1,096 research outputs found

    Transoral, retromolar, para-tonsillar approach to the styloid process in 6 patients with Eagle's syndrome

    Get PDF
    Objectives: Eagle's syndrome is caused by an elongated or mineralised styloid process and characterised by facial and pharyngeal pain, odynophagia and dysphagia. Diagnosis is based on clinical findings. However radiologic imaging, like panoramic radiograph, helps to confirm the diagnosis. There are different treatments of the Eagle's syndrome. Anti-inflammatory medication (carbamazepime, corticosteroids) and/or surgical interventions are established. The aim of the different surgical techniques is to resect the elongated styloid process near the skull base. Study Design: A transoral, retromolar, para-tonsillar approach was performed to expose and resect the elongated calcified styloid process in a consecutive series of six patients. The use of different angled ring curettes, generally used in hypophysis surgery, facilitated the preparation of the styloid process through the surrounding tissue to the skull base, without a compromise to the surrounding tissue. Clinical examinations were performed pre- and postoperatively (3 month and after 1 year after surgery) in all patients. Results: No intra- or postoperative complications were observed. The hypophysis ring curettes facilitated the preparation of the styloid process to the skull base. Conclusions: The transoral, retromolar, para-tonsillar approach is a secure and fast method to resect an elongated symptomatic styloid process. Side effects of the classical transoral trans-tonsillar approach did not occur

    Comparison of Self-Reported and Device-Based Measured Physical Activity Using Measures of Stability, Reliability, and Validity in Adults and Children

    Get PDF
    Quantification of physical activity (PA) depends on the type of measurement and analysis method making it difficult to compare adherence to PA guidelines. Therefore, test-retest reliability, validity, and stability for self-reported (i.e., questionnaire and diary) and device-based measured (i.e., accelerometry with 10/60 s epochs) PA was compared in 32 adults and 32 children from the SMARTFAMILY study to examine if differences in these measurement tools are systematic. PA was collected during two separate measurement weeks and the relationship for each quality criteria was analyzed using Spearman correlation. Results showed the highest PA values for questionnaires followed by 10-s and 60-s epochs measured by accelerometers. Levels of PA were lowest when measured by diary. Only accelerometry demonstrated reliable, valid, and stable results for the two measurement weeks, the questionnaire yielded mixed results and the diary showed only a few significant correlations. Overall, higher correlations for the quality criteria were found for moderate than for vigorous PA and the results differed between children and adults. Since the differences were not found to be systematic, the choice of measurement tools should be carefully considered by anyone working with PA outcomes, especially if vigorous PA is the parameter of interest

    Key facets to build up eHealth and mHealth interventions to enhance physical activity, sedentary behavior and nutrition in healthy subjects – an umbrella review

    Get PDF
    Background Electronic (eHealth) and mobile (mHealth) health interventions can provide a large coverage, and are promising tools to change health behavior (i.e. physical activity, sedentary behavior and healthy eating). However, the determinants of intervention effectiveness in primary prevention has not been explored yet. Therefore, the objectives of this umbrella review were to evaluate intervention effectiveness, to explore the impact of pre-defined determinants of effectiveness (i.e. theoretical foundations, behavior change techniques, social contexts or just-in-time adaptive interventions), and to provide recommendations for future research and practice in the field of primary prevention delivered via e/mHealth technology. Methods PubMed, Scopus, Web of Science and the Cochrane Library were searched for systematic reviews and meta-analyses (reviews) published between January 1990 and May 2020. Reviews reporting on e/mHealth behavior change interventions in physical activity, sedentary behavior and/or healthy eating for healthy subjects (i.e. subjects without physical or physiological morbidities which would influence the realization of behaviors targeted by the respective interventions) were included if they also investigated respective theoretical foundations, behavior change techniques, social contexts or just-in-time adaptive interventions. Included studies were ranked concerning their methodological quality and qualitatively synthesized. Results The systematic search revealed 11 systematic reviews and meta-analyses of moderate quality. The majority of original research studies within the reviews found e/mHealth interventions to be effective, but the results showed a high heterogeneity concerning assessment methods and outcomes, making them difficult to compare. Whereas theoretical foundation and behavior change techniques were suggested to be potential positive determinants of effective interventions, the impact of social context remains unclear. None of the reviews included just-in-time adaptive interventions. Conclusion Findings of this umbrella review support the use of e/mHealth to enhance physical activity and healthy eating and reduce sedentary behavior. The general lack of precise reporting and comparison of confounding variables in reviews and original research studies as well as the limited number of reviews for each health behavior constrains the generalization and interpretation of results. Further research is needed on study-level to investigate effects of versatile determinants of e/mHealth efficiency, using a theoretical foundation and additionally explore the impact of social contexts and more sophisticated approaches like just-in-time adaptive interventions. Trial registration The protocol for this umbrella review was a priori registered with PROSPERO: CRD42020147902

    Sleep quality, valence, energetic arousal, and calmness as predictors of device-based measured physical activity during a three-week mHealth intervention

    Get PDF
    Physical inactivity is known to be a risk factor for several noncommunicable diseases and has a high prevalence in today’s society. Therefore, it is crucial to understand the psychological factors associated with physical activity (PA). Recent developments in the field of ambulatory assessment and technological advances are promising to enhance our understanding of this relationship by analyzing longitudinal data within- and between-persons. These analyses can reveal important factors to design behavior change interventions to enhance PA. Therefore, this study used an ecological momentary assessment during the 3-week intervention period in the SMARTFAMILY2.0 trial and aimed to investigate whether valence, calmness, energetic arousal, and sleep quality predict daily steps and moderate to vigorous PA. Overall, 49 adults (35–60 years) and 40 children (5–19 years) were included in this analysis and self-rated their mental state within our smartphone application while also wearing a hip-worn accelerometer for 21 consecutive days (996 days included) during the intervention period. Multilevel analyses were conducted to predict daily PA while considering covariables (e.g., child/adult and non-wear time) both within- and between-persons. The results indicated that higher than average ratings of a person’s valence and energetic arousal on one day predicted increased PA while higher than average calmness predicted decreased PA at the same day within this person. Sleep quality and between-person effects of the affective states showed no clear associations to PA. Overall, these results showed that within- person associations of valence, calmness, and energetic arousal should be considered when designing PA interventions for both children and adults. The influence of sleep quality, as well as between-person effects, should be further explored by future studies

    Sleep quality, valence, energetic arousal, and calmness as predictors of device-based measured physical activity during a three-week mHealth intervention – An ecological momentary assessment study within the SMARTFAMILY trial = Schlafqualität, Valenz, energetische Erregung und Ruhe als Prädiktoren für gerätegestützt gemessene körperliche Aktivität während einer dreiwöchigen mHealth-Intervention – Eine ökologische Momentaufnahme-Studie im Rahmen der SMARTFAMILY-Studie

    Get PDF
    Physical inactivity is known to be a risk factor for several noncommunicable diseases and has a high prevalence in today’s society. Therefore, it is crucial to understand the psychological factors associated with physical activity (PA). Recent developments in the field of ambulatory assessment and technological advances are promising to enhance our understanding of this relationship by analyzing longitudinal data within- and between-persons. These analyses can reveal important factors to design behavior change interventions to enhance PA. Therefore, this study used an ecological momentary assessment during the 3‑week intervention period in the SMARTFAMILY2.0 trial and aimed to investigate whether valence, calmness, energetic arousal, and sleep quality predict daily steps and moderate to vigorous PA. Overall, 49 adults (35–60 years) and 40 children (5–19 years) were included in this analysis and self-rated their mental state within our smartphone application while also wearing a hip-worn accelerometer for 21 consecutive days (996 days included) during the intervention period. Multilevel analyses were conducted to predict daily PA while considering covariables (e.g., child/adult and non-wear time) both within- and between-persons. The results indicated that higher than average ratings of a person’s valence and energetic arousal on one day predicted increased PA while higher than average calmness predicted decreased PA at the same day within this person. Sleep quality and between-person effects of the affective states showed no clear associations to PA. Overall, these results showed that within-person associations of valence, calmness, and energetic arousal should be considered when designing PA interventions for both children and adults. The influence of sleep quality, as well as between-person effects, should be further explored by future studies

    Sensor-based fall risk assessment in older adults with or without cognitive impairment: a systematic review

    Get PDF
    Background Higher age and cognitive impairment are associated with a higher risk of falling. Wearable sensor technology may be useful in objectively assessing motor fall risk factors to improve physical exercise interventions for fall prevention. This systematic review aims at providing an updated overview of the current research on wearable sensors for fall risk assessment in older adults with or without cognitive impairment. Therefore, we addressed two specific research questions: 1) Can wearable sensors provide accurate data on motor performance that may be used to assess risk of falling, e.g., by distinguishing between faller and non-faller in a sample of older adults with or without cognitive impairment?; and 2) Which practical recommendations can be given for the application of sensor-based fall risk assessment in individuals with CI? A systematic literature search (July 2019, update July 2020) was conducted using PubMed, Scopus and Web of Science databases. Community-based studies or studies conducted in a geriatric setting that examine fall risk factors in older adults (aged ≥60 years) with or without cognitive impairment were included. Predefined inclusion criteria yielded 16 cross-sectional, 10 prospective and 2 studies with a mixed design. Results Overall, sensor-based data was mainly collected during walking tests in a lab setting. The main sensor location was the lower back to provide wearing comfort and avoid disturbance of participants. The most accurate fall risk classification model included data from sit-to-walk and walk-to-sit transitions collected over three days of daily life (mean accuracy = 88.0%). Nine out of 28 included studies revealed information about sensor use in older adults with possible cognitive impairment, but classification models performed slightly worse than those for older adults without cognitive impairment (mean accuracy = 79.0%). Conclusion Fall risk assessment using wearable sensors is feasible in older adults regardless of their cognitive status. Accuracy may vary depending on sensor location, sensor attachment and type of assessment chosen for the recording of sensor data. More research on the use of sensors for objective fall risk assessment in older adults is needed, particularly in older adults with cognitive impairment

    Characterisation Studies of Silicon Photomultipliers

    Full text link
    This paper describes an experimental setup that has been developed to measure and characterise properties of Silicon Photomultipliers (SiPM). The measured SiPM properties are of general interest for a multitude of potential applications and comprise the Photon Detection Efficiency (PDE), the voltage dependent cross-talk and the after-pulse probabilities. With the described setup the absolute PDE can be determined as a function of wavelength covering a spectral range from 350 to 1000nm. In addition, a method is presented which allows to study the pixel uniformity in terms of the spatial variations of sensitivity and gain. The results from various commercially available SiPMs - three HAMAMATSU MPPCs and one SensL SPM - are presented and compared.Comment: 11 pages, 21 figures, submitted to Nuclear Instruments and Methods in Physics Research Section

    Lifetime vs. rate capability: Understanding the role of FEC and VC in high-energy Li-ion batteries with nano-silicon anodes

    Get PDF
    Fluoroethylene carbonate (FEC) and vinylene carbonate (VC) are the most frequently used electrolyte components to enhance the lifetime of anode materials in Li-ion batteries, but for silicon it is still ambiguous when FEC or VC is more beneficial. Herein, a nanostructured silicon/carbon anode derived from low-cost HSiCl3 is tailored by the rational choice of the electrolyte component, to obtain an anode material outperforming current complex silicon structures. We demonstrate highly reversible areal capacities of up to 5 mA h/cm2 at 4.4 mg/cm2 mass loading, a specific capacity of 1280 mA h/gElectrode, a capacity retention of 81% after 500 deep-discharge cycles versus lithium metal and successful full-cell tests with high-voltage cathodes meeting the requirements for real application. Electrochemical impedance spectroscopy and post-mortem investigation provide new insights in tailoring the interfacial properties of silicon-based anodes for high performance anode materials based on an alloying mechanism with large volume changes. The role of fluorine in the FEC-derived interfacial layer is discussed in comparison with the VC-derived layer and possible degradation mechanisms are proposed. We believe that this study gives a valuable understanding and provides new strategies on the facile use of additives for highly reversible silicon anodes in Li-ion batteries.Fil: Jaumann, Tony. Ifw Dresden; AlemaniaFil: Balach, Juan Manuel. Ifw Dresden; AlemaniaFil: Langklotz, Ulrike. Technische Universität Dresden; AlemaniaFil: Sauchuk, Viktar. Fraunhofer Institute for Ceramic Materials and Systems; AlemaniaFil: Fritsch, Marco. Fraunhofer Institute for Ceramic Materials and Systems; AlemaniaFil: Michaelis, Alexander. Technische Universität Dresden; AlemaniaFil: Teltevskij, Valerij. Leibniz Institute for Solid State and Materials Research; AlemaniaFil: Mikhailova, Daria. Leibniz Institute for Solid State and Materials Research; AlemaniaFil: Oswald, Steffen. Leibniz Institute for Solid State and Materials Research; AlemaniaFil: Klose, Markus. Leibniz Institute for Solid State and Materials Research; Alemania. Technische Universität Dresden; AlemaniaFil: Stephani, Guenter. Branch Lab Dresden. Fraunhofer Institute for Manufacturing Technology and Advanced Materials; ArgentinaFil: Hauser, Ralf. Branch Lab Dresden. Fraunhofer Institute for Manufacturing Technology and Advanced Materials; ArgentinaFil: Eckert, Jürgen. Technische Universität Dresden; Alemania. Leibniz Institute for Solid State and Materials Research; AlemaniaFil: Giebeler, Lars. Leibniz Institute for Solid State and Materials Research; Alemania. Technische Universität Dresden; Alemani
    • …
    corecore