4,264 research outputs found
The ARGUS Vertex Trigger
A fast second level trigger has been developed for the ARGUS experiment which
recognizes tracks originating from the interaction region. The processor
compares the hits in the ARGUS Micro Vertex Drift Chamber to 245760 masks
stored in random access memories. The masks which are fully defined in three
dimensions are able to reject tracks originating in the wall of the narrow
beampipe of 10.5\,mm radius.Comment: gzipped Postscript, 27 page
Penghilangan Mikroorganisme Dalam Air Minum Dengan Dielectric Barrier Discharge
Microorganisms such as Escherichia coli in water are a component that is difficult to remove in conventional water treatment systems. Several systems have been implemented to reduce levels of microorganisms is the use of disinfectants, the membrane filtration and activated carbon absorption. These systems have several weaknesses, so that not all microorganisms can be removed from drinking water. The plasma system is an applicable technology for removing organic compounds and microorganisms in drinking water. By creating plasma in water will produce several of active species such as OH-, H+, O3 and H2O2 that has a high oxidation potential, decompose organic compounds and kill microorganisms in the water significantly. This paper will describe the removal of microorganisms in drinking water using a plasma system by the method of dielectric barrier discharge (DBD ). The results howed that the pH of drinking water produced in the range 6.5 to 7.3. The higher voltage causes the higher the conductivity, temperature and ORP water. Removal efficiency for the content of microorganisms Coli Fecal and Coliform in the range 99.2 to 100% after water was injected voltage of 13-17 kV for 10 minutes
Determination of the Michel Parameters rho, xi, and delta in tau-Lepton Decays with tau --> rho nu Tags
Using the ARGUS detector at the storage ring DORIS II, we have
measured the Michel parameters , , and for
decays in -pair events produced at
center of mass energies in the region of the resonances. Using
as spin analyzing tags, we find , , , , and . In addition, we report
the combined ARGUS results on , , and using this work
und previous measurements.Comment: 10 pages, well formatted postscript can be found at
http://pktw06.phy.tu-dresden.de/iktp/pub/desy97-194.p
Application of Al-Cu-W-Ta graded density impactors in dynamic ramp compression experiments
Graded density impactors (GDIs) are used to dynamically compress materials to extreme conditions. Two modifications to a previously developed Mg-Cu-W GDI are made in this work before using it in a dynamic compression experiment: Mg is replaced with Al and a Ta disk is glued to the back. The Mg phase is replaced by Al because FCC Al remains solid to higher pressure along its Hugoniot compared to Mg. The addition of the Ta disk creates a constant particle velocity regime and facilitates a definition of peak pressure states. Microstructure analysis, profilometry, and ultrasonic C-scans of the Al-Cu-W GDI all confirm excellent uniformity. We evaluated signal variation in the radial direction of a dynamically compressed Al-LiF bilayer target to evaluate the contribution of spatial nonuniformity to errors. Velocity traces from five photon Doppler velocimetry (PDV) probes located at different radial distances from the center of the target varied at most by 1.1% with a root mean square of 0.3% during the compression ramp, demonstrating low PDV measurement error over a relatively large experimental area. The experimental PDV data also agrees well with 1D simulations that use inputs from predictive characterization models developed for the material properties resulting from tape casting, laminating, and powder consolidation processes. Low measurement error during quasi-isentropic compression, leading to better precision, ensures a robust platform to reach extreme compression and low-temperature recovery states and facilitates discovery via synthesis, quenching, and preservation of new high-pressure phases
Application of Al-Cu-W-Ta graded density impactors in dynamic ramp compression experiments
Graded density impactors (GDIs) are used to dynamically compress materials to extreme conditions. Two modifications to a previously developed Mg-Cu-W GDI are made in this work before using it in a dynamic compression experiment: Mg is replaced with Al and a Ta disk is glued to the back. The Mg phase is replaced by Al because FCC Al remains solid to higher pressure along its Hugoniot compared to Mg. The addition of the Ta disk creates a constant particle velocity regime and facilitates a definition of peak pressure states. Microstructure analysis, profilometry, and ultrasonic C-scans of the Al-Cu-W GDI all confirm excellent uniformity. We evaluated signal variation in the radial direction of a dynamically compressed Al-LiF bilayer target to evaluate the contribution of spatial nonuniformity to errors. Velocity traces from five photon Doppler velocimetry (PDV) probes located at different radial distances from the center of the target varied at most by 1.1% with a root mean square of 0.3% during the compression ramp, demonstrating low PDV measurement error over a relatively large experimental area. The experimental PDV data also agrees well with 1D simulations that use inputs from predictive characterization models developed for the material properties resulting from tape casting, laminating, and powder consolidation processes. Low measurement error during quasi-isentropic compression, leading to better precision, ensures a robust platform to reach extreme compression and low-temperature recovery states and facilitates discovery via synthesis, quenching, and preservation of new high-pressure phases
Measurement of Branching Fractions and Rate Asymmetries in the Rare Decays B -> K(*) l+ l-
In a sample of 471 million BB events collected with the BABAR detector at the
PEP-II e+e- collider we study the rare decays B -> K(*) l+ l-, where l+ l- is
either e+e- or mu+mu-. We report results on partial branching fractions and
isospin asymmetries in seven bins of di-lepton mass-squared. We further present
CP and lepton-flavor asymmetries for di-lepton masses below and above the J/psi
resonance. We find no evidence for CP or lepton-flavor violation. The partial
branching fractions and isospin asymmetries are consistent with the Standard
Model predictions and with results from other experiments.Comment: 16 pages, 14 figures, accepted by Phys. Rev.
Improved Limits on decays to invisible final states
We establish improved upper limits on branching fractions for B0 decays to
final States 10 where the decay products are purely invisible (i.e., no
observable final state particles) and for final states where the only visible
product is a photon. Within the Standard Model, these decays have branching
fractions that are below the current experimental sensitivity, but various
models of physics beyond the Standard Model predict significant contributions
for these channels. Using 471 million BB pairs collected at the Y(4S) resonance
by the BABAR experiment at the PEP-II e+e- storage ring at the SLAC National
Accelerator Laboratory, we establish upper limits at the 90% confidence level
of 2.4x10^-5 for the branching fraction of B0-->Invisible and 1.7x10^-5 for the
branching fraction of B0-->Invisible+gammaComment: 8 pages, 3 postscript figures, submitted to Phys. Rev. D (Rapid
Communications
Recommended from our members
Measurement of B(B-->X_s {\gamma}), the B-->X_s {\gamma} photon energy spectrum, and the direct CP asymmetry in B-->X_{s+d} {\gamma} decays
The photon spectrum in B --> X_s {\gamma} decay, where X_s is any strange
hadronic state, is studied using a data sample of (382.8\pm 4.2) \times 10^6
e^+ e^- --> \Upsilon(4S) --> BBbar events collected by the BABAR experiment at
the PEP-II collider. The spectrum is used to measure the branching fraction B(B
--> X_s \gamma) = (3.21 \pm 0.15 \pm 0.29 \pm 0.08)\times 10^{-4} and the
first, second, and third moments = 2.267 \pm 0.019 \pm 0.032 \pm
0.003 GeV,, )^2> = 0.0484 \pm 0.0053 \pm 0.0077 \pm
0.0005 GeV^2, and )^3> = -0.0048 \pm 0.0011 \pm 0.0011
\pm 0.0004 GeV^3, for the range E_\gamma > 1.8 GeV, where E_{\gamma} is the
photon energy in the B-meson rest frame. Results are also presented for
narrower E_{\gamma} ranges. In addition, the direct CP asymmetry A_{CP}(B -->
X_{s+d} \gamma) is measured to be 0.057 \pm 0.063. The spectrum itself is also
unfolded to the B-meson rest frame; that is the frame in which theoretical
predictions for its shape are made.Comment: 37 pages, 19 postscript figures, submitted to Phys. Rev. D. No
analysis or results have changed from previous version. Some changes to
improve clarity based on interactions with Phys. Rev. D referees, including
one new Figure (Fig. 13), and some minor wording/punctuation/spelling
mistakes fixe
Search for lepton-number violating processes in B+ -> h- l+ l+ decays
We have searched for the lepton-number violating processes B+ -> h- l+ l+
with h- = K-/pi- and l+ = e+/mu+, using a sample of 471+/-3 million BBbar
events collected with the BaBar detector at the PEP-II e+e- collider at the
SLAC National Accelerator Laboratory. We find no evidence for these decays and
place 90% confidence level upper limits on their branching fractions Br(B+ ->
pi- e+ e+) K- e+ e+) pi-
mu+ mu+) K- mu+ mu+) < 6.7 x 10^{-8}.Comment: 8 pages, 4 postscript figures, submitted to Phys. Rev. D. R
Recommended from our members
Precise Measurement of the e+ e- --> pi+ pi- (gamma) Cross Section with the Initial-State Radiation Method at BABAR
A precise measurement of the cross section of the process
from threshold to an energy of 3GeV is obtained
with the initial-state radiation (ISR) method using 232fb of data
collected with the BaBar detector at center-of-mass energies near
10.6GeV. The ISR luminosity is determined from a study of the leptonic process
, which is found to agree with the
next-to-leading-order QED prediction to within 1.1%. The cross section for the
process is obtained with a systematic uncertainty
of 0.5% in the dominant resonance region. The leading-order hadronic
contribution to the muon magnetic anomaly calculated using the measured
cross section from threshold to 1.8GeV is .Comment: 58 pages, 56 figures, to be submitted to Phys. Rev.
- …