67 research outputs found

    Isothermal Recombinase Polymerase amplification (RPA) of Schistosoma haematobium DNA and oligochromatographic lateral flow detection

    Get PDF
    © 2015 Rosser et al. Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. The attached file is the published version of the article

    Head-to-head comparison of nasal and nasopharyngeal sampling using SARS-CoV-2 rapid antigen testing in Lesotho

    Get PDF
    OBJECTIVES: To assess the real-world diagnostic performance of nasal and nasopharyngeal swabs for SD Biosensor STANDARD Q COVID-19 Antigen Rapid Diagnostic Test (Ag-RDT). METHODS: Individuals >/=5 years with COVID-19 compatible symptoms or history of exposure to SARS-CoV-2 presenting at hospitals in Lesotho received two nasopharyngeal and one nasal swab. Ag-RDT from nasal and nasopharyngeal swabs were performed as point-of-care on site, the second nasopharyngeal swab used for polymerase chain reaction (PCR) as the reference standard. RESULTS: Out of 2198 participants enrolled, 2131 had a valid PCR result (61% female, median age 41 years, 8% children), 84.5% were symptomatic. Overall PCR positivity rate was 5.8%. The sensitivity for nasopharyngeal, nasal, and combined nasal and nasopharyngeal Ag-RDT result was 70.2% (95%CI: 61.3-78.0), 67.3% (57.3-76.3) and 74.4% (65.5-82.0), respectively. The respective specificity was 97.9% (97.1-98.4), 97.9% (97.2-98.5) and 97.5% (96.7-98.2). For both sampling modalities, sensitivity was higher in participants with symptom duration </= 3days versus /= 80%. The high agreement between nasal and nasopharyngeal sampling suggests that for Ag-RDT nasal sampling is a good alternative to nasopharyngeal sampling

    Evaluation of ground-level and space-borne sensor as tools in monitoring nitrogen nutrition status in immature and mature oil palm

    Get PDF
    Monitoring nitrogen (N) in oil palm is crucial for the production sustainability. The objective of this study is to examine the capability of visible (Vis), near infrared (NIR) and a combination of Vis and NIR (Vis + NIR) spectral indices acquired from different sensors for predicting foliar N content of different palm age groups. The N treatments varied from 0 to 2 kg per palm, subjected according to immature, young mature and prime mature classes. The Vis + NIR indices from the ground level-sensor that is green + red + NIR (G + R + NIR) was the best index for predicting N for immature palms (R2 = 0.91), while Vis indices blue + red (B + R) and Green Red Index from the space-borne sensor were significantly useful for N assessment of young and prime mature palms (R2 = 0.70 and 0.50), respectively. The application of vegetation indices for monitoring N status of oil palm is beneficial to examine extensive plantation areas

    First International External Quality Assessment Study on Molecular and Serological Methods for Yellow Fever Diagnosis

    Get PDF
    Objective: We describe an external quality assurance (EQA) study designed to assess the efficiency and accurateness of molecular and serological methods used by expert laboratories performing YF diagnosis. Study Design: For molecular diagnosis evaluation, a panel was prepared of 14 human plasma samples containing specific RNA of different YFV strains (YFV-17D, YFV South American strain [Brazil], YFV IvoryC1999 strain), and specificity samples containing other flaviviruses and negative controls. For the serological panel, 13 human plasma samples with anti-YFVspecific antibodies against different strains of YFV (YFV-17D strain, YFV IvoryC1999 strain, and YFV Brazilian strain), as well as specificity and negative controls, were included. Results: Thirty-six laboratories from Europe, the Americas, Middle East, and Africa participated in these EQA activities. Only 16% of the analyses reported met all evaluation criteria with optimal performance. Serial dilutions of YFV-17D showed that in general the methodologies reported provided a suitable sensitivity. Failures were mainly due to the inability to detect wild-type strains or the presence of false positives. Performance in the serological diagnosis varied, mainly depending on the methodology used. Anti-YFV IgM detection was not performed in 16% of the reports using IIF or ELISA techniques, although it is preferable for the diagnosis of YFV acute infections. A good sensitivity profile was achieved in general; however, in the detection of IgM antibodies a lack of sensitivity of anti-YFV antibodies against the vaccine strain 17D was observed, and of the anti-YFV IgG antibodies against a West African strain. Neutralization assays showed a very good performance; however, the unexpected presence of false positives underlined the need of improving the running protocols. Conclusion: This EQA provides information on each laboratory’s efficacy of RT-PCR and serological YFV diagnosis techniques. The results indicate the need for improving serological and molecular diagnosis techniques and provide a follow-up of the diagnostic profiles

    Enhancing Preparedness for Arbovirus Infections with a One Health Approach: The Development and Implementation of Multisectoral Risk Assessment Exercises

    Get PDF
    10 Pág.One Health is receiving attention for arbovirus infection prevention and control and for defining national "intersectoral" priorities. Increasing awareness of intersectoral priorities through multisectorial risk assessments (MRA) is promising, where data are not systematically shared between sectors. Towards this aim, the MediLabSecure project organized three MRA exercises (hereby called exercises): one on West Nile virus, one on Crimean-Congo haemorrhagic fever, and one on Rift Valley fever, assessing the added value of this approach.The authors acknowledge the active participation of the members of MediLabSecure network to the MRA exercises. The MediLabSecure project was supported by the European Commission (DEVCO: IFS/21010/23/_194 & IFS/2018/402-247). The funding body was not involved in the design of the study, in collection, analysis, and interpretation of data, and in writing the manuscript.Peer reviewe

    Twelve lateral flow immunoassays (LFAs) to detect SARS-CoV-2 antibodies.

    Get PDF
    BACKGROUND: There are an abundance of commercially available lateral flow assays (LFAs) that detect antibodies to SARS-CoV-2. Whilst these are usually evaluated by the manufacturer, externally performed diagnostic accuracy studies to assess performance are essential. Herein we present an evaluation of 12 LFAs. METHODS: Sera from 100 SARS-CoV-2 reverse-transcriptase polymerase chain reaction (RT-PCR) positive participants were recruited through the FASTER study. A total of 105 pre-pandemic sera from participants with other infections were included as negative samples. RESULTS: At presentation sensitivity against RT-PCR ranged from 37.4 to 79% for IgM/IgG, 30.3-74% for IgG, and 21.2-67% for IgM. Sensitivity for IgM/IgG improved ≥ 21 days post symptom onset for 10/12 tests. Specificity ranged from 74.3 to 99.1% for IgM/IgG, 82.9-100% for IgG, and 75.2-98% for IgM. Compared to the EuroImmun IgG enzyme-linked immunosorbent assay (ELISA), sensitivity and specificity ranged from 44.6 to 95.4% and 85.4-100%, respectively. CONCLUSION: There are many LFAs available with varied sensitivity and specificity. Understanding the diagnostic accuracy of these tests will be vital as we come to rely more on the antibody status of a person moving forward, and as such manufacturer-independent evaluations are crucial

    Multicenter Diagnostic Evaluation of a Novel Coronavirus Antigen Lateral Flow Test among Symptomatic Individuals in Brazil and the United Kingdom

    Get PDF
    The COVID-19 pandemic has led to the commercialization of many antigen-based rapid diagnostic tests (Ag-RDTs), requiring independent evaluations. This report describes the clinical evaluation of the Novel Coronavirus 2019-nCoV Antigen Test (Colloidal Gold) (Beijing Hotgen Biotech Co., Ltd.), at two sites within Brazil and one in the United Kingdom. The collected samples (446 nasal swabs from Brazil and 246 nasopharyngeal samples from the UK) were analyzed by the Ag-RDT and compared to reverse transcription-quantitative PCR (RT-qPCR). Analytical evaluation of the Ag-RDT was performed using direct culture supernatants of SARS-CoV-2 strains from the wild-type (B.1), Alpha (B.1.1.7), Delta (B.1.617.2), Gamma (P.1), and Omicron (B.1.1.529) lineages. An overall sensitivity and specificity of 88.2% (95% confidence interval [CI], 81.3 to 93.3) and 100.0% (95% CI, 99.1 to 100.0), respectively, were obtained for the Brazilian and UK cohorts. The analytical limit of detection was determined as 1.0 × 103 PFU/mL (Alpha), 2.5 × 102 PFU/mL (Delta), 2.5 × 103 PFU/mL (Gamma), and 1.0 × 103 PFU/mL (Omicron), giving a viral copy equivalent of approximately 2.1 × 104 copies/mL, 9.0 × 105 copies/mL, 1.7 × 106 copies/mL, and 1.8 × 105 copies/mL for the Ag-RDT, respectively. Overall, while a higher sensitivity was claimed by the manufacturers than that found in this study, this evaluation finds that the Ag-RDT meets the WHO minimum performance requirements for sensitivity and specificity of COVID-19 Ag-RDTs. This study illustrates the comparative performance of the Hotgen Ag-RDT across two global settings and considers the different approaches in evaluation methods

    Les sols observés par les satellites : exemples de modèles et d'applications

    No full text
    Les différences de réflectance spectrale entre sols permettent de les discriminer plus ou moins bien depuis l'espace, selon les capteurs utilisés. La réflectance est une donnée essentielle en télédétection, mais sa mesure était jusqu'à présent réalisée surtout en laboratoire. Les relations entre la réflectance spectrale, la couleur et la composition des sols passés en revue dans cet article montrent l'intérêt de son étude d'un point de vue pédologique. Les nouveaux instruments de terrain que sont les spectroradiomètres portables permettent de mesurer facilement cette grandeur in situ, améliorant la caractérisation spectrale pour les applications à la télédétection. Mais ils permettent aussi de mesurer la couleur des sols et l'intensité d'absorptions caractéristiques de certains composants tels les oxy-hydroxydes de fer, ouvrant de nouvelles perspectives dans l'étude des couvertures pédologiques en place et dans le suivi de leur évolution. Deux essais de faisabilité illustrent cet apport potentiel de la spectroradiométrie aux études pédologiques de terrain. (Résumé d'auteur
    corecore