148 research outputs found
Optical systems for high-power laser applications: principles and design aspects
Starting from the optical properties of laser beams, the requirements of optical systems for manipulating laser radiation in industrial applications are derived. The relevant parameters, relations to the diffraction limit and the state-of-the-art design techniques are discussed. The three important types of lasers for use in industrial materials processing operate at wavelengths ranging from the infrared (10.6 μm, CO2 laser; 1.06 μm, Nd:YAG) to the ultraviolet region (excimer lasers). Each wavelength range is associated with specific design challenges. The scarcity of suitable refractive materials for the 10 μm wavelength range and the ultraviolet below 300 nm is a major constraint. Reflective systems are used widely at the longer wavelength, but some designs suffer from coma. The 1.06 μm radiation from the Nd:YAG laser can make use of many well-developed optical means for handling visible light. Energy transport by optical fibres is commonly used. Optical systems for excimer laser applications are specific in that they image a mask onto a workpiece, and use the high photon energy and the high definition possible with the short wavelength for precision micro-machining
Jets and energy flow in photon-proton collisions at HERA
Properties of the hadronic final state in photoproduction events with large transverse energy are studied at the electron-proton collider HERA. Distributions of the transverse energy, jets and underlying event energy are compared to \overline{p}p data and QCD calculations. The comparisons show that the \gamma p events can be consistently described by QCD models including -- in addition to the primary hard scattering process -- interactions between the two beam remnants. The differential jet cross sections d\sigma/dE_T^{jet} and d\sigma/d\eta^{jet} are measured
Разработка интерактивной моделирующей системы технологии низкотемпературной сепарации газа
We present a study of J ψ meson production in collisions of 26.7 GeV electrons with 820 GeV protons, performed with the H1-detector at the HERA collider at DESY. The J ψ mesons are detected via their leptonic decays both to electrons and muons. Requiring exactly two particles in the detector, a cross section of σ(ep → J ψ X) = (8.8±2.0±2.2) nb is determined for 30 GeV ≤ W γp ≤ 180 GeV and Q 2 ≲ 4 GeV 2 . Using the flux of quasi-real photons with Q 2 ≲ 4 GeV 2 , a total production cross section of σ ( γp → J / ψX ) = (56±13±14) nb is derived at an average W γp =90 GeV. The distribution of the squared momentum transfer t from the proton to the J ψ can be fitted using an exponential exp(− b ∥ t ∥) below a ∥ t ∥ of 0.75 GeV 2 yielding a slope parameter of b = (4.7±1.9) GeV −2
Ankle-brachial index as a predictor of coronary disease events in elderly patients submitted to coronary angiography
OBJECTIVES: To correlate the importance of the ankle-brachial index in terms of cardiovascular morbimortality and the extent of coronary arterial disease amongst elderly patients without clinical manifestations of lower limb peripheral arterial disease.METHODS: We analyzed prospective data from 100 patients over 65 years of age with coronary arterial disease, as confirmed by coronary angiography, and with over 70% stenosis of at least one sub-epicardial coronary artery. We measured the ankle-brachial index immediately after coronary angiography, and a value of <0.9 was used to diagnose peripheral arterial disease.RESULTS: the patients' average age was 77.4 years. the most prevalent risk factor was hypertension (96%), and the median late follow-up appointment was 28.9 months. the ankle-brachial index was <0.9 in 47% of the patients, and a low index was more prevalent in patients with multiarterial coronary disease compared to patients with uniarterial disease in the same group. Using a bivariate analysis, only an ankle-brachial index of,0.9 was a strong predictive factor for cardiovascular events, thereby increasing all-cause deaths and fatal and non-fatal acute myocardial infarctions two-to three-fold.CONCLUSION: in elderly patients with documented coronary disease, a low ankle-brachial index (<0.9) was associated with the severity and extent of coronary arterial disease, and in late follow-up appointments, a low index was correlated with an increase in the occurrence of major cardiovascular events.Univ Fed Estado São Paulo, Dept Cardiol, São Paulo, BrazilHosp Israelita Albert Einstein, Dept Cardiol, São Paulo, BrazilDuke Univ, Sch Med, Dept Med, Durham, NC 27706 USAUniv Fed Estado São Paulo, Dept Cardiol, São Paulo, BrazilWeb of Scienc
A Measurement of the Proton Structure Function
A measurement of the proton structure function is reported
for momentum transfer squared between 4.5 and 1600 and
for Bjorken between and 0.13 using data collected by the
HERA experiment H1 in 1993. It is observed that increases
significantly with decreasing , confirming our previous measurement made
with one tenth of the data available in this analysis. The dependence is
approximately logarithmic over the full kinematic range covered. The subsample
of deep inelastic events with a large pseudo-rapidity gap in the hadronic
energy flow close to the proton remnant is used to measure the "diffractive"
contribution to .Comment: 32 pages, ps, appended as compressed, uuencoded fil
- …
