535 research outputs found

    Strategic Improvements for Gross Anatomy Web-Based Teaching

    Get PDF
    Current generations of graduate students have been immersed in technology from their early school years and have high expectations regarding digital resources. To better meet the expectations of Gross Anatomy students at our institution, electronic radiology teaching files for first-year coursework were organized into a web site. The web site was custom designed to provide material that directly correlated to the Gross Anatomy dissection and lectures. Quick links provided sets of images grouped by anatomic location. Additionally, Lab and Study Companions provided specific material for the students to review prior to and after lectures and gross dissections. Student opinions of this education resource were compared to student opinions of the prior year's digital teaching files. The new content was ranked as more user friendly (3.1 points versus 2.3 points) and more useful for learning anatomy (3.3 points versus 2.6 points). Many students reported that using the web portal was critical in helping them to better understand relationships of anatomical structures. These findings suggest that a well-organized web portal can provide a user-friendly, valuable educational resource for medical students who are studying Gross Anatomy

    Does commitment to rehabilitation influence clinical outcome of total hip resurfacing arthroplasty?

    Get PDF
    BACKGROUND: The purpose of this study was to evaluate whether compliance and rehabilitative efforts were predictors of early clinical outcome of total hip resurfacing arthroplasty. METHODS: A cross-sectional survey was utilized to collect information from 147 resurfacing patients, who were operated on by a single surgeon, regarding their level of commitment to rehabilitation following surgery. Patients were followed for a mean of 52 months (range, 24 to 90 months). Clinical outcomes and functional capabilities were assessed utilizing the Harris hip objective rating system, the SF-12 Health Survey, and an eleven-point satisfaction score. A linear regression analysis was used to determine whether there was any correlation between the rehabilitation commitment scores and any of the outcome measures, and a multivariate regression model was used to control for potentially confounding factors. RESULTS: Overall, an increased level of commitment to rehabilitation was positively correlated with each of the following outcome measures: SF-12 Mental Component Score, SF-12 Physical Component Score, Harris Hip score, and satisfaction scores. These correlations remained statistically significant in the multivariate regression model. CONCLUSIONS: Patients who were more committed to their therapy after hip resurfacing returned to higher levels of functionality and were more satisfied following their surgery

    Mid-term results and factors affecting outcome of a metal-backed unicompartmental knee design: a case series

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Controversies exist regarding the indications for unicompartmental knee arthroplasty. The objective of this study is to report the mid-term results and examine predictors of failure in a metal-backed unicompartmental knee arthroplasty design.</p> <p>Methods</p> <p>At a mean follow-up of 60 months, 80 medial unicompartmental knee arthroplasties (68 patients) were evaluated. Implant survivorship was analyzed using Kaplan-Meier method. The Knee Society objective and functional scores and radiographic characteristics were compared before surgery and at final follow-up. A Cox proportional hazard model was used to examine the association of patient's age, gender, obesity (body mass index > 30 kg/m<sup>2</sup>), diagnosis, Knee Society scores and patella arthrosis with failure.</p> <p>Results</p> <p>There were 9 failures during the follow up. The mean Knee Society objective and functional scores were respectively 49 and 48 points preoperatively and 95 and 92 points postoperatively. The survival rate was 92% at 5 years and 84% at 10 years. The mean age was younger in the failure group than the non-failure group (p < 0.01). However, none of the factors assessed was independently associated with failure based on the results from the Cox proportional hazard model.</p> <p>Conclusion</p> <p>Gender, pre-operative diagnosis, preoperative objective and functional scores and patellar osteophytes were not independent predictors of failure of unicompartmental knee implants, although high body mass index trended toward significance. The findings suggest that the standard criteria for UKA may be expanded without compromising the outcomes, although caution may be warranted in patients with very high body mass index pending additional data to confirm our results.</p> <p><b>Level of Evidence</b>: IV</p

    Botulinum toxin type A injections for the management of muscle tightness following total hip arthroplasty: a case series

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Development of hip adductor, tensor fascia lata, and rectus femoris muscle contractures following total hip arthroplasties are quite common, with some patients failing to improve despite treatment with a variety of non-operative modalities. The purpose of the present study was to describe the use of and patient outcomes of botulinum toxin injections as an adjunctive treatment for muscle tightness following total hip arthroplasty.</p> <p>Methods</p> <p>Ten patients (14 hips) who had hip adductor, abductor, and/or flexor muscle contractures following total arthroplasty and had been refractory to physical therapeutic efforts were treated with injection of botulinum toxin A. Eight limbs received injections into the adductor muscle, 8 limbs received injections into the tensor fascia lata muscle, and 2 limbs received injection into the rectus femoris muscle, followed by intensive physical therapy for 6 weeks.</p> <p>Results</p> <p>At a mean final follow-up of 20 months, all 14 hips had increased range in the affected arc of motion, with a mean improvement of 23 degrees (range, 10 to 45 degrees). Additionally all hips had an improvement in hip scores, with a significant increase in mean score from 74 points (range, 57 to 91 points) prior to injection to a mean of 96 points (range, 93 to 98) at final follow-up. There were no serious treatment-related adverse events.</p> <p>Conclusion</p> <p>Botulinum toxin A injections combined with intensive physical therapy may be considered as a potential treatment modality, especially in difficult cases of muscle tightness that are refractory to standard therapy.</p

    Are component positioning and prosthesis size associated with hip resurfacing failure?

    Get PDF
    BACKGROUND: Recent studies suggest that there is a learning curve for metal-on-metal hip resurfacing. The purpose of this study was to assess whether implant positioning changed with surgeon experience and whether positioning and component sizing were associated with implant longevity. METHODS: We evaluated the first 361 consecutive hip resurfacings performed by a single surgeon, which had a mean follow-up of 59 months (range, 28 to 87 months). Pre and post-operative radiographs were assessed to determine the inclination of the acetabular component, as well as the sagittal and coronal femoral stem-neck angles. Changes in the precision of component placement were determined by assessing changes in the standard deviation of each measurement using variance ratio and linear regression analysis. Additionally, the cup and stem-shaft angles as well as component sizes were compared between the 31 hips that failed over the follow-up period and the surviving components to assess for any differences that might have been associated with an increased risk for failure. RESULTS: Surgeon experience was correlated with improved precision of the antero-posterior and lateral positioning of the femoral component. However, femoral and acetabular radiographic implant positioning angles were not different between the surviving hips and failures. The failures had smaller mean femoral component diameters as compared to the non-failure group (44 versus 47 millimeters). CONCLUSIONS: These results suggest that there may be differences in implant positioning in early versus late learning curve procedures, but that in the absence of recognized risk factors such as intra-operative notching of the femoral neck and cup inclination in excess of 50 degrees, component positioning does not appear to be associated with failure. Nevertheless, surgeons should exercise caution in operating patients with small femoral necks, especially when they are early in the learning curve

    1.5 T augmented reality navigated interventional MRI: paravertebral sympathetic plexus injections

    Get PDF
    PURPOSE:The high contrast resolution and absent ionizing radiation of interventional magnetic resonance imaging (MRI) can be advantageous for paravertebral sympathetic nerve plexus injections. We assessed the feasibility and technical performance of MRI-guided paravertebral sympathetic injections utilizing augmented reality navigation and 1.5 T MRI scanner.METHODS:A total of 23 bilateral injections of the thoracic (8/23, 35%), lumbar (8/23, 35%), and hypogastric (7/23, 30%) paravertebral sympathetic plexus were prospectively planned in twelve human cadavers using a 1.5 Tesla (T) MRI scanner and augmented reality navigation system. MRI-conditional needles were used. Gadolinium-DTPA-enhanced saline was injected. Outcome variables included the number of control magnetic resonance images, target error of the needle tip, punctures of critical nontarget structures, distribution of the injected fluid, and procedure length.RESULTS: Augmented-reality navigated MRI guidance at 1.5 T provided detailed anatomical visualization for successful targeting of the paravertebral space, needle placement, and perineural paravertebral injections in 46 of 46 targets (100%). A mean of 2 images (range, 1–5 images) were required to control needle placement. Changes of the needle trajectory occurred in 9 of 46 targets (20%) and changes of needle advancement occurred in 6 of 46 targets (13%), which were statistically not related to spinal regions (P = 0.728 and P = 0.86, respectively) and cadaver sizes (P = 0.893 and P = 0.859, respectively). The mean error of the needle tip was 3.9±1.7 mm. There were no punctures of critical nontarget structures. The mean procedure length was 33±12 min.CONCLUSION:1.5 T augmented reality-navigated interventional MRI can provide accurate imaging guidance for perineural injections of the thoracic, lumbar, and hypogastric sympathetic plexus

    Personal non-commercial use only

    Get PDF
    ABSTRACT. Objective. Bone scintigraphy has been advocated as a useful diagnostic tool for patients with suspected osteonecrosis or in screening for multifocal disease. We evaluated the sensitivity of bone scanning relative to magnetic resonance imaging (MRI) in the diagnosis of osteonecrosis. Methods. Forty-eight patients presented with suspected osteonecrosis of the shoulder, hip, knee, or ankle. All patients underwent simultaneous (&lt; 3 months apart) bone scans and MRI studies as part of diagnostic investigations. Histological confirmation of osteonecrosis was obtained for all suspected lesions. The diagnostic result for each imaging modality was then assessed and compared. Results. All 163 (100%) histologically confirmed lesions were identified by MRI, while only 91 lesions (56%) were identified by bone scan. There was complete congruency of bone scans with MR images in only 38% of patients (18/48). Bone scanning identified 72% of lesions (47/65) in oligofocal patients (≤ 2 joints involved) compared with 45% of the lesions (44/98) in multifocal patients (≥ 3 joints involved). Sensitivity of lesions was highest for the knee and hip and lower for the shoulder and ankle. Larger and later-stage lesions had a higher bone scan sensitivity. Conclusion. Our results demonstrated the low sensitivity of bone scintigraphy for diagnosing symptomatic osteonecrosis. It is least sensitive for early-stage lesions where it might be most useful to diagnose the disease. Our study also confirms that this test is less sensitive for joints other than the hip and is also not useful as a screening tool. Our study does not support the use of bone scans as a diagnostic or screening tool for osteonecrosis

    A Postulate for Tiger Recovery: The Case of the Caspian Tiger

    Get PDF
    Recent genetic analysis has shown that the extinct Caspian Tiger (P. t. virgata) and the living Amur Tigers (P. t. altaica) of the Russian Far East are actually taxonomically synonymous and that Caspian and Amur groups historically formed a single population, only becoming separated within the last 200 years by human agency. A major conservation implication of this finding is that tigers of Amur stock might be reintroduced, not only back into the Koreas and China as is now proposed, but also through vast areas of Central Asia where the Caspian tiger once lived. However, under the current tiger conservation framework the 12 “Caspian Tiger States” are not fully involved in conservation planning. Equal recognition as “Tiger Range States” should be given to the countries where the Caspian tiger once lived and their involvement in tiger conservation planning encouraged. Today, preliminary ecological surveys show that some sparsely populated areas of Central Asia preserve natural habitat suitable for tigers. In depth assessments should be completed in these and other areas of the Caspian range to evaluate the possibility of tiger reintroductions. Because tigers are a charismatic umbrella species, both ecologically and politically, reintroduction to these landscapes would provide an effective conservation framework for the protection of many species in addition to tigers. And for today’s Amur Tigers this added range will provide a buffer against further loss of genetic diversity, one which will maintain that diversity in the face of selective pressures that can only be experienced in the wild

    A Study of Time-Dependent CP-Violating Asymmetries and Flavor Oscillations in Neutral B Decays at the Upsilon(4S)

    Get PDF
    We present a measurement of time-dependent CP-violating asymmetries in neutral B meson decays collected with the BABAR detector at the PEP-II asymmetric-energy B Factory at the Stanford Linear Accelerator Center. The data sample consists of 29.7 fb1{\rm fb}^{-1} recorded at the Υ(4S)\Upsilon(4S) resonance and 3.9 fb1{\rm fb}^{-1} off-resonance. One of the neutral B mesons, which are produced in pairs at the Υ(4S)\Upsilon(4S), is fully reconstructed in the CP decay modes J/ψKS0J/\psi K^0_S, ψ(2S)KS0\psi(2S) K^0_S, χc1KS0\chi_{c1} K^0_S, J/ψK0J/\psi K^{*0} (K0KS0π0K^{*0}\to K^0_S\pi^0) and J/ψKL0J/\psi K^0_L, or in flavor-eigenstate modes involving D()π/ρ/a1D^{(*)}\pi/\rho/a_1 and J/ψK0J/\psi K^{*0} (K0K+πK^{*0}\to K^+\pi^-). The flavor of the other neutral B meson is tagged at the time of its decay, mainly with the charge of identified leptons and kaons. The proper time elapsed between the decays is determined by measuring the distance between the decay vertices. A maximum-likelihood fit to this flavor eigenstate sample finds Δmd=0.516±0.016(stat)±0.010(syst)ps1\Delta m_d = 0.516\pm 0.016 {\rm (stat)} \pm 0.010 {\rm (syst)} {\rm ps}^{-1}. The value of the asymmetry amplitude sin2β\sin2\beta is determined from a simultaneous maximum-likelihood fit to the time-difference distribution of the flavor-eigenstate sample and about 642 tagged B0B^0 decays in the CP-eigenstate modes. We find sin2β=0.59±0.14(stat)±0.05(syst)\sin2\beta=0.59\pm 0.14 {\rm (stat)} \pm 0.05 {\rm (syst)}, demonstrating that CP violation exists in the neutral B meson system. (abridged)Comment: 58 pages, 35 figures, submitted to Physical Review

    Measurement of the Branching Fraction for B- --> D0 K*-

    Get PDF
    We present a measurement of the branching fraction for the decay B- --> D0 K*- using a sample of approximately 86 million BBbar pairs collected by the BaBar detector from e+e- collisions near the Y(4S) resonance. The D0 is detected through its decays to K- pi+, K- pi+ pi0 and K- pi+ pi- pi+, and the K*- through its decay to K0S pi-. We measure the branching fraction to be B.F.(B- --> D0 K*-)= (6.3 +/- 0.7(stat.) +/- 0.5(syst.)) x 10^{-4}.Comment: 7 pages, 1 postscript figure, submitted to Phys. Rev. D (Rapid Communications
    corecore