85 research outputs found

    Mechanical properties of cell- and microgel bead-laden oxidized alginate-gelatin hydrogels

    Get PDF
    3D-printing technologies, such as biofabrication, capitalize on the homogeneous distribution and growth of cells inside biomaterial hydrogels, ultimately aiming to allow for cell differentiation, matrix remodeling, and functional tissue analogues. However, commonly, only the mechanical properties of the bioinks or matrix materials are assessed, while the detailed influence of cells on the resulting mechanical properties of hydrogels remains insufficiently understood. Here, we investigate the properties of hydrogels containing cells and spherical PAAm microgel beads through multi-modal complex mechanical analyses in the small- and large-strain regimes. We evaluate the individual contributions of different filler concentrations and a non-fibrous oxidized alginate-gelatin hydrogel matrix on the overall mechanical behavior in compression, tension, and shear. Through material modeling, we quantify parameters that describe the highly nonlinear mechanical response of soft composite materials. Our results show that the stiffness significantly drops for cell- and bead concentrations exceeding four million per milliliter hydrogel. In addition, hydrogels with high cell concentrations (≥6 mio ml−1) show more pronounced material nonlinearity for larger strains and faster stress relaxation. Our findings highlight cell concentration as a crucial parameter influencing the final hydrogel mechanics, with implications for microgel bead drug carrier-laden hydrogels, biofabrication, and tissue engineering

    Antibacterial 45S5 Bioglass®-based scaffolds reinforced with genipin cross-linked gelatin for bone tissue engineering

    No full text
    45S5 Bioglass® (BG) scaffolds with high porosity (>90%) were coated with genipin cross-linked gelatin (GCG) and further incorporated with poly(p-xylyleneguanidine) hydrochloride (PPXG). The obtained GCG coated scaffolds maintained the high porosity and well interconnected pore structure. A 26-fold higher compressive strength was provided to 45S5 BG scaffolds by GCG coating, which slightly retarded but did not inhibit the in vitro bioactivity of 45S5 BG scaffolds in SBF. Moreover, the scaffolds were made antibacterial against both Gram-positive and Gram-negative bacteria by using polyguanidine, i.e. PPXG, in this study. Osteoblast-like cells (MG-63) were seeded onto PPXG and GCG coated scaffolds. PPXG was biocompatible with MG-63 cells at a low concentration (10 μg mL−1). MG-63 cells were shown to attach and spread on both uncoated and GCG coated scaffolds, and the mitochondrial activity measurement indicated that GCG coating had no negative influence on the cell proliferation behavior of MG-63 cells. The developed novel antibacterial bioactive 45S5 BG-based composite scaffolds with improved mechanical properties are promising candidates for bone tissue engineering

    Cell adhesion evaluation of laser-sintered HAp and 45S5 bioactive glass coatings on micro-textured zirconia surfaces using MC3T3-E1 osteoblast-like cells

    Get PDF
    Laser texturing is a technique that has been increasingly explored for the surface modification of several materials on different applications. Laser texturing can be combined with conventional coating techniques to functionalize surfaces with bioactive properties, stimulating cell differentiation and adhesion. This study focuses on the cell adhesion of laser-sintered coatings of hydroxyapatite (HAp) and 45S5 bioactive glass (45S5 BG) on zirconia textured surfaces using MC3T3-E1 cells. For this purpose, zirconia surfaces were micro-textured via laser and then coated with HAp and 45S5 BG glass via dip coating. Afterwards, the bioactive coatings were laser sintered, and a reference group of samples was conventionally sintering. The cell adhesion characterisation was achieved by cell viability performing live/dead analysis using fluorescence stains and by SEM observations for a qualitative analysis of cell adhesion. The in vitro results showed that a squared textured pattern with 100μm width grooves functionalized with a bioactive coating presented an increase of 90% of cell viability compared to flat surfaces after 48h of incubation. The functionalized laser sintered coatings do not present significant differences in cell viability when compared to conventionally sintered coatings. Therefore, the results reveal that laser sintering of HAp and 45S5 BG coatings is a fast and attractive coating technique.publishe

    Bioactivity in silica/poly(γ-glutamic acid) sol–gel hybrids through calcium chelation

    Get PDF
    Bioactive glasses and inorganic/organic hybrids have great potential as biomedical implant materials. Sol–gel hybrids with interpenetrating networks of silica and biodegradable polymers can combine the bioactive properties of a glass with the toughness of a polymer. However, traditional calcium sources such as calcium nitrate and calcium chloride are unsuitable for hybrids. In this study calcium was incorporated by chelation to the polymer component. The calcium salt form of poly(γ-glutamic acid) (γCaPGA) was synthesized for use as both a calcium source and as the biodegradable toughening component of the hybrids. Hybrids of 40 wt.% γCaPGA were successfully formed and had fine scale integration of Ca and Si ions, according to secondary ion mass spectrometry imaging, indicating a homogeneous distribution of organic and inorganic components. 29Si magic angle spinning nuclear magnetic resonance data demonstrated that the network connectivity was unaltered with changing polymer molecular weight, as there was no perturbation to the overall Si speciation and silica network formation. Upon immersion in simulated body fluid a hydroxycarbonate apatite surface layer formed on the hybrids within 1 week. The polymer molecular weight (Mw 30–120 kDa) affected the mechanical properties of the resulting hybrids, but all hybrids had large strains to failure, >26%, and compressive strengths, in excess of 300 MPa. The large strain to failure values showed that γCaPGA hybrids exhibited non-brittle behaviour whilst also incorporating calcium. Thus calcium incorporation by chelation to the polymer component is justified as a novel approach in hybrids for biomedical materials

    Accelerated Degradation Behavior and Cytocompatibility of Pure Iron Treated with Sandblasting

    Get PDF
    Fe-based materials are of interest for use in biodegradable implants. However, their corrosion rate in the biological environment may be too slow for the targeted applications. In this work, sandblasting is applied as a successful surface treatment for increasing the degradation rate of pure iron in simulated body fluid. Two sandblasting surfaces with different roughness present various surface morphologies but similar degradation products. Electrochemistry tests revealed that sandblasted samples have a higher corrosion rate compared to that of bare iron, and even more noteworthy, the degradation rate of sandblasted samples remains significantly higher during long-term immersion tests. On the basis of our experimental results, the most plausible reasons behind the fast degradation rate are the special properties of sandblasted surfaces, including the change of surface composition (for the early stage), high roughness (occluded surface sites), and high density of dislocations. Furthermore, the cytocompatibility was studied on sandblasting surfaces using human osteoblast-like cells (MG-63) by indirect and direct contact methods. Results revealed that sandblasting treatment brings no adverse effect to the growth of MG-63 cells. This work demonstrates the significant potential of sandblasting for controlling the degradation behavior of iron-based materials for biomedical applications

    Physico-chemical modification of gelatine for the improvement of 3D printability of oxidized alginate-gelatine hydrogels towards cartilage tissue engineering

    No full text
    This work explored 3D printing to mimic the intrinsic hierarchical structure of natural articular cartilage. Alginate di-aldehyde- gelatine (ADA-GEL) hydrogel was used as ink to create hierarchically ordered scaffolds. In comparison to previously reported ADA-GEL compositions, we introduce a modified formulation featuring increased amounts of thermally modified gelatine. Gelatine was degraded by hydrolysis which resulted in tailorable printability characteristics further substantiated by rheological analysis. ADA (3.75 %w/v)-GEL (7.5 %w/v) with gelatine modified at 80 °C for 3 h could be printed in hierarchical complex structures reaching scaffold heights of over 1 cm. The hierarchical structure of the scaffolds was confirmed via µCT analysis. To examine mechanical properties as well as the suitability of the hydrogel as a proper matrix for cell seeding and encapsulation, nanoindentation was performed. Elastic moduli in the range of ~ 5 kPa were measured. Gelatine heat pre-treatment resulted in modifiable mechanical and rheological characteristics of ADA-GEL. In summary, this study demonstrates the possibility to enhance the printability of ADA-GEL hydrogels to fabricate hierarchical scaffold structures with shape stability and fidelity, without the necessity to change the initial hydrogel chemistry by the use of additives or crosslinkers, providing a valuable approach for fabrication of designed scaffolds for cartilage tissue engineering

    Synthesis and In Vitro Activity Assessment of Novel Silicon Oxycarbide-Based Bioactive Glasses

    Get PDF
    Novel bioactive glasses based on a Ca- and Mg-modified silicon oxycarbide (SiCaMgOC) were prepared from a polymeric single-source precursor, and their in vitro activity towards hydroxyapatite mineralization was investigated upon incubating the samples in simulated body fluid (SBF) at 37 °C. The as-prepared materials exhibit an outstanding resistance against devitrification processes and maintain their amorphous nature even after exposure to 1300 °C. The X-ray diffraction (XRD) analysis of the SiCaMgOC samples after the SBF test showed characteristic reflections of apatite after only three days, indicating a promising bioactivity. The release kinetics of the Ca2+ and Mg2+ and the adsorption of H+ after immersion of SiCaMgOC in simulated body fluid for different soaking times were analyzed via optical emission spectroscopy. The results show that the mechanism of formation of apatite on the surface of the SiCaMgOC powders is similar to that observed for standard (silicate) bioactive glasses. A preliminary cytotoxicity investigation of the SiOC-based bioactive glasses was performed in the presence of mouse embryonic fibroblasts (MEF) as well as human embryonic kidney cells (HEK-293). Due to their excellent high-temperature crystallization resistance in addition to bioactivity, the Ca- and Mg-modified SiOC glasses presented here might have high potential in applications related to bone repair and regeneration

    The applicability of ADA-GEL hydrogels for patient-specific cartilage replacement

    No full text

    Modernisierung des Hochgeschwindigkeits-Windkanals fuer Kaltgastests an Raketenduesenmodellen mit Einfuehrungsmessungen

    No full text
    Moisture condensating from the expanding gas in the wind tunnel makes it impossible to compute the gas-dynamical processes by adiabatic equations. The condensation is avoided using a zeolite of the Fanjasite type as a drying agent. In addition, a new heater had to be installed to realize the temperature required for the regeneration of the drying agent. Pressure distribution measurements along a flat plug model proved the efficiency of the modernization measure. Condensation effects are subdued and the Mach number is increased. (WEN)SIGLEAvailable from TIB Hannover: F97B662+a / FIZ - Fachinformationszzentrum Karlsruhe / TIB - Technische InformationsbibliothekBundesministerium fuer Bildung, Wissenschaft, Forschung und Technologie, Bonn (Germany); Deutsche Agentur fuer Raumfahrtangelegenheiten (DARA) GmbH, Bonn (Germany)DEGerman
    corecore