12,317 research outputs found
Application of large area SiPMs for the readout of a plastic scintillator based timing detector
In this study an array of eight 6 mm x 6 mm area SiPMs was coupled to the end
of a long plastic scintillator counter which was exposed to a 2.5 GeV/c muon
beam at the CERN PS. Timing characteristics of bars with dimensions 150 cm x 6
cm x 1 cm and 120 cm x 11 cm x 2.5 cm have been studied. An 8-channel SiPM
anode readout ASIC (MUSIC R1) based on a novel low input impedance current
conveyor has been used to read out and amplify SiPMs independently and sum the
signals at the end. Prospects for applications in large-scale particle physics
detectors with timing resolution below 100 ps are provided in light of the
results
Application of large area SiPMs for the readout of a plastic scintillator based timing detector
In this study an array of eight 6 mm x 6 mm area SiPMs was coupled to the end
of a long plastic scintillator counter which was exposed to a 2.5 GeV/c muon
beam at the CERN PS. Timing characteristics of bars with dimensions 150 cm x 6
cm x 1 cm and 120 cm x 11 cm x 2.5 cm have been studied. An 8-channel SiPM
anode readout ASIC (MUSIC R1) based on a novel low input impedance current
conveyor has been used to read out and amplify SiPMs independently and sum the
signals at the end. Prospects for applications in large-scale particle physics
detectors with timing resolution below 100 ps are provided in light of the
results
Higgs boson production via vector-like top-partner decays: diphoton or multilepton plus multijets channels at the LHC
We first build a minimal model of vector-like quarks where the dominant Higgs
boson production process at LHC -- the gluon fusion -- can be significantly
suppressed, being motivated by the recent stringent constraints from the search
for direct Higgs production over a wide Higgs mass range. Within this model,
compatible with the present experimental constraints on direct Higgs searches,
we demonstrate that the Higgs () production via a heavy vector-like
top-partner () decay, , , allows to
discover a Higgs boson at the LHC and measure its mass, through the decay
channels or . We also comment on the recent hint
in LHC data from a possible GeV Higgs scalar, in the presence of
heavy vector-like top quarks.Comment: 14 pages, 8 figure
Effects of Residue Background Events in Direct Dark Matter Detection Experiments on the Determination of the WIMP Mass
In the earlier work on the development of a model-independent data analysis
method for determining the mass of Weakly Interacting Massive Particles (WIMPs)
by using measured recoil energies from direct Dark Matter detection experiments
directly, it was assumed that the analyzed data sets are background-free, i.e.,
all events are WIMP signals. In this article, as a more realistic study, we
take into account a fraction of possible residue background events, which pass
all discrimination criteria and then mix with other real WIMP-induced events in
our data sets. Our simulations show that, for the determination of the WIMP
mass, the maximal acceptable fraction of residue background events in the
analyzed data sets of O(50) total events is ~20%, for background windows of the
entire experimental possible energy ranges, or in low energy ranges; while, for
background windows in relatively higher energy ranges, this maximal acceptable
fraction of residue background events can not be larger than ~10%. For a WIMP
mass of 100 GeV with 20% background events in the windows of the entire
experimental possible energy ranges, the reconstructed WIMP mass and the
1-sigma statistical uncertainty are ~97 GeV^{+61%}_{-35%} (~94
GeV^{+55%}_{-33%} for background-free data sets).Comment: 27 pages, 22 eps figures; v2: revised version for publication,
references added and update
A Case of Urogenital Human Schistosomiasis from a Non-endemic Area
© 2015 Calvo-Cano et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. The attached file is the published version of the article
Measurement of Trace I-129 Concentrations in CsI Powder and Organic Liquid Scintillator with Accelerator Mass Spectrometry
Levels of trace radiopurity in active detector materials is a subject of
major concern in low-background experiments. Procedures were devised to measure
trace concentrations of I-129 in the inorganic salt CsI as well as in organic
liquid scintillator with Accelerator Mass Spectrometry (AMS) which leads to
improvement in sensitivities by several orders of magnitude over other methods.
No evidence of their existence in these materials were observed. Limits of < 6
X 10^{-13} g/g and < 2.6 X 10^{-17} g/g on the contaminations of I-129 in CsI
and liquid scintillator, respectively, were derived.These are the first results
in a research program whose goals are to develop techniques to measure trace
radioactivity in detector materials by AMS.Comment: Proceedings of 10th International Conference on Accelerator Mass
Spectrometr
Background discrimination capabilities of a heat and ionization germanium cryogenic detector
The discrimination capabilities of a 70 g heat and ionization Ge bolometer
are studied. This first prototype has been used by the EDELWEISS Dark Matter
experiment, installed in the Laboratoire Souterrain de Modane, for direct
detection of WIMPs. Gamma and neutron calibrations demonstrate that this type
of detector is able to reject more than 99.6% of the background while retaining
95% of the signal, provided that the background events distribution is not
biased towards the surface of the Ge crystal. However, the 1.17 kg.day of data
taken in a relatively important radioactive environment show an extra
population slightly overlapping the signal. This background is likely due to
interactions of low energy photons or electrons near the surface of the
crystal, and is somewhat reduced by applying a higher charge-collecting inverse
bias voltage (-6 V instead of -2 V) to the Ge diode. Despite this
contamination, more than 98% of the background can be rejected while retaining
50% of the signal. This yields a conservative upper limit of 0.7
event.day^{-1}.kg^{-1}.keV^{-1}_{recoil} at 90% confidence level in the 15-45
keV recoil energy interval; the present sensitivity appears to be limited by
the fast ambient neutrons. Upgrades in progress on the installation are
summarized.Comment: Submitted to Astroparticle Physics, 14 page
Les Houches "Physics at TeV Colliders 2003" Beyond the Standard Model Working Group: Summary Report
The work contained herein constitutes a report of the ``Beyond the Standard
Model'' working group for the Workshop "Physics at TeV Colliders", Les Houches,
France, 26 May--6 June, 2003. The research presented is original, and was
performed specifically for the workshop. Tools for calculations in the minimal
supersymmetric standard model are presented, including a comparison of the dark
matter relic density predicted by public codes. Reconstruction of
supersymmetric particle masses at the LHC and a future linear collider facility
is examined. Less orthodox supersymmetric signals such as non-pointing photons
and R-parity violating signals are studied. Features of extra dimensional
models are examined next, including measurement strategies for radions and
Higgs', as well as the virtual effects of Kaluza Klein modes of gluons. An LHC
search strategy for a heavy top found in many little Higgs model is presented
and finally, there is an update on LHC studies.Comment: 113 pages, ed B.C. Allanach, v5 has changes to part XV
The EDELWEISS Experiment : Status and Outlook
The EDELWEISS Dark Matter search uses low-temperature Ge detectors with heat
and ionisation read- out to identify nuclear recoils induced by elastic
collisions with WIMPs from the galactic halo. Results from the operation of 70
g and 320 g Ge detectors in the low-background environment of the Modane
Underground Laboratory (LSM) are presented.Comment: International Conference on Dark Matter in Astro and Particle Physics
(Dark 2000), Heidelberg, Germany, 10-16 Jul 2000, v3 minor revision
- …
