Impact of blood volume on the diffuse reflectance spectra of human skin measured in visible and NIR spectral ranges
We consider changes in the volume of blood and oxygen saturation caused by a pulse wave and their influence on the diffuse reflectance spectra in the visible/NIR spectral range. CUDA-based Monte-Carlo model was used for routine simulation of detector depth sensitivity (sampling volume) and skin spectra, and their variations associated with physiological changes in the human skin. The results presented in the form of animated graphs of sampling volume changes for scaling of the parameters of the main human skin layers related to the results of experimental measurements are of particular interest for pulse oximetry, photoplethysmography, Doppler flowmetry, reflectance spectroscopy
Spectral analysis of the blood flow in the foot microvascular bed during thermal testing in patients with diabetes mellitus
Timely diagnostics of microcirculatory system abnormalities, which are the most severe diabetic complications, is one of the major problems facing modern health care. Functional abnormalities manifest themselves earlier than the structural ones, and therefore their assessment is the issue of primary importance. In this study Laser Doppler flowmetry, a noninvasive technique for the cutaneous blood flow monitoring, was utilized together with local temperature tests and wavelet analysis. The study of the blood flow in the microvascular bed of toes was carried out in the control group of 40 healthy subjects and in two groups of 17 type 1 and 23 type 2 diabetic patients. The local temperature tests demonstrated that the diabetic patients have impaired vasodilation in response to local heating. The tendency for impaired low frequency pulsations of the blood flow associated with endothelial and neurogenic activities in both diabetes groups was observed. Local thermal tests induced variations in perfusion and its spectral characteristics, which were different in the groups under study. In our opinion, the obtained preliminary results can be a basis for further research and provide a deeper understanding of pathological processes that drive microvascular abnormalities caused by diabetes mellitus
Multimodal optical diagnostics of the microhaemodynamics in upper and lower limbs
The introduction of optical non-invasive diagnostic methods into clinical practice can substantially advance in the detection of early microcirculatory disorders in patients with different diseases. This paper is devoted to the development and application of the optical non-invasive diagnostic approach for the detection and evaluation of the severity of microcirculatory and metabolic disorders in rheumatic diseases and diabetes mellitus. The proposed methods include the joint use of laser Doppler flowmetry, absorption spectroscopy and fluorescence spectroscopy in combination with functional tests. This technique showed the high diagnostic importance for the detection of disturbances in peripheral microhaemodynamics. These methods have been successfully tested as additional diagnostic techniques in the field of rheumatology and endocrinology. The sensitivity and specificity of the proposed diagnostic procedures have been evaluated.<br/
Multimodal Optical Diagnostics of the Microhaemodynamics in Upper and Lower Limbs
The introduction of optical non-invasive diagnostic methods into clinical practice can substantially advance in the detection of early microcirculatory disorders in patients with different diseases. This paper is devoted to the development and application of the optical non-invasive diagnostic approach for the detection and evaluation of the severity of microcirculatory and metabolic disorders in rheumatic diseases and diabetes mellitus. The proposed methods include the joint use of laser Doppler flowmetry, absorption spectroscopy and fluorescence spectroscopy in combination with functional tests. This technique showed the high diagnostic importance for the detection of disturbances in peripheral microhaemodynamics. These methods have been successfully tested as additional diagnostic techniques in the field of rheumatology and endocrinology. The sensitivity and specificity of the proposed diagnostic procedures have been evaluated
Verification of NADH content measurements by portable optical diagnostic system in living brain tissue
The overall aim of this study was verification of the possibility to register the change of NADH fluorescence in live tissue by a portable diagnostical laser system with fibre optical probe output and excitation by compact semiconductor UV light source. The measurements were conducted in fresh brain tissue slices of Wistar rat pups. The fluorescence measurements were conducted simultaneously at intervals of 5 s by the microscopic system with excitation at 360 nm and registering of the emitted fluorescence light at 455 nm and by the tested diagnostical system equipped with the fibre optical probe with excitation at 365 nm and registration of the fluorescence spectrum by the inbuilt spectroscopic subsystem. To modulate the mitochondrial function in the living cells, in the chamber sequentially were added 1 μM FCCP and 1 mM NaCN. The comparisons between the curves registered by the methods allowed us to find well agreement between the microscopic measurements and measurements by the fibre optical probe. The obtained results prove that the tested diagnostic system is capable of sensing the changes in brain metabolic activity associated with the NADH content alterations within the physiological range
Optical non-invasive diagnostics of microcirculatory-tissue systems of the human body: questions of metrological and instrumentation provision
Optical techniques are one of the most promising non-invasive technologies for the diagnosis of medical conditions. This work is devoted to the current state of the optical non-invasive diagnostics (OND), especially about instrumentation as well as methodological and metrological provision for this technology. In some details Laser Doppler Flowmetry (LDF) and Fluorescence Spectroscopy (FS) diagnostics methods are considered. The main conclusion is that it is necessary to solve the problems of metrological support OND devices of these types. It is also important to develop a methodology based on diagnostic criteria obtained from a relationship between a number of OND methods and others
Allocation of rhodamine-loaded nanocapsules from blood circulatory system to adjacent tissues assessed in vivo by fluorescence spectroscopy
Modern fluorescent modalities play an important role in the functional diagnostic of various physiological processes in living tissues. Utilizing the fluorescence spectroscopy approach we observe the circulation of fluorescent-labelled nanocapsules with rhodamine tetramethylrhodamine in a microcirculatory blood system. The measurements were conducted transcutaneously on the surface of healthy Wistar rat thighs in vivo. The administration of the preparation capsule suspension with a rhodamine concentration of 5 mg kg−1 of the animal weight resulted in a two-fold increase of fluorescence intensity relative to the baseline level. The dissemination of nanocapsules in the adjacent tissues via the circulatory system was observed and assessed quantitatively. The approach can be used for the transdermal assessment of rhodamine-loaded capsules in vivo
Noninvasive control of rhodamine-loaded capsules distribution in vivo
Using fluorescence spectroscopy system with fibre-optical probe, we investigated the dynamics of propagation and circulation in the microcirculatory system of experimental nanocapsules fluorescent-labelled (rhodamine TRITC) nanocapsules. The studies were carried out in clinically healthy Wistar rats. The model animals were divided into control group and group received injections of the nanocapsules. The fluorescent measurements conducted transcutaneously on the thigh surface. The administration of the preparation with the rhodamine concentration of 5 mg/kg of animal weight resulted in twofold increase of fluorescence intensity by reference to the baseline level. As a result of the study, it was concluded that fluorescence spectroscopy can be used for transdermal measurements of the rhodamine-loaded capsules in vivo
Wavelength-tunable, GaSb-based, cascaded type-I quantum-well laser emitting over a range of 300 nm
We present a wavelength-tunable, external-cavity GaSb-based quantum-well laser operating near 3.2 μm. The laser setup consists of an intra-cavity grating in Littman-Metcalf configuration and a cascade pumped GaSb-based gain chip with a narrow-ridge waveguide. The narrow-ridge waveguide has a length of 2 mm and width of 7.5 μm. Cascade pumping is realized with three type-I quantum-wells, using one quantum-well per cascade stage. The laser provides continuous-wave output powers up to 8 mW and slope-efficiencies of 13 % at room temperature. Laser operation is demonstrated over a wavelength range of more than 300 nm, using continuous-wave and pulsed operation regimes
Novel measure for the calibration of laser Doppler flowmetry devices
The metrological basis for optical non-invasive diagnostic devices is an unresolved issue. A major challenge for laser Doppler flowmetry (LDF) is the need to compare the outputs from individual devices and various manufacturers to identify variations useful in clinical diagnostics. The most common methods for instrument calibration are simulants or phantoms composed of colloids of light-scattering particles which simulate the motion of red blood cells based on Brownian motion. However, such systems have limited accuracy or stability and cannot calibrate for the known rhythmic components of perfusion (0.0095-1.6 Hz). To solve this problem, we propose the design of a novel technique based on the simulation of moving particles using an electromechanical transducer, in which a precision piezoelectric actuator is used (e.g., P-602.8SL with maximum movement less than 1 mm). In this system, Doppler shift is generated in the layered structure of different solid materials with different optical light diffusing properties. This comprises a fixed, light transparent upper plane-parallel plate and an oscillating fluoroplastic (PTFE) disk. Preliminary studies on this experimental setup using the LDF-channel of a "LAKK-M" system demonstrated the detection of the linear portion (0-10 Hz with a maximum signal corresponding to Doppler shift of about 20 kHz) of the LDF-signal from the oscillating frequency of the moving layer. The results suggest the possibility of applying this technique for the calibration of LDF devices
- …