29 research outputs found

    Vaccine breakthrough hypoxemic COVID-19 pneumonia in patients with auto-Abs neutralizing type I IFNs

    Full text link
    Life-threatening `breakthrough' cases of critical COVID-19 are attributed to poor or waning antibody response to the SARS- CoV-2 vaccine in individuals already at risk. Pre-existing autoantibodies (auto-Abs) neutralizing type I IFNs underlie at least 15% of critical COVID-19 pneumonia cases in unvaccinated individuals; however, their contribution to hypoxemic breakthrough cases in vaccinated people remains unknown. Here, we studied a cohort of 48 individuals ( age 20-86 years) who received 2 doses of an mRNA vaccine and developed a breakthrough infection with hypoxemic COVID-19 pneumonia 2 weeks to 4 months later. Antibody levels to the vaccine, neutralization of the virus, and auto- Abs to type I IFNs were measured in the plasma. Forty-two individuals had no known deficiency of B cell immunity and a normal antibody response to the vaccine. Among them, ten (24%) had auto-Abs neutralizing type I IFNs (aged 43-86 years). Eight of these ten patients had auto-Abs neutralizing both IFN-a2 and IFN-., while two neutralized IFN-omega only. No patient neutralized IFN-ss. Seven neutralized 10 ng/mL of type I IFNs, and three 100 pg/mL only. Seven patients neutralized SARS-CoV-2 D614G and the Delta variant (B.1.617.2) efficiently, while one patient neutralized Delta slightly less efficiently. Two of the three patients neutralizing only 100 pg/mL of type I IFNs neutralized both D61G and Delta less efficiently. Despite two mRNA vaccine inoculations and the presence of circulating antibodies capable of neutralizing SARS-CoV-2, auto-Abs neutralizing type I IFNs may underlie a significant proportion of hypoxemic COVID-19 pneumonia cases, highlighting the importance of this particularly vulnerable population

    COVID-19 symptoms at hospital admission vary with age and sex: results from the ISARIC prospective multinational observational study

    Get PDF
    Background: The ISARIC prospective multinational observational study is the largest cohort of hospitalized patients with COVID-19. We present relationships of age, sex, and nationality to presenting symptoms. Methods: International, prospective observational study of 60 109 hospitalized symptomatic patients with laboratory-confirmed COVID-19 recruited from 43 countries between 30 January and 3 August 2020. Logistic regression was performed to evaluate relationships of age and sex to published COVID-19 case definitions and the most commonly reported symptoms. Results: ‘Typical’ symptoms of fever (69%), cough (68%) and shortness of breath (66%) were the most commonly reported. 92% of patients experienced at least one of these. Prevalence of typical symptoms was greatest in 30- to 60-year-olds (respectively 80, 79, 69%; at least one 95%). They were reported less frequently in children (≤ 18 years: 69, 48, 23; 85%), older adults (≥ 70 years: 61, 62, 65; 90%), and women (66, 66, 64; 90%; vs. men 71, 70, 67; 93%, each P < 0.001). The most common atypical presentations under 60 years of age were nausea and vomiting and abdominal pain, and over 60 years was confusion. Regression models showed significant differences in symptoms with sex, age and country. Interpretation: This international collaboration has allowed us to report reliable symptom data from the largest cohort of patients admitted to hospital with COVID-19. Adults over 60 and children admitted to hospital with COVID-19 are less likely to present with typical symptoms. Nausea and vomiting are common atypical presentations under 30 years. Confusion is a frequent atypical presentation of COVID-19 in adults over 60 years. Women are less likely to experience typical symptoms than men

    Comparação da influência dos parâmetros industriais na microestrutura de dois aços dual-phase

    No full text
    O presente trabalho estuda a influência da temperatura intercrítica (temperatura de imersão) e tempo em galvanização a 460°C na microestrutura resultante de duas composições de aços Dual-Phase: DP980 e DP980Z. A primeira composição era produzida em duas linhas de produção da ArcelorMittal na Bélgica. A última é um novo conceito elaborado para diminuir custos com elementos de liga, visando à substituição do DP980. Através de dilatometria e metalografia foi possível investigar a microestrutura dos aços DP980 e DP980Z submetidos a cinco diferentes temperaturas de imersão e seis tempos de galvanização: 775, 790, 800, 810 e 825 °C; 0, 10, 30, 60, 300 e 600 segundos. Foi verificado que composições químicas distintas dos aços resultam em diferentes parâmetros industriais em seu processamento. O novo conceito DP980Z apresentou maior taxa de austenitização durante o recozimento intercrítico, ou seja, para uma mesma temperatura de recozimento houve maior fração de austenita transformada neste aço, e, além do mais, maior fração volumétrica de martensita foi obtida nas amostras deste aço.The present work studies the influence of soaking temperature and galvanizing time at 460 °C on the resulting microstructure of two Dual-Phase steels composition: DP 980 and DP980Z. The first steel was produced on two production lines of ArcelorMittal in Belgium. The latter is a new concept elaborated to diminish costs with alloying elements, aiming to substitute the DP980 steel. Through dilatometry and metallography, it was possible to investigate of the DP980 and DP980Z microstructure that underwent five different soaking temperatures and six galvanizing times: 775, 790, 800, 810 and 825 °C; 0, 10, 30, 60, 300 and 600 seconds. It was verified that distinct chemical compositions of the steels were the result of different industrial and processing parameters. The new concept DP980Z presented a higher austenitizing rate during the intercritical annealing process, i.e. for the same annealing temperature there was a higher fraction of transformed austenite in the steel, furthermore, higher volumetric fraction of martensite was achieved on the DP980Z samples

    Validação do método de queda de potencial para medição do comprimento de trinca em corpos de prova tipo SENB com trinca curta em ensaios de propagação de trinca por fadiga

    Get PDF
    Os ensaios de propagação de trinca por fadiga em meios corrosivos apresentam um desafio para os laboratórios, onde os métodos de medição mais utilizados (e.g. Medidor de Propagação de Trinca e Clip Gauge) para a medição do comprimento da trinca, se deterioram. O método de Queda de Potencial (QP) pode ser uma alternativa viável e de boa precisão para este propósito, porém deve ser demonstrado que o laboratório tem capacidade de obter elevada precisão e acurácia através do método. Este trabalho tem o objetivo principal de avaliar uma metodologia para a determinação do comprimento de trinca curta durante ensaios de fadiga para caracterização das propriedades de materiais utilizados como dutos de coleta na indústria do petróleo em ambientes corrosivos. Os demais objetivos são: · Consolidar o método de QP para o monitoramento do comprimento da trinca em Corpo de Prova (CP) tipo SENB com trinca curta; · Apresentar as curvas ao ar de propagação de trinca da/dN x ΔK obtidas em ensaios nos materiais 13Cr5Ni2Mo, 25Cr7Ni e API 5L X60; · Identificar melhorias no procedimento dos ensaios para elevar a precisão e acurácia das curvas de taxa de propagação de trinca. Foram realizados ensaios de propagação de trinca em três aços diferentes, isto é, inoxidáveis Supermartensítico e superdúplex e Aço Carbono, sendo registrados os dados do Medidor de Propagação de Trinca (gabarito) e da técnica de QP (método a ser avaliado). Foram validadas as equações necessárias para determinar o tamanho de trinca do CP em função da diferença de potencial transversalmente à trinca com o Medidor de Propagação de Trinca e foram apresentadas as curvas ao ar de taxa de propagação de trinca x ΔK dos materiais estudados. Foi observada uma forte correlação entre os dois métodos de medição de trinca. Acreditamos que as pequenas diferenças observadas nos valores de tamanho de trinca entre as duas técnicas se devem, principalmente à: · Efeito de tunelamento na frente da trinca, já que cada método mede a trinca em diferentes regiões do CP; · Imprecisões na distância do ponto na soldagem dos fios do multímetro (que mede o potencial para técnica de QP) à trinca. As curvas de propagação de trinca foram similares à curva de dois estágios para aços da norma BS 7910 (R ≥ 0,5) na maior parte da curva. Entretanto, em ΔK próximos a 15 MPa.m1/2 (faixa inicial de ΔK aplicado), os aços apresentaram taxas de propagação significativamente inferiores à curva da norma. Foram indicados possíveis motivos para os desvios da curva e sugeridas melhorias nos procedimentos dos ensaios para elevar a precisão e acurácia na obtenção das curvas da/dN x ΔK.Fatigue crack growth rate (FCGR) tests in corrosive environments are a challenge for laboratories, where the most used techniques (e.g. Clip Gage and Crack Propagation Sensor) for crack size measurements, deteriorate. Potential Drop (PD) technique is a high precision viable alternative, however, it must be demonstrated that the laboratory has capacity to obtain high precision and accuracy through the method. This study has the main objective of evaluate a methodology to determine the short crack size during fatigue tests to properties chacacterization of materials used as oil gathering pipes in the oil and gas industry in corrosivive environment. The other objectives are: · Consolidate the PD technique for crack size monitoring in short crack SENB specimen configurations; · Introduce the 13Cr5Ni2Mo, 25Cr7Ni and API 5L X60 crack propagation rate curves (da/dN x ΔK) tested in air; · Identify test procedures improvements to enhance precision and accuracy of FGCR test curves. FCGR tests were performed in three different steels, i.e. Supermartensitic, Superduplex and Carbon Steel, where Crack Propagation Sensor (template) and PD technique (evaluated method) data were registered. Equations to determine specimen crack size in function of the potential difference measured transversally to the crack were validated with the Crack Propagation Sensor and FCGR curves in air for the studied materials were presented. A strong correlation between both crack size measurement techniques was observed. It is believed that small differences in measured crack size between techniques are mainly due to: · The tunneling effect in the crack front, both methods measuring the crack in different specimen regions · The imprecisions in the distance of the welding point of the multimeter wires used in PD to the crack. The FCGR curves behavior were similar to the two stage curve in air (R ≥ 0.5) from BS 7910 standard for the most of the curve. However, when ΔK was close to 15 MPa.m1/2 (initial applied ΔK range), the steels presented significantly lower propagation rate compared to the standard curve. It was pointed out possible reasons for this deviation and tests procedures improvements were suggested in order to increase FCGR test precision and accuracy

    Validação do método de queda de potencial para medição do comprimento de trinca em corpos de prova tipo SENB com trinca curta em ensaios de propagação de trinca por fadiga

    Get PDF
    Os ensaios de propagação de trinca por fadiga em meios corrosivos apresentam um desafio para os laboratórios, onde os métodos de medição mais utilizados (e.g. Medidor de Propagação de Trinca e Clip Gauge) para a medição do comprimento da trinca, se deterioram. O método de Queda de Potencial (QP) pode ser uma alternativa viável e de boa precisão para este propósito, porém deve ser demonstrado que o laboratório tem capacidade de obter elevada precisão e acurácia através do método. Este trabalho tem o objetivo principal de avaliar uma metodologia para a determinação do comprimento de trinca curta durante ensaios de fadiga para caracterização das propriedades de materiais utilizados como dutos de coleta na indústria do petróleo em ambientes corrosivos. Os demais objetivos são: · Consolidar o método de QP para o monitoramento do comprimento da trinca em Corpo de Prova (CP) tipo SENB com trinca curta; · Apresentar as curvas ao ar de propagação de trinca da/dN x ΔK obtidas em ensaios nos materiais 13Cr5Ni2Mo, 25Cr7Ni e API 5L X60; · Identificar melhorias no procedimento dos ensaios para elevar a precisão e acurácia das curvas de taxa de propagação de trinca. Foram realizados ensaios de propagação de trinca em três aços diferentes, isto é, inoxidáveis Supermartensítico e superdúplex e Aço Carbono, sendo registrados os dados do Medidor de Propagação de Trinca (gabarito) e da técnica de QP (método a ser avaliado). Foram validadas as equações necessárias para determinar o tamanho de trinca do CP em função da diferença de potencial transversalmente à trinca com o Medidor de Propagação de Trinca e foram apresentadas as curvas ao ar de taxa de propagação de trinca x ΔK dos materiais estudados. Foi observada uma forte correlação entre os dois métodos de medição de trinca. Acreditamos que as pequenas diferenças observadas nos valores de tamanho de trinca entre as duas técnicas se devem, principalmente à: · Efeito de tunelamento na frente da trinca, já que cada método mede a trinca em diferentes regiões do CP; · Imprecisões na distância do ponto na soldagem dos fios do multímetro (que mede o potencial para técnica de QP) à trinca. As curvas de propagação de trinca foram similares à curva de dois estágios para aços da norma BS 7910 (R ≥ 0,5) na maior parte da curva. Entretanto, em ΔK próximos a 15 MPa.m1/2 (faixa inicial de ΔK aplicado), os aços apresentaram taxas de propagação significativamente inferiores à curva da norma. Foram indicados possíveis motivos para os desvios da curva e sugeridas melhorias nos procedimentos dos ensaios para elevar a precisão e acurácia na obtenção das curvas da/dN x ΔK.Fatigue crack growth rate (FCGR) tests in corrosive environments are a challenge for laboratories, where the most used techniques (e.g. Clip Gage and Crack Propagation Sensor) for crack size measurements, deteriorate. Potential Drop (PD) technique is a high precision viable alternative, however, it must be demonstrated that the laboratory has capacity to obtain high precision and accuracy through the method. This study has the main objective of evaluate a methodology to determine the short crack size during fatigue tests to properties chacacterization of materials used as oil gathering pipes in the oil and gas industry in corrosivive environment. The other objectives are: · Consolidate the PD technique for crack size monitoring in short crack SENB specimen configurations; · Introduce the 13Cr5Ni2Mo, 25Cr7Ni and API 5L X60 crack propagation rate curves (da/dN x ΔK) tested in air; · Identify test procedures improvements to enhance precision and accuracy of FGCR test curves. FCGR tests were performed in three different steels, i.e. Supermartensitic, Superduplex and Carbon Steel, where Crack Propagation Sensor (template) and PD technique (evaluated method) data were registered. Equations to determine specimen crack size in function of the potential difference measured transversally to the crack were validated with the Crack Propagation Sensor and FCGR curves in air for the studied materials were presented. A strong correlation between both crack size measurement techniques was observed. It is believed that small differences in measured crack size between techniques are mainly due to: · The tunneling effect in the crack front, both methods measuring the crack in different specimen regions · The imprecisions in the distance of the welding point of the multimeter wires used in PD to the crack. The FCGR curves behavior were similar to the two stage curve in air (R ≥ 0.5) from BS 7910 standard for the most of the curve. However, when ΔK was close to 15 MPa.m1/2 (initial applied ΔK range), the steels presented significantly lower propagation rate compared to the standard curve. It was pointed out possible reasons for this deviation and tests procedures improvements were suggested in order to increase FCGR test precision and accuracy

    Comparação da influência dos parâmetros industriais na microestrutura de dois aços dual-phase

    No full text
    O presente trabalho estuda a influência da temperatura intercrítica (temperatura de imersão) e tempo em galvanização a 460°C na microestrutura resultante de duas composições de aços Dual-Phase: DP980 e DP980Z. A primeira composição era produzida em duas linhas de produção da ArcelorMittal na Bélgica. A última é um novo conceito elaborado para diminuir custos com elementos de liga, visando à substituição do DP980. Através de dilatometria e metalografia foi possível investigar a microestrutura dos aços DP980 e DP980Z submetidos a cinco diferentes temperaturas de imersão e seis tempos de galvanização: 775, 790, 800, 810 e 825 °C; 0, 10, 30, 60, 300 e 600 segundos. Foi verificado que composições químicas distintas dos aços resultam em diferentes parâmetros industriais em seu processamento. O novo conceito DP980Z apresentou maior taxa de austenitização durante o recozimento intercrítico, ou seja, para uma mesma temperatura de recozimento houve maior fração de austenita transformada neste aço, e, além do mais, maior fração volumétrica de martensita foi obtida nas amostras deste aço.The present work studies the influence of soaking temperature and galvanizing time at 460 °C on the resulting microstructure of two Dual-Phase steels composition: DP 980 and DP980Z. The first steel was produced on two production lines of ArcelorMittal in Belgium. The latter is a new concept elaborated to diminish costs with alloying elements, aiming to substitute the DP980 steel. Through dilatometry and metallography, it was possible to investigate of the DP980 and DP980Z microstructure that underwent five different soaking temperatures and six galvanizing times: 775, 790, 800, 810 and 825 °C; 0, 10, 30, 60, 300 and 600 seconds. It was verified that distinct chemical compositions of the steels were the result of different industrial and processing parameters. The new concept DP980Z presented a higher austenitizing rate during the intercritical annealing process, i.e. for the same annealing temperature there was a higher fraction of transformed austenite in the steel, furthermore, higher volumetric fraction of martensite was achieved on the DP980Z samples
    corecore