26 research outputs found
Design of the PST: A Diagnostic for 1-D Imaging of Fast Z-pinch Power Emissions RECE!PED
Fast Z-pinch technology developed on the Z machine at Sandia National Laboratones can produce up to 230 TW of thermal x-ray power for applications in inertial confinement fusion (ICF) and weapons physics experiments. During implosion, these Z-pinches develop Rayleigh-Taylor (R-T) instabilities which are very difficult to diagnose and which functionally diminish the overall pinch quality. The Power-Space-Time (PST) instrument is a newly configured diagnostic for measuring the pinch power as a function of both space and time in a Z-pinch. Placing the diagnostic at 90 degrees from the Z-pinch axis, the PST provides a new capability in collecting experimental data on R-T characteristics for making meaningful comparisons to magneto-hydrodynamic computer models. This paper is a summary of the PST diagnostic design. By slit-imaging the Z-pinch xray emissions onto a linear scintillator/fiber-optic array coupled to a streak camera system, the PST can achieve -100~m spatial resolution and -1.3 ns time resolution. Calculations indicate that a 20~m thick scintillating detection element filtered by 1000~of Al is theoretically linear in response to Plankian x-ray distributions corresponding to plasma temperatures from 40 eV to 150 eV, By calibrating this detection element to x-ray energies up to 5000 eV, the PST can provide pinch power as a function of height and time in a Z-pinch for temperatures ranging from -40 eV to -400 eV. With these system pm-meters, the PST can provide data for an experimental determination of the R-T mode number, amplitude, and growth rate during the late-time pinch implosion
Recommended from our members
Modeling a 1-D bremsstrahlung and neutron imaging array for use on Sandia`s Z machine
Inertial confinement fusion is being studied on the Z facility at Sandia National Laboratories. Z is a large z-pinch machine which can provide 20 MA of current to z-pinch loads producing {approximately}1.8 MJ of soft x-rays in less than 10 ns. Within the pinch region, decelerated electrons produce a strong source of bremsstrahlung radiation which varies from shot to shot. Additionally, a variety of ICF targets produce fusion neutrons whose intensity and distribution depend on the temperature and density of the target compression in the pinch. This paper describes the computer modeling behind the shielding design of a simple time-resolved, 1-D imaging array which can provide a time history of both the bremsstrahlung and neutron production as a function of height within the target region. It is demonstrated that by building an array of scintillator fibers separated by long, thin tungsten collimator plates, a spatial resolution of 0.254 mm at the target can be achieved. The corresponding channel-to-channel discrimination for such a design is shown to be better than 1000::1 for <4 MeV photons and 100::1 for 2.45 MeV neutrons. By coupling scintillator fibers to a fiber-optic streak camera system, the signal can also be given as a function of time with a temporal resolution of about 1.2 ns
Open data from the third observing run of LIGO, Virgo, KAGRA, and GEO
The global network of gravitational-wave observatories now includes five detectors, namely LIGO Hanford, LIGO Livingston, Virgo, KAGRA, and GEO 600. These detectors collected data during their third observing run, O3, composed of three phases: O3a starting in 2019 April and lasting six months, O3b starting in 2019 November and lasting five months, and O3GK starting in 2020 April and lasting two weeks. In this paper we describe these data and various other science products that can be freely accessed through the Gravitational Wave Open Science Center at https://gwosc.org. The main data set, consisting of the gravitational-wave strain time series that contains the astrophysical signals, is released together with supporting data useful for their analysis and documentation, tutorials, as well as analysis software packages
Recommended from our members
Axial diagnostic package for Z
The authors have developed and fielded an axial diagnostic package for the 20 MA, 100 ns, z-pinch driver Z. The package is used to diagnose dynamic hohlraum experiments which require an axial line of sight. The heart of the package is a reentrant cone originally used to diagnose ion-beam-driven hohlraums on PBFA-H. It has one diagnostic line of sight at 0 degrees, 4 at 6 degrees, and 4 at 9 degrees. In addition it has a number of viewing, alignment, and vacuum feedthrough ports. The front of the package sits approximately 5 feet from the pinch. This allows much closer proximity to the pinch, with inherently better resolution and signal, than is presently possible in viewing the pinch from the side. Debris that is preferentially directed along the axis is mitigated by two apertures for each line of sight, and by fast valves and imaging pinholes or cross slits for each diagnostic. In the initial run with this package they fielded a time resolved pinhole camera, a five-channel pinhole-apertured x-ray diode array, a bolometer, a spatially resolved time-integrated crystal spectrometer, and a spatially and temporally resolved crystal spectrometer. They present data obtained from these diagnostics in the dynamic hohlraum research conducted on Z
Recommended from our members
Cylindrical target Li-beam-driven hohlraum experiments
The authors performed a series of experiments on the Particle Beam Fusion Accelerator II (PBFA II) in May, 1994, and obtained a brightness temperature of 61 {+-} 2 eV for an ion-beam heated hohlraum. The hohlraum was a 4-mm-diameter, right-circular cylinder with a 1.5-mm-thick gold wall, a low-density CH foam fill, and a 1.5- or 3-mm-diameter diagnostic aperture in the top. The nominal parameters of the radially-incident PBFA II Li ion beam were 9 MeV peak energy ({approximately}10 MeV at the gas cell) at the target at a peak power of 2.5 {+-} 0.3 TW/cm{sup 2} and a 15 ns pulse width. Azimuthal variations in intensity of a factor of 3, with respect to the mean, were observed. Nonuniformities in thermal x-ray emission across the area of the diagnostic hole were also observed. Time-dependent hole-closure velocities were measured: the time-averaged velocity of {approximately}2 cm/{micro}s is in good agreement with sound speed estimates. Unfolded x-ray spectra and brightness temperatures as a function of time are reported and compared to simulations. Hole closure corrections are discussed with comparisons between XRD and bolometer measurements. Temperature scaling with power on target is also presented
Recommended from our members
Dynamic hohlraum experiments on SATURN
The authors have imploded a 17.5 mm diameter 120-tungsten-wire array weighing 450 {mu}g/cm onto a 4 mm diameter silicon aerogel foam weighing 650 {mu}g/cm, using the pulsed power driver SATURN. A peak current of 7.0 MA drives a 48 ns implosion to strike time followed by 8 ns of foam compression until stagnation. The tungsten strikes the foam with a 50 cm/{mu}s implosion velocity. Radiation temperatures were measured from the side and along the axis with filtered x-ray diode arrays. There is evidence of radiation trapping by the optically thick tungsten from crystal spectroscopy. The pinch is open to less than a 1 mm diameter as measured by time-resolved x-ray framing cameras. The radiation brightness temperature in the foam reaches 150 eV before the main radiation burst or stagnation
Recommended from our members
A low jitter, low cost, time-of-flight circuit
A low cost circuit has been developed for use in a neutron time-of-flight spectrometer at the Nova Laser Facility. Using a silicon charged-particle detector, amplifier and constant-fraction discriminator, timing resolution of better than 50 ps FWHM has been achieved. Using an array of many such detectors, very high data rates and precise spectra can be obtained. 3 refs., 2 figs
Recommended from our members
Target diagnostic system for the National Ignition Facility (NIF)
A review of recent progress on the design of a diagnostic system proposed for ignition target experiments on the National Ignition Facility (NIF) will be presented. This diagnostic package contains an extensive suite of optical, x-ray, gamma-ray, and neutron diagnostics that enable measurements of the performance of both direct and indirect driven NIF targets. The philosophy used in designing all of the diagnostics in the set has emphasized redundant and independent measurement of fundamental physical quantities relevant to the operation of the NIF target. A unique feature of these diagnostics is that they are being designed to be capable of operating, in the high radiation, EMP, and debris backgrounds expected on the NIF facility. The diagnostic system proposed can be categorized into three broad areas: laser characterization, hohlraum characterization, and capsule performance diagnostics. The operating principles of a representative instrument from each class of diagnostic employed in this package will be summarized and illustrated with data obtained in recent prototype diagnostic tests
Recommended from our members
High Temperature Dynamic Hohlraums on the Pulsed Power Driver Z
In the concept of the dynamic hohlraum an imploding z-pinch is optically thick to its own radiation. Radiation may be trapped inside the pinch to give a radiation temperature inside the pinch greater than that outside the pinch. The radiation is typically produced by colliding an outer Z-pinch liner onto an inner liner. The collision generates a strongly radiating shock, and the radiation is trapped by the outer liner. As the implosion continues after the collision the radiation temperature may continue to increase due to ongoing PdV (pressure times change in volume) work done by the implosion. In principal the radiation temperature may increase to the point at which the outer liner burns through, becomes optically thin, and no longer traps the radiation. One application of the dynamic hohlraum is to drive an ICF (inertial confinement fusion) pellet with the trapped radiation field. Members of the dynamic hohlraum team at Sandia National Labs have used the pulsed power driver Z (20 LMA, 100 ns) to create a dynamic hohlraum with temperature linearly ramping from 100 to 180 eV over 5 ns. On this shot zp214 a nested tungsten wire array of 4 and 2 cm diameters with masses of 2 and 1 mg imploded onto a 2.5 mg plastic annulus at 5 mm diameter. The current return can on this shot was slotted. It is likely the radiation temperature may be increased to over 200 CV by stabilizing the pinch with a solid current return can. A current return can with 9 slots imprints 9 filaments onto the imploding pinch. This degrades the optical trapping and the quality of the liner collision. A 1.6 mm diameter capsule situated inside this dynamic hohlraum of zp214 would see 15 kJ of radiation impinging on its surface before the pinch itself collapses to a 1.6 mm diameter. Dynamic hohlraum shots including pellets are scheduled to take place on Z in September of 1998
Ultralight vector dark matter search using data from the KAGRA O3GK run
International audienceAmong the various candidates for dark matter (DM), ultralight vector DM can be probed by laser interferometric gravitational wave detectors through the measurement of oscillating length changes in the arm cavities. In this context, KAGRA has a unique feature due to differing compositions of its mirrors, enhancing the signal of vector DM in the length change in the auxiliary channels. Here we present the result of a search for gauge boson DM using the KAGRA data from auxiliary length channels during the first joint observation run together with GEO600. By applying our search pipeline, which takes into account the stochastic nature of ultralight DM, upper bounds on the coupling strength between the gauge boson and ordinary matter are obtained for a range of DM masses. While our constraints are less stringent than those derived from previous experiments, this study demonstrates the applicability of our method to the lower-mass vector DM search, which is made difficult in this measurement by the short observation time compared to the auto-correlation time scale of DM