521 research outputs found
Acuerdo de asociación Centroamérica-Unión Europea: evaluación utilizando equilibrio general computable y equilibrio parcial
Incluye Bibliografí
Environmentally friendly analysis of emerging contaminants by pressurized hot water extraction-stir bar sorptive extraction-derivatization and gas chromatography-mass spectrometry
This work describes the development, optimiza-
tion, and validation of a new method for the simultaneous
determination of a wide range of pharmaceuticals (beta-
blockers, lipid regulators
...
) and personal care products
(fragrances, UV filters, phthalates
...
) in both aqueous and
solid environmental matrices. Target compounds were
extracted from sediments using pressurized hot water ex-
traction followed by stir bar sorptive extraction. The first
stage was performed at 1,500 psi during three static extrac-
tion cycles of 5 min each after optimizing the extraction
temperature (50
–
150 °C) and addition of organic modifiers
(% methanol) to water, the extraction solvent. Next, aqueous
extracts and water samples were processed using polydime-
thylsiloxane bars. Several parameters were optimized for
this technique, including extraction and desorption time,
ionic strength, presence of organic modifiers, and pH. Fi-
nally, analytes were extracted from the bars by ultrasonic
irradiation using a reduced amount of solvent (0.2 mL) prior
to derivatization and gas chromatography
–
mass spectrome-
try analysis. The optimized protocol uses minimal amounts
of organic solvents (<10 mL/sample) and time (
≈
8 h/sam-
ple) compared to previous ex
isting methodologies. Low
standard deviation (usually below 10 %) and limits of de-
tection (sub-ppb) vouch for the applicability of the method-
ology for the analysis of target compounds at trace levels.
Once developed, the method was applied to determin
The High-Acceptance Dielectron Spectrometer HADES
HADES is a versatile magnetic spectrometer aimed at studying dielectron
production in pion, proton and heavy-ion induced collisions. Its main features
include a ring imaging gas Cherenkov detector for electron-hadron
discrimination, a tracking system consisting of a set of 6 superconducting
coils producing a toroidal field and drift chambers and a multiplicity and
electron trigger array for additional electron-hadron discrimination and event
characterization. A two-stage trigger system enhances events containing
electrons. The physics program is focused on the investigation of hadron
properties in nuclei and in the hot and dense hadronic matter. The detector
system is characterized by an 85% azimuthal coverage over a polar angle
interval from 18 to 85 degree, a single electron efficiency of 50% and a vector
meson mass resolution of 2.5%. Identification of pions, kaons and protons is
achieved combining time-of-flight and energy loss measurements over a large
momentum range. This paper describes the main features and the performance of
the detector system
Ministries of Health and the Stewardship of Health Evidence
This chapter describes how Ministries of Health have been mandated to act as stewards of populations’ health according to the World Health Organization. We argue that this mandate extends to them having (at least partial) responsibility for ensuring relevant evidence informs policy decisions. Yet this requires consideration of the evidence advisory systems serving Ministry needs, particularly whether or how such systems work to provide relevant information in a timely manner to key decision points in the policy process. Insights from our six cases are presented to illustrate the structural and practical differences which exist between evidence advisory systems and how, at certain times, key health decisions may in fact lie outside ministerial authority. These divergent experiences highlight a range of analytical challenges when considering the provision of evidence to inform health decisions from an institutional perspective
Ultrahigh-energy neutrino follow-up of Gravitational Wave events GW150914 and GW151226 with the Pierre Auger Observatory
On September 14, 2015 the Advanced LIGO detectors observed their first
gravitational-wave (GW) transient GW150914. This was followed by a second GW
event observed on December 26, 2015. Both events were inferred to have arisen
from the merger of black holes in binary systems. Such a system may emit
neutrinos if there are magnetic fields and disk debris remaining from the
formation of the two black holes. With the surface detector array of the Pierre
Auger Observatory we can search for neutrinos with energy above 100 PeV from
point-like sources across the sky with equatorial declination from about -65
deg. to +60 deg., and in particular from a fraction of the 90% confidence-level
(CL) inferred positions in the sky of GW150914 and GW151226. A targeted search
for highly-inclined extensive air showers, produced either by interactions of
downward-going neutrinos of all flavors in the atmosphere or by the decays of
tau leptons originating from tau-neutrino interactions in the Earth's crust
(Earth-skimming neutrinos), yielded no candidates in the Auger data collected
within s around or 1 day after the coordinated universal time (UTC)
of GW150914 and GW151226, as well as in the same search periods relative to the
UTC time of the GW candidate event LVT151012. From the non-observation we
constrain the amount of energy radiated in ultrahigh-energy neutrinos from such
remarkable events.Comment: Published version. Added journal reference and DOI. Added Report
Numbe
Multi-resolution anisotropy studies of ultrahigh-energy cosmic rays detected at the Pierre Auger Observatory
We report a multi-resolution search for anisotropies in the arrival
directions of cosmic rays detected at the Pierre Auger Observatory with local
zenith angles up to and energies in excess of 4 EeV ( eV). This search is conducted by measuring the angular power spectrum
and performing a needlet wavelet analysis in two independent energy ranges.
Both analyses are complementary since the angular power spectrum achieves a
better performance in identifying large-scale patterns while the needlet
wavelet analysis, considering the parameters used in this work, presents a
higher efficiency in detecting smaller-scale anisotropies, potentially
providing directional information on any observed anisotropies. No deviation
from isotropy is observed on any angular scale in the energy range between 4
and 8 EeV. Above 8 EeV, an indication for a dipole moment is captured; while no
other deviation from isotropy is observed for moments beyond the dipole one.
The corresponding -values obtained after accounting for searches blindly
performed at several angular scales, are in the case of
the angular power spectrum, and in the case of the needlet
analysis. While these results are consistent with previous reports making use
of the same data set, they provide extensions of the previous works through the
thorough scans of the angular scales.Comment: Published version. Added journal reference and DOI. Added Report
Numbe
Calibration of the Logarithmic-Periodic Dipole Antenna (LPDA) Radio Stations at the Pierre Auger Observatory using an Octocopter
An in-situ calibration of a logarithmic periodic dipole antenna with a
frequency coverage of 30 MHz to 80 MHz is performed. Such antennas are part of
a radio station system used for detection of cosmic ray induced air showers at
the Engineering Radio Array of the Pierre Auger Observatory, the so-called
Auger Engineering Radio Array (AERA). The directional and frequency
characteristics of the broadband antenna are investigated using a remotely
piloted aircraft (RPA) carrying a small transmitting antenna. The antenna
sensitivity is described by the vector effective length relating the measured
voltage with the electric-field components perpendicular to the incoming signal
direction. The horizontal and meridional components are determined with an
overall uncertainty of 7.4^{+0.9}_{-0.3} % and 10.3^{+2.8}_{-1.7} %
respectively. The measurement is used to correct a simulated response of the
frequency and directional response of the antenna. In addition, the influence
of the ground conductivity and permittivity on the antenna response is
simulated. Both have a negligible influence given the ground conditions
measured at the detector site. The overall uncertainties of the vector
effective length components result in an uncertainty of 8.8^{+2.1}_{-1.3} % in
the square root of the energy fluence for incoming signal directions with
zenith angles smaller than 60{\deg}.Comment: Published version. Updated online abstract only. Manuscript is
unchanged with respect to v2. 39 pages, 15 figures, 2 table
Azimuthal asymmetry in the risetime of the surface detector signals of the Pierre Auger Observatory
The azimuthal asymmetry in the risetime of signals in Auger surface detector
stations is a source of information on shower development. The azimuthal
asymmetry is due to a combination of the longitudinal evolution of the shower
and geometrical effects related to the angles of incidence of the particles
into the detectors. The magnitude of the effect depends upon the zenith angle
and state of development of the shower and thus provides a novel observable,
, sensitive to the mass composition of cosmic rays
above eV. By comparing measurements with predictions from
shower simulations, we find for both of our adopted models of hadronic physics
(QGSJETII-04 and EPOS-LHC) an indication that the mean cosmic-ray mass
increases slowly with energy, as has been inferred from other studies. However,
the mass estimates are dependent on the shower model and on the range of
distance from the shower core selected. Thus the method has uncovered further
deficiencies in our understanding of shower modelling that must be resolved
before the mass composition can be inferred from .Comment: Replaced with published version. Added journal reference and DO
- …