692 research outputs found

    Leptogenesis in SO(10) models with a left-right symmetric seesaw mechanism

    Full text link
    We study leptogenesis in supersymmetric SO(10) models with a left-right symmetric seesaw mechanism, including flavour effects and the contribution of the next-to-lightest right-handed neutrino. Assuming M_D = M_u and hierarchical light neutrino masses, we find that successful leptogenesis is possible for 4 out of the 8 right-handed neutrino mass spectra that are compatible with the observed neutrino data. An accurate description of charged fermion masses appears to be an important ingredient in the analysis.Comment: Submitted for the SUSY07 proceedings, 4 pages, 9 figure

    Regulatory T cells in melanoma revisited by a computational clustering of FOXP3+ T cell subpopulations

    Get PDF
    CD4+ T cells that express the transcription factor FOXP3 (FOXP3+ T cells) are commonly regarded as immunosuppressive regulatory T cells (Treg). FOXP3+ T cells are reported to be increased in tumour-bearing patients or animals, and considered to suppress anti-tumour immunity, but the evidence is often contradictory. In addition, accumulating evidence indicates that FOXP3 is induced by antigenic stimulation, and that some non-Treg FOXP3+ T cells, especially memory-phenotype FOXP3low cells, produce proinflammatory cytokines. Accordingly, the subclassification of FOXP3+ T cells is fundamental for revealing the significance of FOXP3+ T cells in tumour immunity, but the arbitrariness and complexity of manual gating have complicated the issue. Here we report a computational method to automatically identify and classify FOXP3+ T cells into subsets using clustering algorithms. By analysing flow cytometric data of melanoma patients, the proposed method showed that the FOXP3+ subpopulation that had relatively high FOXP3, CD45RO, and CD25 expressions was increased in melanoma patients, whereas manual gating did not produce significant results on the FOXP3+ subpopulations. Interestingly, the computationally-identified FOXP3+ subpopulation included not only classical FOXP3high Treg but also memory-phenotype FOXP3low cells by manual gating. Furthermore, the proposed method successfully analysed an independent dataset, showing that the same FOXP3+ subpopulation was increased in melanoma patients, validating the method. Collectively, the proposed method successfully captured an important feature of melanoma without relying on the existing criteria of FOXP3+ T cells, revealing a hidden association between the T cell profile and melanoma, and providing new insights into FOXP3+ T cells and Treg

    Theoretical mass sensitivity of Love wave and layer guided acoustic plate mode sensors

    Get PDF
    A model for the mass sensitivity of Love wave and layer guided shear horizontal acoustic plate mode (SH–APM) sensors is developed by considering the propagation of shear horizontally polarized acoustic waves in a three layer system. A dispersion equation is derived for this three layer system and this is shown to contain the dispersion equation for the two layer system of the substrate and the guiding layer plus a term involving the third layer, which is regarded as a perturbing mass layer. This equation is valid for an arbitrary thickness perturbing mass layer. The perturbation, Δν, of the wave speed for the two-layer system by a thin third layer of density, ρp and thickness Δh is shown to be equal to the mass per unit area multiplied by a function dependent only on the properties of the substrate and the guiding layer, and the operating frequency of the sensor. The independence of the function from the properties of the third layer means that the mass sensitivity of the bare, two-layer, sensor operated about any thickness of the guiding layer can be deduced from the slope of the numerically or experimentally determined dispersion curve. Formulas are also derived for a Love wave on an infinite thickness substrate describing the change in mass sensitivity due to a change in frequency. The consequences of the various formulas for mass sensing applications are illustrated using numerical calculations with parameters describing a (rigid) poly(methylmethacrylate) wave-guiding layer on a finite thickness quartz substrate. These calculations demonstrate that a layer-guided SH–APM can have a mass sensitivity comparable to, or higher, than that of Love waves propagating on the same substrate. The increase in mass sensitivity of the layer guided SH–APMs over previously studied SH–APM sensors is of significance, particularly for liquid sensing applications. The relevance of the dispersion curve to experiments using higher frequencies or frequency hopping and to experiments using thick guiding layers is discussed

    Unconventional Uses of Microcantilevers as Chemical Sensors in Gas and Liquid Media

    Get PDF
    The use of microcantilevers as (bio)chemical sensors usually involves the application of a chemically sensitive layer. The coated device operates either in a static bending regime or in a dynamic flexural mode. While some of these coated devices may be operated successfully in both the static and the dynamic modes, others may suffer from certain shortcomings depending on the type of coating, the medium of operation and the sensing application. Such shortcomings include lack of selectivity and reversibility of the sensitive coating and a reduced quality factor due to the surrounding medium. In particular, the performance of microcantilevers excited in their standard out-of-plane dynamic mode drastically decreases in viscous liquid media. Moreover, the responses of coated cantilevers operating in the static bending mode are often difficult to interpret. To resolve these performance issues, the following emerging unconventional uses of microcantilevers are reviewed in this paper: (1) dynamic-mode operation without using a sensitive coating, (2) the use of in-plane vibration modes (both flexural and longitudinal) in liquid media, and (3) incorporation of viscoelastic effects in the coatings in the static mode of operation. The advantages and drawbacks of these atypical uses of microcantilevers for chemical sensing in gas and liquid environments are discussed

    Unconventional Uses of Cantilevers for Chemical Sensing in Gas and Liquid Environments

    Get PDF
    Microcantilevers used as (bio)chemical sensors are usually coated with a chemically sensitive layer. The coated devices operate either in a static bending regime or in a dynamic flexural mode. While the coated devices operate generally well in both the static and dynamic mode, they do suffer from certain shortcomings depending on the medium of operation and the application, including lack of selectivity and of reversibility of the sensitive coating and a reduced quality factor due to the surrounding medium. In particular, the performance of microcantilevers excited in their standard out-of-plane dynamic mode drastically decreases in viscous liquid media. Moreover, the responses of coated cantilevers operating in the static bending mode are often difficult to interpret. To resolve those performance issues, unconventional uses of microcantilever are reviewed in this paper, which consist of the use of the dynamic mode without sensitive coating, the use of in-plane (flexural and longitudinal) vibration modes in liquid media, and fully accounting for the viscoelastic effects of the coatings in the static mode of operation. The advantages and drawbacks of these unconventional uses of microcantilevers for chemical sensing in gas and liquid environments are discussed

    Study of Viscoelastic Effect on the Frequency Shift of Microcantilever Chemical Sensors (proceedings)

    Get PDF
    Microcantilevers coated with a chemically sensitive layer are increasingly being used in chemical detection systems. The sensitive coating, often a polymer, absorbs specific molecules, which can be detected by monitoring the shift in the mechanical resonant frequency. Usually, the frequency shift resulting from molecular absorption is interpreted as a mass loading effect. However, mass loading is not the only effect that has an impact on the frequency shift; the viscoelastic properties of the sensitive coating are also affected by the sorption process. Sorption-induced modulus changes are typically difficult to characterize. However, it is known that the sorption of analyte molecules in a polymer coating results in the plasticization of the coating. In most cases, the polymer becomes more rubbery with increasing concentration of analyte molecules, i.e., the coating becomes softer with increasing loss modulus while the storage modulus decreases. Using a new analytical model developed for the resonant frequency expression of a hybrid microcantilever (elastic base and viscoelastic layer), the effects of the modification of the storage and loss moduli of the sensitive layer on the resonant frequency are examined. The main conclusion of this analytical study is that, even if the sensitive coating moduli are small compared to the base cantilever\u27s Young\u27s modulus, the effect of the change in the viscoelastic coating properties could contribute significantly to the overall frequency shift (8-23% in the simulations depending on the coating thickness, with even higher contributions for other sets of problem parameters)

    Effect of Viscoelasticity on Quality Factor of Microcantilever Chemical Sensors: Optimal Coating Thickness for Minimum Limit of Detection

    Get PDF
    Microcantilevers with polymer coatings hold great promise as resonant chemical sensors. It is known that the coated cantilever sensitivity increases with coating thickness; however, the drawback of increasing the coating thickness is the increase of the frequency noise and thus the deterioration of the sensor\u27s limit of detection. In this paper, an analytical expression for the viscoelastic losses in the coating, hence the quality factor is established and is used to explain the observed increase of the frequency noise with the polymer thickness. This result is then used to demonstrate that an optimum coating thickness exists that minimise the limit of detectio

    Coherent Backscattering of Ultracold Atoms

    Full text link
    We report on the direct observation of coherent backscattering (CBS) of ultracold atoms, in a quasi-two-dimensional configuration. Launching atoms with a well-defined momentum in a laser speckle disordered potential, we follow the progressive build up of the momentum scattering pattern, consisting of a ring associated with multiple elastic scattering, and the CBS peak in the backward direction. Monitoring the depletion of the initial momentum component and the formation of the angular ring profile allows us to determine microscopic transport quantities. The time resolved evolution of the CBS peak is studied and is found a fair agreement with predictions, at long times as well as at short times. The observation of CBS can be considered a direct signature of coherence in quantum transport of particles in disordered media. It is responsible for the so called weak localization phenomenon, which is the precursor of Anderson localization.Comment: 5 pages, 4 figure
    corecore