18 research outputs found

    Evaluation of global load sharing and shear-lag models to describe mechanical behavior in partially lacerated tendons

    Get PDF
    The mechanical effect of a partial thickness tear or laceration of a tendon is analytically modeled under various assumptions and results are compared with previous experimental data from porcine flexor tendons. Among several fibril-level models considered, a shear-lag model that incorporates fibril–matrix interaction and a fibril–fibril interaction defined by the contact area of the interposed matrix best matched published data for tendons with shallow cuts (less than 50% of the cross-sectional area). Application of this model to the case of many disrupted fibrils is based on linear superposition and is most successful when more fibrils are incorporated into the model. An equally distributed load sharing model for the fraction of remaining intact fibrils was inadequate in that it overestimates the strength for a cut less than half of the tendon's cross-sectional area. In a broader sense, results imply that shear-lag contributes significantly to the general mechanical behavior of tendons when axial loads are nonuniformly distributed over a cross section, although the predominant hierarchical level and microstructural mediators for this behavior require further inquiry.Peer ReviewedPostprint (published version

    Ultrasound Echo is Related to Stress and Strain in Tendon

    Full text link
    The mechanical behavior of tendons has been well studied in vitro. A noninvasive method to acquire mechanical data would be highly beneficial. Elastography has been a promising method of gathering in vivo tissue mechanical behavior, but it has inherent limitations. This study presents acoustoelasticity as an alternative ultrasound-based method of measuring tendon stress and strain by reporting a relationship between ultrasonic echo intensity (B-mode ultrasound image brightness) and mechanical behavior of tendon in vitro. Porcine digital flexor tendons were cyclically loaded in a mechanical testing system while an ultrasonic echo response was recorded. We report that echo intensity closely follows the applied cyclic strain pattern in time with higher strain protocols resulting in larger echo intensity changes. We also report that echo intensity is related nonlinearly to stress and nearly linearly to strain. This indicates that ultrasonic echo intensity is related to the mechanical behavior in a loaded tissue by an acoustoelastic response, as previously described in homogeneous, nearly incompressible materials. Acoustoelasticity is therefore able to relate strain-dependent stiffness and stress to the reflected echo, even in the processed B-mode signals reflected from viscoelastic and inhomogeneous material such as tendon, and is a promising metric to acquire in vivo mechanical data noninvasively

    Crown Preservation of the Mandibular First Molar Tooth Impacts the Strength and Stiffness of Three Non-Invasive Jaw Fracture Repair Constructs in Dogs

    Get PDF
    Repairing mandibular body fractures present unique challenges not encountered when repairing long bones. Large tooth roots and the presence of the inferior alveolar neurovascular bundle limit safe placement for many types of orthopedic implants. Use of noninvasive fracture repair methods have increasingly become popular and have proven safe and effective at achieving bone healing. Noninvasive fixation constructs have not been tested in dogs using cantilevered bending. Furthermore noninvasive fracture repair constructs have not been tested at the location of a common fracture location- the mandibular first molar tooth (M1). The objectives of this study were to test the strength and stiffness of three noninvasive mandibular fracture repair constructs and to characterize the impact that tooth crown preservation has on fixation strength for fractures occurring at the M1 location. Specimens were assigned to three treatment groups: (1) composite only, (2) interdental wiring and composite and (3) transmucosal fixation screw and composite. For each pair of mandibles, one mandible received crown amputation at the alveolar margin to simulate the effect of crown loss on fixation strength and stiffness. Regardless of the status of crown presence, interdental wiring and composite demonstrated the greatest bending stiffness and load to failure. With the crown removed, interdental wiring and composite was significantly stronger compared to other treatments. All fixation constructs were stiffer when the tooth crown was preserved. In fractures at this location, retaining the tooth crown of M1 significantly increases stiffness of interdental wiring with composite and transmucosal screw with composite constructs. If the crown of M1 was removed, interdental wiring and composite was significantly stronger than the other two forms of fixation

    Quantification of Collagen Organization Using Fractal Dimensions and Fourier Transforms

    Full text link
    Collagen fibers and fibrils that comprise tendons and ligaments are disrupted or damaged during injury. Fibrillogenesis during healing produces a matrix that is initially quite disorganized, but remodels over time to resemble, but not replicate, the original roughly parallel microstructure. Quantification of these changes is traditionally a laborious and subjective task. In this work we applied two automated techniques, fast Fourier transformation (FFT) and fractal dimension analysis (FA) to quantify the organization of collagen fibers or fibrils. Using multi-photon images of collagen fibers obtained from rat ligament we showed that for healing ligaments, FA differentiates more clearly between the different time-points during healing. Using scanning electron microscopy images of overstretched porcine flexor tendon, we showed that combining FFT and FA measures distinguishes the damaged and undamaged groups more clearly than either method separately

    Interleukin-1 Receptor Antagonist Modulates Inflammation and Scarring After Ligament Injury

    Full text link
    Ligaments have limited regenerative potential and as a consequence, repair is protracted and results in a mechanically inferior tissue more scar-like than native ligament. We previously reported that a single injection of interleukin-1 receptor antagonist (IL-1Ra) delivered at the time of injury, decreased the number of M2 macrophage-associated inflammatory cytokines. Based on these results, we hypothesized that IL-1Ra administered after injury and closer to peak inflammation (as would occur clinically), would more effectively decrease inflammation and thereby improve healing. Since IL-1Ra has a short half-life, we also investigated the effect of multiple injections. The objective of this study was to elucidate healing of a medial collateral ligament (MCL) with either a single IL-1Ra injection delivered one day after injury or with multiple injections of IL-1Ra on days 1, 2, 3, and 4. One day after MCL injury, rats received either single or multiple injections of IL-1Ra or PBS. Tissue was then collected at days 5 and 11. Both single and multiple IL-1Ra injections reduced inflammatory cytokines, but did not change mechanical behavior. A single injection of IL-1Ra also reduced the number of myofibroblasts and increased type I procollagen. Multiple IL-1Ra doses provided no additive response and, in fact, reduced the M2 macrophages. Based on these results, a single dose of IL-1Ra was better at reducing the MCL-derived inflammatory cytokines compared to multiple injections. The changes in type I procollagen and myofibroblasts further suggest a single injection of IL-1Ra enhanced repair of the ligament but not sufficiently to improve functional behavior
    corecore