9,698 research outputs found

    Direct test of time-reversal symmetry in the entangled neutral kaon system at a ϕ\phi-factory

    Get PDF
    We present a novel method to perform a direct T (time reversal) symmetry test in the neutral kaon system, independent of any CP and/or CPT symmetry tests. This is based on the comparison of suitable transition probabilities, where the required interchange of in out states for a given process is obtained exploiting the Einstein-Podolsky-Rosen correlations of neutral kaon pairs produced at a ϕ\phi-factory. In the time distribution between the two decays, we compare a reference transition like the one defined by the time ordered decays (,ππ)(\ell^-,\pi\pi) with the T -conjugated one defined by (3π0,+)(3\pi^0, \ell^+). With the use of this and other T conjugated comparisons, the KLOE-2 experiment at DAΦ\PhiNE could make a significant test

    Are collapse models testable with quantum oscillating systems? The case of neutrinos, kaons, chiral molecules

    Full text link
    Collapse models provide a theoretical framework for understanding how classical world emerges from quantum mechanics. Their dynamics preserves (practically) quantum linearity for microscopic systems, while it becomes strongly nonlinear when moving towards macroscopic scale. The conventional approach to test collapse models is to create spatial superpositions of mesoscopic systems and then examine the loss of interference, while environmental noises are engineered carefully. Here we investigate a different approach: We study systems that naturally oscillate --creating quantum superpositions-- and thus represent a natural case-study for testing quantum linearity: neutrinos, neutral mesons, and chiral molecules. We will show how spontaneous collapses affect their oscillatory behavior, and will compare them with environmental decoherence effects. We will show that, contrary to what previously predicted, collapse models cannot be tested with neutrinos. The effect is stronger for neutral mesons, but still beyond experimental reach. Instead, chiral molecules can offer promising candidates for testing collapse models.Comment: accepted by NATURE Scientific Reports, 12 pages, 1 figures, 2 table

    Theoretical analysis of aliasing noises in cold atom Mach-Zehnder interferometers

    Get PDF
    We present a theoretical analysis of aliasing noises that might appear in cold atom Mach-Zehnder interferometers used for the measurement of various physical quantities. We focus more specifically on single cold atom gyroscopes. To evaluate the level of aliasing noises, we have developed a model based on the power spectral densities of the different identified noise sources as input parameters and which makes use of a servo-loop to realize a precise measurement of the rotation rate. The model allows one to take into account different modes of operation, like a continuous as well as a pulsed or even a multi-ball operation. For monokinetic atoms, we show that the intermodulation noise can be completely filtered out with a continuous mode of operation and an optimum modulation scheme for any modulation frequency but also with a pulsed operation however only for specific launching frequencies. In the case of a real continuous atomic beam having a velocity distribution, it comes out that a high attenuation can be reached which indicates clearly the potential stability improvement that can be expected from a continuous operatio

    Aplicación de elementos finitos en la predicción del factor de intensidad de esfuerzos para fisuras en modo abertura

    Get PDF
    Se expone la importancia del criterio KIC en Fractomecánica y su campo de aplicabilidad. Se indican Las Limitaciones de la formulación analítica. Se proponen dos criterios de evaluación de K1 en base al Método de Elementos Finitos: el Criterio del Promedio de Valores y el Criterio del Intercepto. Se entregan resultados para ambos criterios aplicados a tres especímenes finitos, incluyendo una evaluación de cada criterio

    A large sample study of spin relaxation and magnetometric sensitivity of paraffin-coated Cs vapor cells

    Get PDF
    We have manufactured more than 250 nominally identical paraffin-coated Cs vapor cells (30 mm diameter bulbs) for multi-channel atomic magnetometer applications. We describe our dedicated cell characterization apparatus. For each cell we have determined the intrinsic longitudinal, \sGamma{01}, and transverse, \sGamma{02}, relaxation rates. Our best cell shows \sGamma{01}/2\pi\approx 0.5 Hz, and \sGamma{02}/2\pi\approx 2 Hz. We find a strong correlation of both relaxation rates which we explain in terms of reservoir and spin exchange relaxation. For each cell we have determined the optimal combination of rf and laser powers which yield the highest sensitivity to magnetic field changes. Out of all produced cells, 90% are found to have magnetometric sensitivities in the range of 9 to 30 fTHz. Noise analysis shows that the magnetometers operated with such cells have a sensitivity close to the fundamental photon shot noise limit

    Quantum marking and quantum erasure for neutral kaons

    Full text link
    Entangled K0 anti-K0 pairs are shown to be suitable to discuss extensions and tests of Bohr's complementarity principle through the quantum marking and quantum erasure techniques suggested by M. O. Scully and K. Druehl [Phys. Rev. A 25, 2208 (1982)]. Strangeness oscillations play the role of the traditional interference pattern linked to wave-like behaviour, whereas the distinct propagation in free space of the K_S and K_L components mimics the two possible interferometric paths taken by particle-like objects.Comment: 4 RevTeX page

    Matrix metalloproteinase-9 and tissue inhibitor of metalloproteinase-1 in diagnosis of pleural effusion of malignant origin

    Get PDF
    OBJECTIVES: The aim of the present study was to evaluate the diagnostic accuracy of matrix metalloproteinase-9 and tissue inhibitor of metalloproteinase-1 in differentiating benign from malignant exudative pleural effusions. METHODS: This is a unicentre observational study including 97 consecutive patients with exudative pleural effusions. Metalloproteinase-9, tissue inhibitor of metalloproteinase-1, lactate dehydrogenase, ferritin, carcinoembryonic antigen and carbohydrate antigen 15-3 were measured in pleural effusion and serum by enzyme-linked immunosorbent assay. The activity of metalloproteinase-9 was also evaluated by substrate zymography. The data were correlated with final diagnosis of pleural effusions to evaluate the diagnostic accuracy. RESULTS: Of the 97 eligible patients, 6 were excluded. Of the 91 patients included in the study, 70 had malignant pleural effusions and 21 had benign pleural effusions. Both in sera and pleural effusions, matrix metalloproteinase-9 (P < 0.0001), tissue inhibitor of metalloproteinase-1 (P < 0.0001) and carcinoembryonic antigen (P < 0.0001) levels were higher in neoplastic patients than in benign group. Zymography analysis showed a most prominent band at a molecular weight of 92 kDa (metalloproteinase-9) whereas a less intense band was observed at 72 kDa (metalloproteinase-2). A significant correlation was found between metalloproteinase-9 and tissue inhibitor of metalloproteinase-1 levels in pleural effusion (P < 0.0001; r = 0.8) and serum (P < 0.03; r = 0.2). Pleural effusion metalloproteinase-9 and tissue inhibitor of metalloproteinase-1 levels showed higher value of sensitivity (97 and 91%, respectively) and specificity (90 and 95%, respectively) compared with other standard markers. Serum metalloproteinase-9 and tissue inhibitor of metalloproteinase-1 levels showed similar results. Among 70 neoplastic patients, 29 had negative pleural cytology. Of these, 25 presented elevated levels of metalloproteinase-9 and tissue inhibitor of metalloproteinase-1, whereas 4 patients had elevated levels of one of the two markers. CONCLUSIONS: Our results showed that metalloproteinase-9 and tissue inhibitor of metalloproteinase-1 might be valuable markers in differentiating benign from malignant pleural effusions. Their levels are neither influenced by the histology and tumour origin nor by the presence of tumour cells in pleural effusions. Thus, their use in clinical practice could help in the selection of patients needing more invasive procedures, such as thoracoscopic biopsy
    corecore