling.Comment: 2 pages, 2 figures, RevTex4 forma
    corecore