40 research outputs found

    Chronic wasting disease prions are not transmissible to transgenic mice overexpressing human prion protein

    Get PDF
    Chronic wasting disease (CWD) is a prion disease that affects free-ranging and captive cervids, including mule deer, white-tailed deer, Rocky Mountain elk and moose. CWD-infected cervids have been reported in 14 USA states, two Canadian provinces and in South Korea. The possibility of a zoonotic transmission of CWD prions via diet is of particular concern in North America where hunting of cervids is a popular sport. To investigate the potential public health risks posed by CWD prions, we have investigated whether intracerebral inoculation of brain and spinal cord from CWD-infected mule deer transmits prion infection to transgenic mice overexpressing human prion protein with methionine or valine at polymorphic residue 129. These transgenic mice have been utilized in extensive transmission studies of human and animal prion disease and are susceptible to BSE and vCJD prions, allowing comparison with CWD. Here, we show that these mice proved entirely resistant to infection with mule deer CWD prions arguing that the transmission barrier associated with this prion strain/host combination is greater than that observed with classical BSE prions. However, it is possible that CWD may be caused by multiple prion strains. Further studies will be required to evaluate the transmission properties of distinct cervid prion strains as they are characterized

    Prevention of surgical site infections in spine surgery: an international survey of clinical practices among expert spine surgeons

    Get PDF
    Study Design: Questionnaire-based survey.Objectives: Surgical site infection (SSI) is a common complication in spine surgery but universal guidelines for SSI prevention are lacking. The objectives of this study are to depict a global status quo on implemented prevention strategies in spine surgery, common themes of practice and determine key areas for future research.Methods: An 80-item survey was distributed among spine surgeons worldwide via email. The questionnaire was designed and approved by an International Consensus Group on spine SSI. Consensus was defined as more than 60% of participants agreeing to a specific prevention strategy.Results: Four hundred seventy-two surgeons participated in the survey. Screening for Staphylococcus aureus (SA) is not common, whereas preoperative decolonization is performed in almost half of all hospitals. Body mass index (BMI) was not important for surgery planning. In contrast, elevated HbAIc level and hypoalbuminemia were often considered as reasons to postpone surgery. Cefazoline is the common drug for antimicrobial prophylaxis. Alcohol-based chlorhexidine is mainly used for skin disinfection. Double-gloving, wound irrigation, and tissue-conserving surgical techniques are routine in the operating room (OR). Local antibiotic administration is not common. Wound closure techniques and postoperative wound dressing routines vary greatly between the participating institutions.Conclusions: With this study we provide an international overview on the heterogeneity of SSI prevention strategies in spine surgery. We demonstrated a large heterogeneity for pre-, peri- and postoperative measures to prevent SSI. Our data illustrated the need for developing universal guidelines and for testing areas of controversy in prospective clinical trails.Scientific Assessment and Innovation in Neurosurgical Treatment Strategie

    Regional and experiential differences in surgeon preference for the treatment of cervical facet injuries: a case study survey with the AO Spine Cervical Classification Validation Group

    Get PDF
    Purpose: The management of cervical facet dislocation injuries remains controversial. The main purpose of this investigation was to identify whether a surgeon’s geographic location or years in practice influences their preferred management of traumatic cervical facet dislocation injuries. Methods: A survey was sent to 272 AO Spine members across all geographic regions and with a variety of practice experience. The survey included clinical case scenarios of cervical facet dislocation injuries and asked responders to select preferences among various diagnostic and management options. Results: A total of 189 complete responses were received. Over 50% of responding surgeons in each region elected to initiate management of cervical facet dislocation injuries with an MRI, with 6 case exceptions. Overall, there was considerable agreement between American and European responders regarding management of these injuries, with only 3 cases exhibiting a significant difference. Additionally, results also exhibited considerable management agreement between those with ≤ 10 and > 10 years of practice experience, with only 2 case exceptions noted. Conclusion: More than half of responders, regardless of geographical location or practice experience, identified MRI as a screening imaging modality when managing cervical facet dislocation injuries, regardless of the status of the spinal cord and prior to any additional intervention. Additionally, a majority of surgeons would elect an anterior approach for the surgical management of these injuries. The study found overall agreement in management preferences of cervical facet dislocation injuries around the globe

    Transmission of Chronic Wasting Disease Identifies a Prion Strain Causing Cachexia and Heart Infection in Hamsters

    Get PDF
    Chronic wasting disease (CWD) is an emerging prion disease of free-ranging and captive cervids in North America. In this study we established a rodent model for CWD in Syrian golden hamsters that resemble key features of the disease in cervids including cachexia and infection of cardiac muscle. Following one to three serial passages of CWD from white-tailed deer into transgenic mice expressing the hamster prion protein gene, CWD was subsequently passaged into Syrian golden hamsters. In one passage line there were preclinical changes in locomotor activity and a loss of body mass prior to onset of subtle neurological symptoms around 340 days. The clinical symptoms included a prominent wasting disease, similar to cachexia, with a prolonged duration. Other features of CWD in hamsters that were similar to cervid CWD included the brain distribution of the disease-specific isoform of the prion protein, PrPSc, prion infection of the central and peripheral neuroendocrine system, and PrPSc deposition in cardiac muscle. There was also prominent PrPSc deposition in the nasal mucosa on the edge of the olfactory sensory epithelium with the lumen of the nasal airway that could have implications for CWD shedding into nasal secretions and disease transmission. Since the mechanism of wasting disease in prion diseases is unknown this hamster CWD model could provide a means to investigate the physiological basis of cachexia, which we propose is due to a prion-induced endocrinopathy. This prion disease phenotype has not been described in hamsters and we designate it as the ‘wasting’ or WST strain of hamster CWD

    Dual-Frequency Piezoelectric Transducers for Contrast Enhanced Ultrasound Imaging

    Get PDF
    For many years, ultrasound has provided clinicians with an affordable and effective imaging tool for applications ranging from cardiology to obstetrics. Development of microbubble contrast agents over the past several decades has enabled ultrasound to distinguish between blood flow and surrounding tissue. Current clinical practices using microbubble contrast agents rely heavily on user training to evaluate degree of localized perfusion. Advances in separating the signals produced from contrast agents versus surrounding tissue backscatter provide unique opportunities for specialized sensors designed to image microbubbles with higher signal to noise and resolution than previously possible. In this review article, we describe the background principles and recent developments of ultrasound transducer technology for receiving signals produced by contrast agents while rejecting signals arising from soft tissue. This approach relies on transmitting at a low-frequency and receiving microbubble harmonic signals at frequencies many times higher than the transmitted frequency. Design and fabrication of dual-frequency transducers and the extension of recent developments in transducer technology for dual-frequency harmonic imaging are discussed
    corecore