1,095 research outputs found

    Low noise buffer amplifiers and buffered phase comparators for precise time and frequency measurement and distribution

    Get PDF
    Extremely low noise, high performance, wideband buffer amplifiers and buffered phase comparators were developed. These buffer amplifiers are designed to distribute reference frequencies from 30 KHz to 45 MHz from a hydrogen maser without degrading the hydrogen maser's performance. The buffered phase comparators are designed to intercompare the phase of state of the art hydrogen masers without adding any significant measurement system noise. These devices have a 27 femtosecond phase stability floor and are stable to better than one picosecond for long periods of time. Their temperature coefficient is less than one picosecond per degree C, and they have shown virtually no voltage coefficients

    Quality Control of DNA Polymerase α

    Get PDF

    Multisystem proteinopathy due to a homozygous p.Arg159His VCP mutation : a tale of the unexpected

    Get PDF
    ObjectiveTo assess the clinical, radiologic, myopathologic, and proteomic findings in a patient manifesting a multisystem proteinopathy due to a homozygous valosin-containing protein gene (VCP) mutation previously reported to be pathogenic in the heterozygous state.MethodsWe studied a 36-year-old male index patient and his father, both presenting with progressive limb-girdle weakness. Muscle involvement was assessed by MRI and muscle biopsies. We performed whole-exome sequencing and Sanger sequencing for segregation analysis of the identified p.Arg159His VCP mutation. To dissect biological disease signatures, we applied state-of-the-art quantitative proteomics on muscle tissue of the index case, his father, 3 additional patients with VCP-related myopathy, and 3 control individuals.ResultsThe index patient, homozygous for the known p.Arg159His mutation in VCP, manifested a typical VCP-related myopathy phenotype, although with a markedly high creatine kinase value and a relatively early disease onset, and Paget disease of bone. The father exhibited a myopathy phenotype and discrete parkinsonism, and multiple deceased family members on the maternal side of the pedigree displayed a dementia, parkinsonism, or myopathy phenotype. Bioinformatic analysis of quantitative proteomic data revealed the degenerative nature of the disease, with evidence suggesting selective failure of muscle regeneration and stress granule dyshomeostasis.ConclusionWe report a patient showing a multisystem proteinopathy due to a homozygous VCP mutation. The patient manifests a severe phenotype, yet fundamental disease characteristics are preserved. Proteomic findings provide further insights into VCP-related pathomechanisms

    The full spectrum of ethical issues in pediatric genome-wide sequencing: a systematic qualitative review

    Get PDF
    Background The use of genome-wide sequencing in pediatric medicine and research is growing exponentially. While this has many potential benefits, the normative and empirical literature has highlighted various ethical issues. There have not been, however, any systematic reviews of these issues. The aim of this systematic review is to determine systematically the spectrum of ethical issues that is raised for stakeholders in in pediatric genome-wide sequencing. Methods A systematic review in PubMed and Google Books (publications in English or German between 2004 and 2021) was conducted. Further references were identified via reference screening. Data were analyzed and synthesized using qualitative content analysis. Ethical issues were defined as arising when a relevant normative principle is not adequately considered or when two principles come into conflict. Results Our literature search retrieved 3175 publications of which 143 were included in the analysis. Together these mentioned 106 ethical issues in pediatric genome-wide sequencing, categorized into five themes along the pediatric genome-wide sequencing lifecycle. Most ethical issues identified in relation to genome-wide sequencing typically reflect ethical issues that arise in general genetic testing, but they are often amplified by the increased quantity of data obtained, and associated uncertainties. The most frequently discussed ethical aspects concern the issue of unsolicited findings. Conclusion Concentration of the debate on unsolicited findings risks overlooking other ethical challenges. An overarching difficulty presents the terminological confusion: both with regard to both the test procedure/ the scope of analysis, as well as with the topic of unsolicited findings. It is important that the genetics and ethics communities together with other medical professions involved work jointly on specific case related guidelines to grant the maximum benefit for the care of the children, while preventing patient harm and disproportionate overload of clinicians and the healthcare system by the wealth of available options and economic incentives to increase testing

    Size-resolved aerosol emission factors and new particle formation/growth activity occurring in Mexico City during the MILAGRO 2006 Campaign

    Get PDF
    Measurements of the aerosol size distribution from 11 nm to 2.5 microns were made in Mexico City in March 2006, during the MILAGRO (Megacity Initiative: Local and Global Research Observations) field campaign. Observations at the urban supersite, referred to as T0, could often be characterized by morning conditions with high particle mass concentrations, low mixing heights, and highly correlated particle number and CO<sub>2</sub> concentrations, indicative that particle number is controlled by primary emissions. Average size-resolved and total number- and volume-based emission factors for combustion sources impacting T0 have been determined using a comparison of peak sizes in particle number and CO<sub>2</sub> concentration. Peaks are determined by subtracting the measured concentration from a calculated baseline concentration time series. The number emission and volume emission factors for particles from 11 nm to 494 nm are 1.56 × 10<sup>15</sup> particles, and 9.48 × 10<sup>11</sup> cubic microns per kg of carbon, respectively. The uncertainty of the number emission factor is approximately plus or minus 50 %. The mode of the number emission factor was between 25 and 32 nm, while the mode of the volume factor was between 0.25 and 0.32 microns. These emission factors are reported as log normal model parameters and are compared with multiple emission factors from the literature. In Mexico City in the afternoon, the CO<sub>2</sub> concentration drops during ventilation of the polluted layer, and the coupling between CO<sub>2</sub> and particle number breaks down, especially during new particle formation events when particle number is no longer controlled by primary emissions. Using measurements of particle number and CO<sub>2</sub> taken aboard the NASA DC-8, the determined primary emission factor was applied to the Mexico City Metropolitan Area (MCMA) plume to quantify the degree of secondary particle formation in the plume; the primary emission factor accounts for less than 50 % of the total particle number and the surplus particle count is not correlated with photochemical age. Primary particle volume and number in the size range 0.1–2 μm are similarly too low to explain the observed volume distribution. Contrary to the case for number, the apparent secondary volume increases with photochemical age. The size distribution of the apparent increase, with a mode at ~250 nm, is reported

    Risk of recurrence after a first unprovoked venous thromboembolism : external validation of the Vienna Prediction Model with pooled individual patient data

    Get PDF
    Background: In order to stratify patients with a first unprovoked venous thromboembolism (VTE) according to their recurrence risk and to identify those who would actually benefit from indefinite anticoagulation, three prediction models have been developed so far; none of them has been yet externally validated. Objective: To externally validate the Vienna Prediction Model (VPM), a prediction guide for estimating the recurrence risk after a first unprovoked VTE developed through Cox modeling and including sex, D-dimer and index VTE site as predictors. Patients/Methods: Nine hundred and four patients pooled from five prospective studies evaluating the prognostic value of D-dimer for VTE recurrence served as the validation cohort. The validity of the VPM in stratifying patients according to their relative recurrence risk (discrimination) and in predicting the absolute recurrence risk (calibration) was tested with survival analysis methods. Results: The ability of the VPM to distinguish patients' risk for recurrent VTE in the validation cohort was at least as good as in the original cohort, with a calibration slope of 1.17 (95% confidence interval 0.71-1.64; P\ua0=\ua00.456 for the hypothesis of a significant difference from 1), and a c-statistic of 0.626 (vs. 0.651 in the original derivation cohort). The VPM absolute predictions in terms of cumulative rates tended to underestimate the observed recurrence rates at 12\ua0months. Conclusions: By using a pooled individual patient database as a validation cohort, we confirmed the ability of the VPM to stratify patients with a first unprovoked VTE according to their risk of recurrence

    Bio-electrospraying and aerodynamically assisted bio-jetting the model eukaryotic Dictyostelium discoideum: assessing stress and developmental competency post treatment

    Get PDF
    Bio-electrospraying (BES) and aerodynamically assisted bio-jetting (AABJ) have recently been established as important novel biospray technologies for directly manipulating living cells. To elucidate their potential in medical and clinical sciences, these bio-aerosol techniques have been subjected to increasingly rigorous investigations. In parallel to these studies, we wish to introduce these unique biotechnologies for use in the basic biological sciences, for handling a wide range of cell types and systems, thus increasing the range and the scope of these techniques for modern research. Here, the authors present the analysis of the new use of these biospray techniques for the direct handling of the simple eukaryotic biomedical model organism Dictyostelium discoideum. These cells are widely used as a model for immune cell chemotaxis and as a simple model for development. We demonstrate that AABJ of these cells did not cause cell stress, as defined by the stress-gene induction, nor affect cell development. Furthermore, although BES induced the increased expression of one stress-related gene (gapA), this was not a generalized stress response nor did it affect cell development. These data suggest that these biospray techniques can be used to directly manipulate single cells of this biomedical model without inducing a generalized stress response or perturbing later development

    Localizing Defects in Multithreaded Programs by Mining Dynamic Call Graphs

    Get PDF
    Writing multithreaded software for multicore computers confronts many developers with the difficulty of finding parallel programming errors. In the past, most parallel debugging techniques have concentrated on finding race conditions due to wrong usage of synchronization constructs. A widely unexplored issue, however, is that a wrong usage of non-parallel programming constructs may also cause wrong parallel application behavior. This paper presents a novel defect-localization technique for multithreaded shared-memory programs that is based on analyzing execution anomalies. Compared to race detectors that report just on wrong synchronization, this method can detect a wider range of defects affecting parallel execution. It works on a condensed representation of the call graphs of multithreaded applications and employs data-mining techniques to locate a method containing a defect. Our results from controlled application experiments show that we found race conditions, but also other programming errors leading to incorrect parallel program behavior. On average, our approach reduced in our benchmark the amount of code to be inspected to just 7.1% of all methods
    corecore