52 research outputs found

    Compressive properties of commercially available polyurethane foams as mechanical models for osteoporotic human cancellous bone

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Polyurethane (PU) foam is widely used as a model for cancellous bone. The higher density foams are used as standard biomechanical test materials, but none of the low density PU foams are universally accepted as models for osteoporotic (OP) bone. The aim of this study was to determine whether low density PU foam might be suitable for mimicking human OP cancellous bone.</p> <p>Methods</p> <p>Quasi-static compression tests were performed on PU foam cylinders of different lengths (3.9 and 7.7 mm) and of different densities (0.09, 0.16 and 0.32 g.cm<sup>-3</sup>), to determine the Young's modulus, yield strength and energy absorbed to yield.</p> <p>Results</p> <p>Young's modulus values were 0.08–0.93 MPa for the 0.09 g.cm<sup>-3 </sup>foam and from 15.1–151.4 MPa for the 0.16 and 0.32 g.cm<sup>-3 </sup>foam. Yield strength values were 0.01–0.07 MPa for the 0.09 g.cm<sup>-3 </sup>foam and from 0.9–4.5 MPa for the 0.16 and 0.32 g.cm<sup>-3 </sup>foam. The energy absorbed to yield was found to be negligible for all foam cylinders.</p> <p>Conclusion</p> <p>Based on these results, it is concluded that 0.16 g.cm<sup>-3 </sup>PU foam may prove to be suitable as an OP cancellous bone model when fracture stress, but not energy dissipation, is of concern.</p

    Subregional DXA-derived vertebral bone mineral measures are stronger predictors of failure load in specimens with lower areal bone mineral density, compared to those with higher areal bone mineral density

    Get PDF
    Measurement of areal bone mineral density (aBMD) in intravertebral subregions may increase the diagnostic sensitivity of dual-energy X-ray absorptiometry (DXA)-derived parameters for vertebral fragility. This study investigated whether DXA-derived bone parameters in vertebral subregions were better predictors of vertebral bone strength in specimens with low aBMD, compared to those with higher aBMD. Twenty-five lumbar vertebrae (15 embalmed and 10 fresh-frozen) were scanned with posteroanterior- (PA) and lateral-projection DXA, and then mechanically tested in compression to ultimate failure. Whole-vertebral aBMD and bone mineral content (BMC) were measured from the PA- and lateral-projection scans and within 6 intravertebral subregions. Multivariate regression was used to predict ultimate failure load by BMC, adjusted for vertebral size and specimen fixation status across the whole specimen set, and when subgrouped into specimens with low aBMD and high aBMD. Adjusted BMC explained a substantial proportion of variance in ultimate vertebral load, when measured over the whole vertebral area in lateral projection (adjusted R2 0.84) and across the six subregions (ROIs 2–7) (adjusted R2 range 0.58–0.78). The association between adjusted BMC, either measured subregionally or across the whole vertebral area, and vertebral failure load, was increased for the subgroup of specimens with identified ‘low aBMD’, compared to those with ‘high aBMD’, particularly in the anterior subregion where the adjusted R2 differed by 0.44. The relative contribution of BMC measured in vertebral subregions to ultimate failure load is greater among specimens with lower aBMD, compared to those with higher aBMD, particularly in the anterior subregion of the vertebral body

    Characterisation of time-dependent mechanical behaviour of trabecular bone and its constituents

    Get PDF
    Trabecular bone is a porous composite material which consists of a mineral phase (mainly hydroxyapatite), organic phase (mostly type I collagen) and water assembled into a complex, hierarchical structure. In biomechanical modelling, its mechanical response to loads is generally assumed to be instantaneous, i.e. it is treated as a time-independent material. It is, however, recognised that the response of trabecular bone to loads is time-dependent. Study of this time-dependent behaviour is important in several contexts such as: to understand energy dissipation ability of bone; to understand the age-related non-traumatic fractures; to predict implant loosening due to cyclic loading; to understand progressive vertebral deformity; and for pre-clinical evaluation of total joint replacement. To investigate time-dependent behaviour, bovine trabecular bone samples were subjected to compressive loading, creep, unloading and recovery at multiple load levels (corresponding to apparent strain of 2,000-25,000 με). The results show that: the time-dependent behaviour of trabecular bone comprises of both recoverable and irrecoverable strains; the strain response is nonlinearly related to applied load levels; and the response is associated with bone volume fraction. It was found that bone with low porosity demonstrates elastic stiffening followed by elastic softening, while elastic softening is demonstrated by porous bone at relatively low loads. Linear, nonlinear viscoelastic and nonlinear viscoelastic-viscoplastic constitutive models were developed to predict trabecular bone’s time-dependent behaviour. Nonlinear viscoelastic constitutive model was found to predict the recovery behaviour well, while nonlinear viscoelastic-viscoplastic model predicts the full creep-recovery behaviour reasonably well. Depending on the requirements all these models can be used to incorporate time-dependent behaviour in finite element models. To evaluate the contribution of the key constituents of trabecular bone and its microstructure, tests were conducted on demineralised and deproteinised samples. Reversed cyclic loading experiments (tension to compression) were conducted on demineralised trabecular bone samples. It was found that demineralised bone exhibits asymmetric mechanical response - elastic stiffening in tension and softening in compression. This tension to compression transition was found to be smooth. Tensile multiple-load-creep-unload-recovery experiments on demineralised trabecular samples show irrecoverable strain (or residual strain) even at the low stress levels. Demineralised trabecular bone samples demonstrate elastic stiffening with increasing load levels in tension, and their time-dependent behaviour is nonlinear with respect to applied loads . Nonlinear viscoelastic constitutive model was developed which can predict its recovery behaviour well. Experiments on deproteinised samples showed that their modulus and strength are reasonably well related to bone volume fraction. The study considers an application of time-dependent behaviour of trabecular bone. Time-dependent properties are assigned to trabecular bone in a bone-screw system, in which the screw is subjected to cyclic loading. It is found that separation between bone and the screw at the interface can increase with increasing number of cycles which can accentuate loosening. The relative larger deformation occurs when this system to be loaded at the higher loading frequency. The deformation at the bone-screw interface is related to trabecular bone’s bone volume fraction; screws in a more porous bone are at a higher risk of loosening

    Are CT-Based Finite Element Model Predictions of Femoral Bone Strengthening Clinically Useful?

    Get PDF
    Purpose of Review: This study reviews the available literature to compare the accuracy of areal bone mineral density derived from dual X-ray absorptiometry (DXA-aBMD) and of subject-specific finite element models derived from quantitative computed tomography (QCT-SSFE) in predicting bone strength measured experimentally on cadaver bones, as well as their clinical accuracy both in terms of discrimination and prediction. Based on this information, some basic cost-effectiveness calculations are performed to explore the use of QCT-SSFE instead of DXA-aBMD in (a) clinical studies with femoral strength as endpoint, (b) predictor of the risk of hip fracture in low bone mass patients. Recent Findings: Recent improvements involving the use of smooth-boundary meshes, better anatomical referencing for proximal-only scans, multiple side-fall directions, and refined boundary conditions increase the predictive accuracy of QCT-SSFE. Summary: If these improvements are adopted, QCT-SSFE is always preferable over DXA-aBMD in clinical studies with femoral strength as the endpoint, while it is not yet cost-effective as a hip fracture risk predictor, although pathways that combine both QCT-SSFE and DXA-aBMD are promising

    Nonlinear viscoelastic characterization of bovine trabecular bone

    Get PDF
    The time-independent elastic properties of trabecular bone have been extensively investigated, and several stiffness–density relations have been proposed. Although it is recognized that trabecular bone exhibits time-dependent mechanical behaviour, a property of viscoelastic materials, the characterization of this behaviour has received limited attention. The objective of the present study was to investigate the time-dependent behaviour of bovine trabecular bone through a series of compressive creep–recovery experiments and to identify its nonlinear constitutive viscoelastic material parameters. Uniaxial compressive creep and recovery experiments at multiple loads were performed on cylindrical bovine trabecular bone samples ([Formula: see text] ). Creep response was found to be significant and always comprised of recoverable and irrecoverable strains, even at low stress/strain levels. This response was also found to vary nonlinearly with applied stress. A systematic methodology was developed to separate recoverable (nonlinear viscoelastic) and irrecoverable (permanent) strains from the total experimental strain response. We found that Schapery’s nonlinear viscoelastic constitutive model describes the viscoelastic response of the trabecular bone, and parameters associated with this model were estimated from the multiple load creep–recovery (MLCR) experiments. Nonlinear viscoelastic recovery compliance was found to have a decreasing and then increasing trend with increasing stress level, indicating possible stiffening and softening behaviour of trabecular bone due to creep. The obtained parameters from MLCR tests, expressed as second-order polynomial functions of stress, showed a similar trend for all the samples, and also demonstrate stiffening–softening behaviour with increasing stress

    The effect of osteoporotic vertebral fracture on predicted spinal loads in vivo

    Get PDF
    The aetiology of osteoporotic vertebral fractures is multi-factorial, and cannot be explained solely by low bone mass. After sustaining an initial vertebral fracture, the risk of subsequent fracture increases greatly. Examination of physiologic loads imposed on vertebral bodies may help to explain a mechanism underlying this fracture cascade. This study tested the hypothesis that model-derived segmental vertebral loading is greater in individuals who have sustained an osteoporotic vertebral fracture compared to those with osteoporosis and no history of fracture. Flexion moments, and compression and shear loads were calculated from T2 to L5 in 12 participants with fractures (66.4 ± 6.4 years, 162.2 ± 5.1 cm, 69.1 ± 11.2 kg) and 19 without fractures (62.9 ± 7.9 years, 158.3 ± 4.4 cm, 59.3 ± 8.9 kg) while standing. Static analysis was used to solve gravitational loads while muscle-derived forces were calculated using a detailed trunk muscle model driven by optimization with a cost function set to minimise muscle fatigue. Least squares regression was used to derive polynomial functions to describe normalised load profiles. Regression co-efficients were compared between groups to examine differences in loading profiles. Loading at the fractured level, and at one level above and below, were also compared between groups. The fracture group had significantly greater normalised compression (p = 0.0008) and shear force (p < 0.0001) profiles and a trend for a greater flexion moment profile. At the level of fracture, a significantly greater flexion moment (p = 0.001) and shear force (p < 0.001) was observed in the fracture group. A greater flexion moment (p = 0.003) and compression force (p = 0.007) one level below the fracture, and a greater flexion moment (p = 0.002) and shear force (p = 0.002) one level above the fracture was observed in the fracture group. The differences observed in multi-level spinal loading between the groups may explain a mechanism for increased risk of subsequent vertebral fractures. Interventions aimed at restoring vertebral morphology or reduce thoracic curvature may assist in normalising spine load profiles. © 2006 Springer-Verlag

    Unmet needs and current and future approaches for osteoporotic patients at high risk of hip fracture

    Full text link

    The associations between QCT-based vertebral bone measurements and prevalent vertebral fractures depend on the spinal locations of both bone measurement and fracture

    No full text
    UnlabelledWe examined how spinal location affects the relationships between quantitative computed tomography (QCT)-based bone measurements and prevalent vertebral fractures. Upper spine (T4-T10) fractures appear to be more strongly related to bone measures than lower spine (T11-L4) fractures, while lower spine measurements are at least as strongly related to fractures as upper spine measurements.IntroductionVertebral fracture (VF), a common injury in older adults, is most prevalent in the mid-thoracic (T7-T8) and thoracolumbar (T12-L1) areas of the spine. However, measurements of bone mineral density (BMD) are typically made in the lumbar spine. It is not clear how the associations between bone measurements and VFs are affected by the spinal locations of both bone measurements and VF.MethodsA community-based case-control study includes 40 cases with moderate or severe prevalent VF and 80 age- and sex-matched controls. Measures of vertebral BMD, strength (estimated by finite element analysis), and factor of risk (load:strength ratio) were determined based on QCT scans at the L3 and T10 vertebrae. Associations were determined between bone measures and prevalent VF occurring at any location, in the upper spine (T4-T10), or in the lower spine (T11-L4).ResultsPrevalent VF at any location was significantly associated with bone measures, with odds ratios (ORs) generally higher for measurements made at L3 (ORs = 1.9-3.9) than at T10 (ORs = 1.5-2.4). Upper spine fracture was associated with these measures at both T10 and L3 (ORs = 1.9-8.2), while lower spine fracture was less strongly associated (ORs = 1.0-2.4) and only reached significance for volumetric BMD measures at L3.ConclusionsCloser proximity between the locations of bone measures and prevalent VF does not strengthen associations between bone measures and fracture. Furthermore, VF etiology may vary by region, with VFs in the upper spine more strongly related to skeletal fragility
    • …
    corecore