61 research outputs found

    Gender, school and academic year differences among Spanish university students at high-risk for developing an eating disorder: An epidemiologic study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The aim of this study was to assess the magnitude of the university population at high-risk of developing an eating disorder and the prevalence of unhealthy eating attitudes and behaviours amongst groups at risk; gender, school or academic year differences were also explored.</p> <p>Methods</p> <p>A cross-sectional study based on self-report was used to screen university students at high-risk for an eating disorder. The sample size was of 2551 university students enrolled in 13 schools between the ages of 18 and 26 years. The instruments included: a social-demographic questionnaire, the Eating Disorders Inventory (EDI), the Body Shape Questionnaire (BSQ), the Symptom Check List 90-R (SCL-90-R), and the Self-Esteem Scale (RSE). The sample design is a non-proportional stratified sample by academic year and school. The prevalence rate was estimated controlling academic year and school. Logistic regression analysis was used to investigate adjusted associations between gender, school and academic year.</p> <p>Results</p> <p>Female students presented unhealthy weight-control behaviours as dieting, laxatives use or self-induced vomiting to lose weight than males. A total of 6% of the females had a BMI of 17.5 or less or 2.5% had amenorrhea for 3 or more months. In contrast, a higher proportion of males (11.6%) reported binge eating behaviour. The prevalence rate of students at high-risk for an eating disorder was 14.9% (11.6–18) for males and 20.8% (18.7–22.8) for females, according to an overall cut-off point on the EDI questionnaire. Prevalence rates presented statistically significant differences by gender (p < 0.001) but not by school or academic year.</p> <p>Conclusion</p> <p>The prevalence of eating disorder risk in university students is high and is associated with unhealthy weight-control practices, similar results have been found in previous studies using cut-off points in questionnaires. These results may be taken into account to encourage early detection and a greater awareness for seeking treatment in order to improve the diagnosis, among students on university campuses.</p

    Surfing the spectrum - what is on the horizon?

    Get PDF
    Diagnostic imaging techniques have evolved with technological advancements - but how far? The objective of this article was to explore the electromagnetic spectrum to find imaging techniques which may deliver diagnostic information of equal, or improved, standing to conventional radiographs and to explore any developments within radiography which may yield improved diagnostic data. A comprehensive literature search was performed using Medline, Web of Knowledge, Science Direct and PubMed Databases. Boolean Operators were used and key-terms included (not exclusively): terahertz, X-ray, ultraviolet, visible, infra-red, magnetic resonance, dental, diagnostic, caries and periodontal. Radiographic techniques are primarily used for diagnostic imaging in dentistry, and continued developments in X-ray imaging include: phase contrast, darkfield and spectral imaging. Other modalities have potential application, for example, terahertz, laser doppler and optical techniques, but require further development. In particular, infra-red imaging has regenerated interest with caries detection in vitro, due to improved quality and accessibility of cameras. Non-ionising imaging techniques, for example, infra-red, are becoming more commensurate with traditional radiographic techniques for caries detection. Nevertheless, X-rays continue to be the leading diagnostic image for dentists, with improved diagnostic potential for lower radiation dose becoming a reality

    Volumetric Breast-Density Measurement Using Spectral Photon-Counting Tomosynthesis: First Clinical Results

    No full text
    Measurements of breast density have the potential to improve the efficiency and reduce the cost of screening mammography through personalized screening. Breast density has traditionally been evaluated from the dense area in a mammogram, but volumetric assessment methods, which measure the volumetric fraction of fibro-glandular tissue in the breast, are potentially more consistent and physically sound. The purpose of the present study is to evaluate a method for measuring the volumetric breast density using photon-counting spectral tomosynthesis. The performance of the method was evaluated using phantom measurements and clinical data from a small population (n=18). The precision was determined to 2.4 percentage points (pp) of volumetric breast density. Strong correlations were observed between contralateral (R2=0.95) and ipsilateral () breast-density measurements. The measured breast density was anti-correlated to breast thickness, as expected, and exhibited a skewed distribution in the range [3.7%, 55%] and with a median of 18%. We conclude that the method yields promising results that are consistent with expectations. The relatively high precision of the method may enable novel applications such as treatment monitoring. QC 20210108</p

    Design and application of a structured phantom for detection performance comparison between breast tomosynthesis and digital mammography

    No full text
    This paper introduces and applies a structured phantom with inserted target objects for the comparison of detection performance of digital breast tomosynthesis (DBT) against 2D full field digital mammography (FFDM). The phantom consists of a 48 mm thick breast-shaped polymethyl methacrylate (PMMA) container filled with water and PMMA spheres of different diameters. Three-dimensionally (3D) printed spiculated masses (diameter range: 3.8-9.7 mm) and non-spiculated masses (1.6-6.2 mm) along with microcalcifications (90-250 µm) were inserted as targets. Reproducibility of the phantom application was studied on a single system using 30 acquisitions. Next, the phantom was evaluated on five different combined FFDM & DBT systems and target detection was compared for FFDM and DBT modes. Ten phantom images in both FFDM and DBT modes were acquired on these 5 systems using automatic exposure control. Five readers evaluated target detectability. Images were read with the four-alternative forced-choice (4-AFC) paradigm, with always one segment including a target and 3 normal background segments. The percentage of correct responses (PC) was assessed based on 10 trials of each reader for each object type, size and imaging modality. Additionally, detection threshold diameters at 62.5 PC were assessed via non-linear regression fitting of the psychometric curve. The reproducibility study showed no significant differences in PC values. Evaluation of target detection in FFDM showed that microcalcification detection thresholds ranged between 110 and 118 µm and were similar compared to the detection in DBT (range of 106-158 µm). In DBT, detection of both mass types increased significantly (p  =  0.0001 and p  =  0.0002 for non-spiculated and spiculated masses respectively) compared to FFDM, achieving almost 100% detection for all spiculated mass diameters. In conclusion, a structured phantom with inserted targets was able to show evidence for detectability differences between FFDM and DBT modes for five commercial systems. This phantom has potential for application in task-based assessment at acceptance and commissioning testing of DBT systems.journal_title: Physics in Medicine and Biology article_type: paper article_title: Design and application of a structured phantom for detection performance comparison between breast tomosynthesis and digital mammography copyright_information: © 2017 Institute of Physics and Engineering in Medicine date_received: 2016-08-19 date_accepted: 2016-12-15 date_epub: 2017-01-10status: publishe
    • …