96 research outputs found

    Martian sub-surface ionising radiation: biosignatures and geology

    Get PDF
    The surface of Mars, unshielded by thick atmosphere or global magnetic field, is exposed to high levels of cosmic radiation. This ionising radiation field is deleterious to the survival of dormant cells or spores and the persistence of molecular biomarkers in the subsurface, and so its characterisation is of prime astrobiological interest. Here, we present modelling results of the absorbed radiation dose as a function of depth through the Martian subsurface, suitable for calculation of biomarker persistence. A second major implementation of this dose accumulation rate data is in application of the optically stimulated luminescence technique for dating Martian sediments. We present calculations of the dose-depth profile in the Martian subsurface for various scenarios: variations of surface composition (dry regolith, ice, layered permafrost), solar minimum and maximum conditions, locations of different elevation (Olympus Mons, Hellas basin, datum altitude), and increasing atmospheric thickness over geological history. We also model the changing composition of the subsurface radiation field with depth compared between Martian locations with different shielding material, determine the relative dose contributions from primaries of different energies, and discuss particle deflection by the crustal magnetic fields

    SONTRAC: an imaging spectrometer for solar neutrons

    Get PDF
    An instrument capable of unambiguously determining the energy and direction of incident neutrons has important applications in solar physics-as well as environmental monitoring and medical/radiological sciences. The SONTRAC (SOlar Neutron TRACking) instrument is designed to operate in the neutron energy range of 20-250 MeV. The measurement principle is based on non-relativistic double scatter of neutrons off ambient protons (n-p scattering) within a block of densely packed scintillating fibers. Using this double-scatter mode it is possible to uniquely determine neutron energy and direction on an event-by-event basis. A fully operational science model of such an instrument has been built using 300 μm (250 μm active) scintillating fibers. The science model consists of a 5×5×5 cm cube of orthogonal plastic scintillating fiber layers. Two orthogonal imaging chains, employing image intensifiers and CCD cameras, allow full 3-dimensional reconstruction of scattered proton particle tracks. We report the results of the science model instrument calibration using 35-65 MeV protons. The proton calibration is the first step toward understanding the instrument response to n-p scatter events. Preliminary results give proton energy resolution of 2% (6%) at 67.5 (35) MeV, and angular resolution of 2° (4.5°) at 67.5 (35) MeV. These measurements are being used to validate detailed instrument simulations that will be used to optimize the instrument design and develop quantitative estimates of science return. Based on the proton calibration, neutron energy and angular resolution for a 10×10×10 cm version of SONTRAC is expected to be ~5% an

    Martian sub-surface ionising radiation: biosignatures and geology

    Get PDF
    The surface of Mars, unshielded by thick atmosphere or global magnetic field, is exposed to high levels of cosmic radiation. This ionising radiation field is deleterious to the survival of dormant cells or spores and the persistence of molecular biomarkers in the subsurface, and so its characterisation is of prime astrobiological interest. Here, we present modelling results of the absorbed radiation dose as a function of depth through the Martian subsurface, suitable for calculation of biomarker persistence. A second major implementation of this dose accumulation rate data is in application of the optically stimulated luminescence technique for dating Martian sediments. <br><br> We present calculations of the dose-depth profile in the Martian subsurface for various scenarios: variations of surface composition (dry regolith, ice, layered permafrost), solar minimum and maximum conditions, locations of different elevation (Olympus Mons, Hellas basin, datum altitude), and increasing atmospheric thickness over geological history. We also model the changing composition of the subsurface radiation field with depth compared between Martian locations with different shielding material, determine the relative dose contributions from primaries of different energies, and discuss particle deflection by the crustal magnetic fields

    Activity standardisation of 177Lu.

    Get PDF
    <sup>177</sup> Lu decays through low-energy β <sup>-</sup> - and γ-emissions in addition to conversion and Auger electrons. To support the use of this radiopharmaceutical in Switzerland, a <sup>177</sup> Lu solution was standardised using the β-γ coincidence technique, as well as the TDCR method. The solution had no <sup>177m</sup> Lu impurity. Primary coincidence measurements, with plastic scintillators for beta detection, were carried out using both analogue and digital electronics. TDCR measurements using only defocusing were also made. Monte Carlo calculations were used to compute the detection efficiency. The coincidence measurements with both analogue and digital electronics are compatible within one standard uncertainty, but they are lower than (and discrepant with) the TDCR measurements. An ampoule of this solution was submitted to the BIPM as a contribution to the Système International de Référence

    Ionization of the Venusian atmosphere from solar and galactic cosmic rays

    Get PDF
    The atmospheres of the terrestrial planets are exposed to solar and galactic cosmic rays, the most energetic of which are capable of affecting deep atmospheric layers through extensive nuclear and electromagnetic particle cascades. In the Venusian atmosphere, cosmic rays are expected to be the dominant ionization source below ∼100 km altitude. While previous studies have considered the effect of cosmic ray ionization using approximate transport methods, we have for the first time performed full 3D Monte Carlo modelling of cosmic ray interaction with the Venusian atmosphere, including the contribution of high-Z cosmic ray ions (Z=1-28). Our predictions are similar to those of previous studies at the ionization peak near 63 km altitude, but are significantly different to these both above and below this altitude. The rate of atmospheric ionization is a fundamental atmospheric property and the results of this study have wide-reaching applications in topics including atmospheric electrical processes, cloud microphysics and atmospheric chemistry

    Comparison of codes assessing galactic cosmic radiation exposure of aircraft crew

    Get PDF
    The assessment of the exposure to cosmic radiation onboard aircraft is one of the preoccupations of bodies responsible for radiation protection. Cosmic particle flux is significantly higher onboard aircraft than at ground level and its intensity depends on the solar activity. The dose is usually estimated using codes validated by the experimental data. In this paper, a comparison of various codes is presented, some of them are used routinely, to assess the dose received by the aircraft crew caused by the galactic cosmic radiation. Results are provided for periods close to solar maximum and minimum and for selected flights covering major commercial routes in the world. The overall agreement between the codes, particularly for those routinely used for aircraft crew dosimetry, was better than ±20 % from the median in all but two cases. The agreement within the codes is considered to be fully satisfactory for radiation protection purpose

    Report on G4‐Med, a Geant4 benchmarking system for medical physics applications developed by the Geant4 Medical Simulation Benchmarking Group

    Get PDF
    Geant4 is a Monte Carlo code extensively used in medical physics for a wide range of applications, such as dosimetry, micro‐ and nano‐ dosimetry, imaging, radiation protection and nuclear medicine. Geant4 is continuously evolving, so it is crucial to have a system that benchmarks this Monte Carlo code for medical physics against reference data and to perform regression testing. To respond to these needs, we developed G4‐Med, a benchmarking and regression testing system of Geant4 for medical physics, that currently includes 18 tests. They range from the benchmarking of fundamental physics quantities to the testing of Monte Carlo simulation setups typical of medical physics applications. Both electromagnetic and hadronic physics processes and models within the pre‐built, Geant4 physics lists are tested. The tests included in G4‐Med are executed on the CERN computing infrastructure via the use of the geant‐val web application, developed at CERN for Geant4 testing. The physical observables can be compared to reference data for benchmarking and to results of previous Geant4 versions for regression testing purposes. This paper describes the tests included in G4‐Med and shows the results derived from the benchmarking of Geant4 10.5 against reference data. The results presented and discussed in this paper will aid users in tailoring physics lists to their particular application.D. Bolst acknowledges the support of the Australian Government Research Training Program Scholarship. M. A. Cort ́es-Giraldo, A. Perales, and J. M. Quesada acknowledge the financial support from the Spanish Ministry of Economy and Competitiveness under grant FPA2016-77689-C2-1-R. B. Faddegon and J. Ramos-M ́endez acknowledge partial financial support from the NIH grant U24CA215123. D. Bolst, S. Guatelli, D. Sakata, S.Incerti, and I. Kyriakou acknowledge financial support from the Australian Research Council, ARC DP170100967. S. Incerti acknowledges the financial support of CNRS through the IN2P3/MOVI Master Project and through the France-Greece PICS 8235 funding scheme. I. Kyriakou acknowledges additional financial support from the European Space Agency (Contract No. 4000126645/19/NL/BW). E. C. Simpson acknowledges financial support from the Australian Research Council under grant DP170102423. I. Sechopoulos and C. Fedon acknowledge financial support from the Susan G Komen Foundation for the Cure grant IIR13262248. S. Guatelli and D. Bolst acknowlege the use of computing resources of the Aus-tralian National Computing Infrastructure (NCI), through the NCMAS 2020 grant scheme

    Double-folding interaction for 6He + α scattering

    No full text
    info:eu-repo/semantics/publishe
    corecore