159 research outputs found

    Application of two-photon absorption laser induced fluorescence to validate actinometry measurements of absolute atomic oxygen number density based on improved EEDFs obtained from PIC simulations.

    Get PDF
    Actinometry is a non-invasive optical technique that allows absolute atomic oxygen density determination within a plasma provided certain conditions are met. However, the technique is sensitive to to the accuracy of the Electron Energy Distribution Function (EEDF). A Maxwellian distribution is often used for actinometry calculations, but this is typically just an approximation. A Particle in Cell (PIC) code is used to try and generate a more accurate EEDF to improve the actinometry results. To do this the electron density in the plasma is measured using a hairpin probe and compared to the electron density predicted by the PIC code. The code is adjusted to get a reasonable agreement with the hairpin probe electron densities. The corresponding EEDF from the PIC code is then used in the actinoometry model to calculate the atomic oxygen density in the plasma. The actinometry results are compared to oxygen density measurements made using Two-photon Absorption Laser Induced Fluorescence to validate the actinometry results

    Patellar and hamstring autografts are associated with different jump task loading asymmetries after ACL reconstruction

    Get PDF
    © 2019 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd After anterior cruciate ligament reconstruction (ACLR), there is a higher re-injury rate to the contralateral limb in athletes who undergo surgery using a bone-patellar-tendon-bone (BPTB) autograft than using a semitendinosus and gracilis hamstring tendon (HT) autograft. This may be influenced by differing lower-limb loading asymmetries present when athletes of each graft type return to play (RTP). The aim of this study was to compare bilateral countermovement jump (CMJ) phase-specific impulse asymmetries between athletes with BPTB and HT autografts 9 months post-ACLR, and to identify the relationship between impulse and isokinetic strength asymmetries. Male field sport athletes with a BPTB (n = 22) or HT (n = 22) autograft were tested approximately 9 months post-ACLR. An uninjured control group (n = 22) was also tested on a single occasion. Phase-specific bilateral absolute impulse asymmetries were calculated during the CMJ and compared between groups using Kruskal-Wallis and post-hoc testing. A linear regression model was used to assess the relationship between impulse asymmetries and isokinetic concentric knee extensor strength asymmetries. BPTB athletes demonstrated greater impulse asymmetries than HT athletes during the eccentric (P = 0.01) and concentric (P = 0.008) phases of the jump. Isokinetic strength asymmetry was a significant predictor of CMJ concentric impulse asymmetry in both BPTB (r2 = 0.39) and HT athletes (r2 = 0.18) but not eccentric impulse asymmetry in any group. The greater loading asymmetries demonstrated by BPTB than HT athletes 9 months after ACLR may contribute to the differing incidence rates of contralateral ACL injury. The findings suggest that graft-specific loading asymmetries should be targeted during rehabilitation prior to RTP

    Cryptosporidium and Giardia in Humans, Domestic Animals, and Village Water Sources in Rural India.

    Get PDF
    Cryptosporidium parvum and Giardia lamblia are zoonotic enteric protozoa of significant health concern where sanitation, hygiene, and water supplies are inadequate. We examined 85 stool samples from diarrhea patients, 111 pooled fecal samples by species across seven domestic animal types, and water from tube wells (N = 207) and ponds (N = 94) across 60 villages in coastal Odisha, India, for Cryptosporidium oocysts and Giardia cysts to measure occurrence, concentration/shedding, and environmental loading rates. Oocysts/cysts were detected in 12% of diarrhea patients. Detection ranged from 0% to 35% for Cryptosporidium and 0% to 67% for Giardia across animal hosts. Animal loading estimates indicate the greatest contributors of environmental oocysts/cysts in the study region are cattle. Ponds were contaminated with both protozoa (oocysts: 37%, cysts: 74%), as were tube wells (oocysts: 10%, cysts: 14%). Future research should address the public health concern highlighted from these findings and investigate the role of domestic animals in diarrheal disease transmission in this and similar settings

    Human fecal and pathogen exposure pathways in rural Indian villages and the effect of increased latrine coverage.

    Get PDF
    Efforts to eradicate open defecation and improve sanitation access are unlikely to achieve health benefits unless interventions reduce microbial exposures. This study assessed human fecal contamination and pathogen exposures in rural India, and the effect of increased sanitation coverage on contamination and exposure rates. In a cross-sectional study of 60 villages of a cluster-randomized controlled sanitation trial in Odisha, India, human and domestic animal fecal contamination was measured in community tubewells and ponds (n = 301) and via exposure pathways in homes (n = 354), using Bacteroidales microbial source tracking fecal markers validated in India. Community water sources were further tested for diarrheal pathogens (rotavirus, adenovirus and Vibrio cholerae by quantitative PCR; pathogenic Escherichia coli by multiplex PCR; Cryptosporidium and Giardia by immunomagnetic separation and direct fluorescent antibody microscopy). Exposure pathways in intervention and control villages were compared and relationships with child diarrhea examined. Human fecal markers were rarely detected in tubewells (2.4%, 95%CI: 0.3-4.5%) and ponds (5.6%, 95%CI: 0.8-10.3%), compared to homes (35.4%, 95%CI: 30.4-40.4%). In tubewells, V. cholerae was the most frequently detected pathogen (19.8%, 95%CI: 14.4-25.2%), followed by Giardia (14.8%, 95%CI: 10.0-19.7%). In ponds, Giardia was most often detected (74.5%, 95%CI: 65.7-83.3%), followed by pathogenic E. coli (48.1%, 95%CI: 34.8-61.5%) and rotavirus (44.4%, 95%CI: 34.2-54.7%). At village-level, prevalence of fecal pathogen detection in community drinking water sources was associated with elevated prevalence of child diarrhea within 6 weeks of testing (RR 2.13, 95%CI: 1.25-3.63) while within homes, higher levels of human and animal fecal marker detection were associated with increased risks of subsequent child diarrhea (P = 0.044 and 0.013, respectively). There was no evidence that the intervention, which increased functional latrine coverage and use by 27 percentage points, reduced human fecal contamination in any tested pathway, nor the prevalence of pathogens in water sources. In conclusion, the study demonstrates that (1) improved sanitation alone may be insufficient and further interventions needed in the domestic domain to reduce widespread human and animal fecal contamination observed in homes, (2) pathogens detected in tubewells indicate these sources are microbiologically unsafe for drinking and were associated with child diarrhea, (3) domestic use of ponds heavily contaminated with multiple pathogens presents an under-recognized health risk, and (4) a 27 percentage point increase in improved sanitation access at village-level did not reduce detectable human fecal and pathogen contamination in this setting

    Comparing Recent Pulsar Timing Array Results on the Nanohertz Stochastic Gravitational-wave Background

    Get PDF
    The Australian, Chinese, European, Indian, and North American pulsar timing array (PTA) collaborations recently reported, at varying levels, evidence for the presence of a nanohertz gravitational-wave background (GWB). Given that each PTA made different choices in modeling their data, we perform a comparison of the GWB and individual pulsar noise parameters across the results reported from the PTAs that constitute the International Pulsar Timing Array (IPTA). We show that despite making different modeling choices, there is no significant difference in the GWB parameters that are measured by the different PTAs, agreeing within 1σ. The pulsar noise parameters are also consistent between different PTAs for the majority of the pulsars included in these analyses. We bridge the differences in modeling choices by adopting a standardized noise model for all pulsars and PTAs, finding that under this model there is a reduction in the tension in the pulsar noise parameters. As part of this reanalysis, we "extended" each PTA's data set by adding extra pulsars that were not timed by that PTA. Under these extensions, we find better constraints on the GWB amplitude and a higher signal-to-noise ratio for the Hellings–Downs correlations. These extensions serve as a prelude to the benefits offered by a full combination of data across all pulsars in the IPTA, i.e., the IPTA's Data Release 3, which will involve not just adding in additional pulsars but also including data from all three PTAs where any given pulsar is timed by more than a single PTA

    Comparing recent PTA results on the nanohertz stochastic gravitational wave background

    Full text link
    The Australian, Chinese, European, Indian, and North American pulsar timing array (PTA) collaborations recently reported, at varying levels, evidence for the presence of a nanohertz gravitational wave background (GWB). Given that each PTA made different choices in modeling their data, we perform a comparison of the GWB and individual pulsar noise parameters across the results reported from the PTAs that constitute the International Pulsar Timing Array (IPTA). We show that despite making different modeling choices, there is no significant difference in the GWB parameters that are measured by the different PTAs, agreeing within 1σ1\sigma. The pulsar noise parameters are also consistent between different PTAs for the majority of the pulsars included in these analyses. We bridge the differences in modeling choices by adopting a standardized noise model for all pulsars and PTAs, finding that under this model there is a reduction in the tension in the pulsar noise parameters. As part of this reanalysis, we "extended" each PTA's data set by adding extra pulsars that were not timed by that PTA. Under these extensions, we find better constraints on the GWB amplitude and a higher signal-to-noise ratio for the Hellings and Downs correlations. These extensions serve as a prelude to the benefits offered by a full combination of data across all pulsars in the IPTA, i.e., the IPTA's Data Release 3, which will involve not just adding in additional pulsars, but also including data from all three PTAs where any given pulsar is timed by more than as single PTA.Comment: 21 pages, 9 figures, submitted to Ap

    Effects of hospital facilities on patient outcomes after cancer surgery: an international, prospective, observational study

    Get PDF
    Background Early death after cancer surgery is higher in low-income and middle-income countries (LMICs) compared with in high-income countries, yet the impact of facility characteristics on early postoperative outcomes is unknown. The aim of this study was to examine the association between hospital infrastructure, resource availability, and processes on early outcomes after cancer surgery worldwide.Methods A multimethods analysis was performed as part of the GlobalSurg 3 study-a multicentre, international, prospective cohort study of patients who had surgery for breast, colorectal, or gastric cancer. The primary outcomes were 30-day mortality and 30-day major complication rates. Potentially beneficial hospital facilities were identified by variable selection to select those associated with 30-day mortality. Adjusted outcomes were determined using generalised estimating equations to account for patient characteristics and country-income group, with population stratification by hospital.Findings Between April 1, 2018, and April 23, 2019, facility-level data were collected for 9685 patients across 238 hospitals in 66 countries (91 hospitals in 20 high-income countries; 57 hospitals in 19 upper-middle-income countries; and 90 hospitals in 27 low-income to lower-middle-income countries). The availability of five hospital facilities was inversely associated with mortality: ultrasound, CT scanner, critical care unit, opioid analgesia, and oncologist. After adjustment for case-mix and country income group, hospitals with three or fewer of these facilities (62 hospitals, 1294 patients) had higher mortality compared with those with four or five (adjusted odds ratio [OR] 3.85 [95% CI 2.58-5.75]; p<0.0001), with excess mortality predominantly explained by a limited capacity to rescue following the development of major complications (63.0% vs 82.7%; OR 0.35 [0.23-0.53]; p<0.0001). Across LMICs, improvements in hospital facilities would prevent one to three deaths for every 100 patients undergoing surgery for cancer.Interpretation Hospitals with higher levels of infrastructure and resources have better outcomes after cancer surgery, independent of country income. Without urgent strengthening of hospital infrastructure and resources, the reductions in cancer-associated mortality associated with improved access will not be realised

    Finishing the euchromatic sequence of the human genome

    Get PDF
    The sequence of the human genome encodes the genetic instructions for human physiology, as well as rich information about human evolution. In 2001, the International Human Genome Sequencing Consortium reported a draft sequence of the euchromatic portion of the human genome. Since then, the international collaboration has worked to convert this draft into a genome sequence with high accuracy and nearly complete coverage. Here, we report the result of this finishing process. The current genome sequence (Build 35) contains 2.85 billion nucleotides interrupted by only 341 gaps. It covers ∼99% of the euchromatic genome and is accurate to an error rate of ∼1 event per 100,000 bases. Many of the remaining euchromatic gaps are associated with segmental duplications and will require focused work with new methods. The near-complete sequence, the first for a vertebrate, greatly improves the precision of biological analyses of the human genome including studies of gene number, birth and death. Notably, the human enome seems to encode only 20,000-25,000 protein-coding genes. The genome sequence reported here should serve as a firm foundation for biomedical research in the decades ahead
    corecore