191 research outputs found

    Laserlight visual cueing device for freezing of gait in Parkinson's disease: a case study of the biomechanics involved

    Get PDF
    AbstractBackground: Freezing of gait (FOG) is a serious gait disorder affecting up to two-thirds of people with Parkinson's disease (PD). Cueing has been explored as a method of generating motor execution using visual transverse lines on the floor. However, the impact of a laser light visual cue remains unclear. Objective: To determine the biomechanical effect of a laser cane on FOG in a participant with PD compared to a healthy age- and gender-matched control. Methods: The participant with PD and healthy control were given a task of initiating gait from standing. Electromyography (EMG) data were collected from the tibialis anterior (TA) and the medial gastrocnemius (GS) muscles using an 8-channel system. A 10-camera system (Qualisys) recorded movement in 6 degrees of freedom and a calibrated anatomical system technique was used to construct a full body model. Center of mass (COM) and center of pressure (COP) were the main outcome measures. Results: The uncued condition showed that separation of COM and COP took longer and was of smaller magnitude than the cued condition. EMG activity revealed prolonged activation of GS, with little to no TA activity. The cued condition showed earlier COM and COP separation. There was reduced fluctuation in GS, with abnormal, early bursts of TA activity. Step length improved in the cued condition compared to the uncued condition. Conclusion: Laserlight visual cueing improved step length beyond a non-cued condition for this patient indicating improved posture and muscle control

    Managing the supercell approximation for charged defects in semiconductors: finite size scaling, charge correction factors, the bandgap problem and the ab initio dielectric constant

    Get PDF
    The errors arising in ab initio density functional theory studies of semiconductor point defects using the supercell approximation are analyzed. It is demonstrated that a) the leading finite size errors are inverse linear and inverse cubic in the supercell size, and b) finite size scaling over a series of supercells gives reliable isolated charged defect formation energies to around +-0.05 eV. The scaled results are used to test three correction methods. The Makov-Payne method is insufficient, but combined with the scaling parameters yields an ab initio dielectric constant of 11.6+-4.1 for InP. Gamma point corrections for defect level dispersion are completely incorrect, even for shallow levels, but re-aligning the total potential in real-space between defect and bulk cells actually corrects the electrostatic defect-defect interaction errors as well. Isolated defect energies to +-0.1 eV are then obtained using a 64 atom supercell, though this does not improve for larger cells. Finally, finite size scaling of known dopant levels shows how to treat the band gap problem: in less than about 200 atom supercells with no corrections, continuing to consider levels into the theoretical conduction band (extended gap) comes closest to experiment. However, for larger cells or when supercell approximation errors are removed, a scissors scheme stretching the theoretical band gap onto the experimental one is in fact correct.Comment: 11 pages, 3 figures (6 figure files). Accepted for Phys Rev

    Defects in SiO2 as the possible origin of near interface traps in the SiC∕SiO2 system: A systematic theoretical study

    Get PDF
    A systematic study of the level positions of intrinsic and carbon defects in SiO2 is presented, based on density functional calculations with a hybrid functional in an alpha-quartz supercell. The results are analyzed from the point of view of the near interface traps (NIT), observed in both SiC/SiO2 and Si/SiO2 systems, and assumed to have their origins in the oxide. It is shown that the vacancies and the oxygen interstitial can be excluded as the origin of such NIT, while the silicon interstitial and carbon dimers give rise to gap levels in the energy range inferred from experiments. The properties of these defects are discussed in light of the knowledge about the SiC/SiO2 interface

    Quadrupole Susceptibility and Elastic Softening due to a Vacancy in Silicon Crystal

    Full text link
    We investigate the electronic states around a single vacancy in silicon crystal by using the Green's function approach. The triply degenerate vacancy states within the band gap are found to be extended over a large distance 20A˚\sim20 {\rm \AA} from the vacancy site and contribute to the reciprocal temperature dependence of the quadrupole susceptibility resulting in the elastic softening at low temperture. The Curie constant of the quadrupole susceptibility for the trigonal mode (Oyz,Ozx,OxyO_{yz},O_{zx},O_{xy}) is largely enhanced as compared to that for the tetragonal mode (O20,O22O_{2}^{0},O_{2}^{2}). The obtained results are consistent with the recent ultrasonic experiments in silicon crystal down to 20 mK. We also calculate the dipole and octupole susceptibilities and find that the octupole susceptibilities are extremely enhannced for a specific mode.Comment: 6 pages, with 5 figure

    Quantum ESPRESSO: a modular and open-source software project for quantum simulations of materials

    Get PDF
    Quantum ESPRESSO is an integrated suite of computer codes for electronic-structure calculations and materials modeling, based on density-functional theory, plane waves, and pseudopotentials (norm-conserving, ultrasoft, and projector-augmented wave). Quantum ESPRESSO stands for "opEn Source Package for Research in Electronic Structure, Simulation, and Optimization". It is freely available to researchers around the world under the terms of the GNU General Public License. Quantum ESPRESSO builds upon newly-restructured electronic-structure codes that have been developed and tested by some of the original authors of novel electronic-structure algorithms and applied in the last twenty years by some of the leading materials modeling groups worldwide. Innovation and efficiency are still its main focus, with special attention paid to massively-parallel architectures, and a great effort being devoted to user friendliness. Quantum ESPRESSO is evolving towards a distribution of independent and inter-operable codes in the spirit of an open-source project, where researchers active in the field of electronic-structure calculations are encouraged to participate in the project by contributing their own codes or by implementing their own ideas into existing codes.Comment: 36 pages, 5 figures, resubmitted to J.Phys.: Condens. Matte

    Internal dose assessment of 210Po using biokinetic modeling and urinary excretion measurement

    Get PDF
    The mysterious death of Mr. Alexander Litvinenko who was most possibly poisoned by Polonium-210 (210Po) in November 2006 in London attracted the attention of the public to the kinetics, dosimetry and the risk of this high radiotoxic isotope in the human body. In the present paper, the urinary excretion of seven persons who were possibly exposed to traces of 210Po was monitored. The values measured in the GSF Radioanalytical Laboratory are in the range of natural background concentration. To assess the effective dose received by those persons, the time-dependence of the organ equivalent dose and the effective dose after acute ingestion and inhalation of 210Po were calculated using the biokinetic model for polonium (Po) recommended by the International Commission on Radiological Protection (ICRP) and the one recently published by Leggett and Eckerman (L&E). The daily urinary excretion to effective dose conversion factors for ingestion and inhalation were evaluated based on the ICRP and L&E models for members of the public. The ingestion (inhalation) effective dose per unit intake integrated over one day is 1.7 × 10−8 (1.4 × 10−7) Sv Bq−1, 2.0 × 10−7 (9.6 × 10−7) Sv Bq−1 over 10 days, 5.2 × 10−7 (2.0 × 10−6) Sv Bq−1 over 30 days and 1.0 × 10−6 (3.0 × 10−6) Sv Bq−1 over 100 days. The daily urinary excretions after acute ingestion (inhalation) of 1 Bq of 210Po are 1.1 × 10−3 (1.0 × 10−4) on day 1, 2.0 × 10−3 (1.9 × 10−4) on day 10, 1.3 × 10−3 (1.7 × 10−4) on day 30 and 3.6 × 10−4 (8.3 × 10−5) Bq d−1 on day 100, respectively. The resulting committed effective doses range from 2.1 × 10−3 to 1.7 × 10−2 mSv by an assumption of ingestion and from 5.5 × 10−2 to 4.5 × 10−1 mSv by inhalation. For the case of Mr. Litvinenko, the mean organ absorbed dose as a function of time was calculated using both the above stated models. The red bone marrow, the kidneys and the liver were considered as the critical organs. Assuming a value of lethal absorbed dose of 5 Gy to the bone marrow, 6 Gy to the kidneys and 8 Gy to the liver, the amount of 210Po which Mr. Litvinenko might have ingested is therefore estimated to range from 27 to 1,408 MBq, i.e 0.2–8.5 μg, depending on the modality of intake and on different assumptions about blood absorption

    EPR, ESE and pulsed ENDOR study of nitrogen related centers in 4H-SiC wafers grown by different technologies

    Get PDF
    D-band electron paramagnetic resonance (EPR) measurements as well as X and Q-band field-swept Electron Spin Echo (ESE) and pulsed Electron Nuclear Double Resonance (ENDOR) studies were performed on a series of n-type 4H-SiC wafers grown by different techniques including sublimation sandwich method (SSM), physical vapor transport (PVT) and modified Lely method. Depending on the C/Si ratio and the growth temperature the n-type 4H-SiC wafers revealed, besides a triplet due to nitrogen residing on the cubic site (Nc), two nitrogen (N) related EPR spectra with g||=2.0055, g⊥=2.0010 and g||=2.0063, g⊥=2.0005 with different intensities. In the samples with low C/Si ratio the EPR spectrum with g||=2.0055, g⊥=2.0010 consists of a triplet with low intensity which is tentatively explained as a N-related complex, while in the samples with high C/Si ratio the triplet is transformed into one structureless line of high intensity, which is explained as being due to an exchange interaction between N donors. In the samples grown at low temperature with enhanced carbon concentration the EPR line with g||=2.0063, g⊥=2.0005 and a small hyperfine (hf) interaction dominates the EPR spectrum. It is attributed to N on the hexagonal lattice site. The interpretation of the EPR data is supported by activation energies and donor concentrations obtained from Hall effect measurements for three donor levels in this series of 4H-SiC samples

    Elective high-frequency oscillatory ventilation in preterm infants with respiratory distress syndrome: an individual patient data meta-analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Despite the considerable amount of evidence from randomized controlled trials and meta-analyses, uncertainty remains regarding the efficacy and safety of high-frequency oscillatory ventilation as compared to conventional ventilation in the early treatment of respiratory distress syndrome in preterm infants. This results in a wide variation in the clinical use of high-frequency oscillatory ventilation for this indication throughout the world. The reasons are an unexplained heterogeneity between trial results and a number of unanswered, clinically important questions. Do infants with different risk profiles respond differently to high-frequency oscillatory ventilation? How does the ventilation strategy affect outcomes? Does the delay – either from birth or from the moment of intubation – to the start of high-frequency oscillation modify the effect of the intervention? Instead of doing new trials, those questions can be addressed by re-analyzing the individual patient data from the existing randomized controlled trials.</p> <p>Methods/Design</p> <p>A systematic review with meta-analysis based on individual patient data. This involves the central collection, validation and re-analysis of the original individual data from each infant included in each randomized controlled trial addressing this question.</p> <p>The study objective is to estimate the effect of high-frequency oscillatory ventilation on the risk for the combined outcome of death or bronchopulmonary dysplasia or a severe adverse neurological event. In addition, it will explore whether the effect of high-frequency oscillatory ventilation differs by the infant's risk profile, defined by gestational age, intrauterine growth restriction, severity of lung disease at birth and whether or not corticosteroids were given to the mother prior to delivery. Finally, it will explore the importance of effect modifying factors such as the ventilator device, ventilation strategy and the delay to the start of high-frequency ventilation.</p> <p>Discussion</p> <p>An international collaborative group, the PreVILIG Collaboration (Prevention of Ventilator Induced Lung Injury Group), has been formed with the investigators of the original randomized trials to conduct this systematic review. In the field of neonatology, individual patient data meta-analysis has not been used previously. Final results are expected to be available by the end of 2009.</p
    corecore