12,317 research outputs found

    Application of large area SiPMs for the readout of a plastic scintillator based timing detector

    Full text link
    In this study an array of eight 6 mm x 6 mm area SiPMs was coupled to the end of a long plastic scintillator counter which was exposed to a 2.5 GeV/c muon beam at the CERN PS. Timing characteristics of bars with dimensions 150 cm x 6 cm x 1 cm and 120 cm x 11 cm x 2.5 cm have been studied. An 8-channel SiPM anode readout ASIC (MUSIC R1) based on a novel low input impedance current conveyor has been used to read out and amplify SiPMs independently and sum the signals at the end. Prospects for applications in large-scale particle physics detectors with timing resolution below 100 ps are provided in light of the results

    Application of large area SiPMs for the readout of a plastic scintillator based timing detector

    Full text link
    In this study an array of eight 6 mm x 6 mm area SiPMs was coupled to the end of a long plastic scintillator counter which was exposed to a 2.5 GeV/c muon beam at the CERN PS. Timing characteristics of bars with dimensions 150 cm x 6 cm x 1 cm and 120 cm x 11 cm x 2.5 cm have been studied. An 8-channel SiPM anode readout ASIC (MUSIC R1) based on a novel low input impedance current conveyor has been used to read out and amplify SiPMs independently and sum the signals at the end. Prospects for applications in large-scale particle physics detectors with timing resolution below 100 ps are provided in light of the results

    Higgs boson production via vector-like top-partner decays: diphoton or multilepton plus multijets channels at the LHC

    Get PDF
    We first build a minimal model of vector-like quarks where the dominant Higgs boson production process at LHC -- the gluon fusion -- can be significantly suppressed, being motivated by the recent stringent constraints from the search for direct Higgs production over a wide Higgs mass range. Within this model, compatible with the present experimental constraints on direct Higgs searches, we demonstrate that the Higgs (hh) production via a heavy vector-like top-partner (t2t_2) decay, ppt2tˉ2pp \to t_2 \bar t_2, t2tht_2\to t h, allows to discover a Higgs boson at the LHC and measure its mass, through the decay channels hγγh\to \gamma\gamma or hZZh\to ZZ. We also comment on the recent hint in LHC data from a possible 125\sim 125 GeV Higgs scalar, in the presence of heavy vector-like top quarks.Comment: 14 pages, 8 figure

    Effects of Residue Background Events in Direct Dark Matter Detection Experiments on the Determination of the WIMP Mass

    Full text link
    In the earlier work on the development of a model-independent data analysis method for determining the mass of Weakly Interacting Massive Particles (WIMPs) by using measured recoil energies from direct Dark Matter detection experiments directly, it was assumed that the analyzed data sets are background-free, i.e., all events are WIMP signals. In this article, as a more realistic study, we take into account a fraction of possible residue background events, which pass all discrimination criteria and then mix with other real WIMP-induced events in our data sets. Our simulations show that, for the determination of the WIMP mass, the maximal acceptable fraction of residue background events in the analyzed data sets of O(50) total events is ~20%, for background windows of the entire experimental possible energy ranges, or in low energy ranges; while, for background windows in relatively higher energy ranges, this maximal acceptable fraction of residue background events can not be larger than ~10%. For a WIMP mass of 100 GeV with 20% background events in the windows of the entire experimental possible energy ranges, the reconstructed WIMP mass and the 1-sigma statistical uncertainty are ~97 GeV^{+61%}_{-35%} (~94 GeV^{+55%}_{-33%} for background-free data sets).Comment: 27 pages, 22 eps figures; v2: revised version for publication, references added and update

    A Case of Urogenital Human Schistosomiasis from a Non-endemic Area

    Get PDF
    © 2015 Calvo-Cano et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. The attached file is the published version of the article

    Measurement of Trace I-129 Concentrations in CsI Powder and Organic Liquid Scintillator with Accelerator Mass Spectrometry

    Full text link
    Levels of trace radiopurity in active detector materials is a subject of major concern in low-background experiments. Procedures were devised to measure trace concentrations of I-129 in the inorganic salt CsI as well as in organic liquid scintillator with Accelerator Mass Spectrometry (AMS) which leads to improvement in sensitivities by several orders of magnitude over other methods. No evidence of their existence in these materials were observed. Limits of < 6 X 10^{-13} g/g and < 2.6 X 10^{-17} g/g on the contaminations of I-129 in CsI and liquid scintillator, respectively, were derived.These are the first results in a research program whose goals are to develop techniques to measure trace radioactivity in detector materials by AMS.Comment: Proceedings of 10th International Conference on Accelerator Mass Spectrometr

    Background discrimination capabilities of a heat and ionization germanium cryogenic detector

    Get PDF
    The discrimination capabilities of a 70 g heat and ionization Ge bolometer are studied. This first prototype has been used by the EDELWEISS Dark Matter experiment, installed in the Laboratoire Souterrain de Modane, for direct detection of WIMPs. Gamma and neutron calibrations demonstrate that this type of detector is able to reject more than 99.6% of the background while retaining 95% of the signal, provided that the background events distribution is not biased towards the surface of the Ge crystal. However, the 1.17 kg.day of data taken in a relatively important radioactive environment show an extra population slightly overlapping the signal. This background is likely due to interactions of low energy photons or electrons near the surface of the crystal, and is somewhat reduced by applying a higher charge-collecting inverse bias voltage (-6 V instead of -2 V) to the Ge diode. Despite this contamination, more than 98% of the background can be rejected while retaining 50% of the signal. This yields a conservative upper limit of 0.7 event.day^{-1}.kg^{-1}.keV^{-1}_{recoil} at 90% confidence level in the 15-45 keV recoil energy interval; the present sensitivity appears to be limited by the fast ambient neutrons. Upgrades in progress on the installation are summarized.Comment: Submitted to Astroparticle Physics, 14 page

    Les Houches "Physics at TeV Colliders 2003" Beyond the Standard Model Working Group: Summary Report

    Full text link
    The work contained herein constitutes a report of the ``Beyond the Standard Model'' working group for the Workshop "Physics at TeV Colliders", Les Houches, France, 26 May--6 June, 2003. The research presented is original, and was performed specifically for the workshop. Tools for calculations in the minimal supersymmetric standard model are presented, including a comparison of the dark matter relic density predicted by public codes. Reconstruction of supersymmetric particle masses at the LHC and a future linear collider facility is examined. Less orthodox supersymmetric signals such as non-pointing photons and R-parity violating signals are studied. Features of extra dimensional models are examined next, including measurement strategies for radions and Higgs', as well as the virtual effects of Kaluza Klein modes of gluons. An LHC search strategy for a heavy top found in many little Higgs model is presented and finally, there is an update on LHC ZZ' studies.Comment: 113 pages, ed B.C. Allanach, v5 has changes to part XV

    The EDELWEISS Experiment : Status and Outlook

    Get PDF
    The EDELWEISS Dark Matter search uses low-temperature Ge detectors with heat and ionisation read- out to identify nuclear recoils induced by elastic collisions with WIMPs from the galactic halo. Results from the operation of 70 g and 320 g Ge detectors in the low-background environment of the Modane Underground Laboratory (LSM) are presented.Comment: International Conference on Dark Matter in Astro and Particle Physics (Dark 2000), Heidelberg, Germany, 10-16 Jul 2000, v3 minor revision
    corecore