528 research outputs found

    Transcatheter interatrial shunt device for the treatment of heart failure with preserved ejection fraction (REDUCE LAP-HF I [Reduce Elevated Left Atrial Pressure in Patients With Heart Failure]): A phase 2, randomized, sham-controlled trial

    Get PDF
    Background -In non-randomized, open-label studies, a transcatheter interatrial shunt device (IASD, Corvia Medical) was associated with lower pulmonary capillary wedge pressure (PCWP), less symptoms, and greater quality of life and exercise capacity in patients with heart failure (HF) and mid-range or preserved ejection fraction (EF ≥ 40%). We conducted the first randomized, sham-controlled trial to evaluate the IASD in HF with EF ≥ 40%. Methods -REDUCE LAP-HF I was a phase 2, randomized, parallel-group, blinded multicenter trial in patients with New York Heart Association (NYHA) class III or ambulatory class IV HF, EF ≥ 40%, exercise PCWP ≥ 25 mmHg, and PCWP-right atrial pressure gradient ≥ 5 mmHg. Participants were randomized (1:1) to the IASD vs. a sham procedure (femoral venous access with intracardiac echocardiography but no IASD placement). The participants and investigators assessing the participants during follow-up were blinded to treatment assignment. The primary effectiveness endpoint was exercise PCWP at 1 month. The primary safety endpoint was major adverse cardiac, cerebrovascular, and renal events (MACCRE) at 1 month. PCWP during exercise was compared between treatment groups using a mixed effects repeated measures model analysis of covariance that included data from all available stages of exercise. Results -A total of 94 patients were enrolled, of which n=44 met inclusion/exclusion criteria and were randomized to the IASD (n=22) and control (n=22) groups. Mean age was 70±9 years and 50% were female. At 1 month, the IASD resulted in a greater reduction in PCWP compared to sham-control (P=0.028 accounting for all stages of exercise). Peak PCWP decreased by 3.5±6.4 mmHg in the treatment group vs. 0.5±5.0 mmHg in the control group (P=0.14). There were no peri-procedural or 1-month MACCRE in the IASD group and 1 event (worsening renal function) in the control group (P=1.0). Conclusions -In patients with HF and EF ≥ 40%, IASD treatment reduces PCWP during exercise. Whether this mechanistic effect will translate into sustained improvements in symptoms and outcomes requires further evaluation. Clinical Trial Registration -URL: http://clinicaltrials.gov. Unique identifier: NCT02600234

    Modeling the Instantaneous Pressure–Volume Relation of the Left Ventricle: A Comparison of Six Models

    Get PDF
    Simulations are useful to study the heart’s ability to generate flow and the interaction between contractility and loading conditions. The left ventricular pressure–volume (PV) relation has been shown to be nonlinear, but it is unknown whether a linear model is accurate enough for simulations. Six models were fitted to the PV-data measured in five sheep and the estimated parameters were used to simulate PV-loops. Simulated and measured PV-loops were compared with the Akaike information criterion (AIC) and the Hamming distance, a measure for geometric shape similarity. The compared models were: a time-varying elastance model with fixed volume intercept (LinFix); a time-varying elastance model with varying volume intercept (LinFree); a Langewouter’s pressure-dependent elasticity model (Langew); a sigmoidal model (Sigm); a time-varying elastance model with a systolic flow-dependent resistance (Shroff) and a model with a linear systolic and an exponential diastolic relation (Burkh). Overall, the best model is LinFree (lowest AIC), closely followed by Langew. The remaining models rank: Sigm, Shroff, LinFix and Burkh. If only the shape of the PV-loops is important, all models perform nearly identically (Hamming distance between 20 and 23%). For realistic simulation of the instantaneous PV-relation a linear model suffices

    Randomized, double blind study of non-excitatory, cardiac contractility modulation electrical impulses fr symptomatic heart failure

    Get PDF
    AIMS: We performed a randomized, double blind, crossover study of cardiac contractility modulation (CCM) signals in heart failure patients. METHODS AND RESULTS: One hundred and sixty-four subjects with ejection fraction (EF) < 35% and NYHA Class II (24%) or III (76%) symptoms received a CCM pulse generator. Patients were randomly assigned to Group 1 (n = 80, CCM treatment 3 months, sham treatment second 3 months) or Group 2 (n = 84, sham treatment 3 months, CCM treatment second 3 months). The co-primary endpoints were changes in peak oxygen consumption (VO2,peak) and Minnesota Living with Heart Failure Questionnaire (MLWHFQ). Baseline EF (29.3 +/- 6.7% vs. 29.8 +/- 7.8%), VO2,peak (14.1 +/- 3.0 vs. 13.6 +/- 2.7 mL/kg/min), and MLWHFQ (38.9 +/- 27.4 vs. 36.5 +/- 27.1) were similar between the groups. VO2,peak increased similarly in both groups during the first 3 months (0.40 +/- 3.0 vs. 0.37 +/- 3.3 mL/kg/min, placebo effect). During the next 3 months, VO2,peak decreased in the group switched to sham (-0.86 +/- 3.06 mL/kg/min) and increased in patients switched to active treatment (0.16 +/- 2.50 mL/kg/min). MLWHFQ trended better with treatment (-12.06 +/- 15.33 vs. -9.70 +/- 16.71) during the first 3 months, increased during the second 3 months in the group switched to sham (+4.70 +/- 16.57), and decreased further in patients switched to active treatment (-0.70 +/- 15.13). A comparison of values at the end of active treatment periods vs. end of sham treatment periods indicates statistically significantly improved VO2,peak and MLWHFQ (P = 0.03 for each parameter). CONCLUSION: In patients with heart failure and left ventricular dysfunction, CCM signals appear safe; exercise tolerance and quality of life (MLWHFQ) were significantly better while patients were receiving active treatment with CCM for a 3-month period

    Minimally invasive, patient specific, beat-by-beat estimation of left ventricular time varying elastance.

    Full text link
    peer reviewedBACKGROUND: The aim of this paper was to establish a minimally invasive method for deriving the left ventricular time varying elastance (TVE) curve beat-by-beat, the monitoring of which's inter-beat evolution could add significant new data and insight to improve diagnosis and treatment. The method developed uses the clinically available inputs of aortic pressure, heart rate and baseline end-systolic volume (via echocardiography) to determine the outputs of left ventricular pressure, volume and dead space volume, and thus the TVE curve. This approach avoids directly assuming the shape of the TVE curve, allowing more effective capture of intra- and inter-patient variability. RESULTS: The resulting TVE curve was experimentally validated against the TVE curve as derived from experimentally measured left ventricular pressure and volume in animal models, a data set encompassing 46,318 heartbeats across 5 Pietrain pigs. This simulated TVE curve was able to effectively approximate the measured TVE curve, with an overall median absolute error of 11.4% and overall median signed error of -2.5%. CONCLUSIONS: The use of clinically available inputs means there is potential for real-time implementation of the method at the patient bedside. Thus the method could be used to provide additional, patient specific information on intra- and inter-beat variation in heart function

    Resting and exercise haemodynamic characteristics of patients with advanced heart failure and preserved ejection fraction

    Get PDF
    Aims: This study aimed to describe haemodynamic features of patients with advanced heart failure with preserved ejection fraction (HFpEF) as defined by the Heart Failure Association (HFA) of the European Society of Cardiology (ESC). Methods and results: We used pooled data from two dedicated HFpEF studies with invasive exercise haemodynamic protocols, the REDUCE LAP-HF (Reduce Elevated Left Atrial Pressure in Patients with Heart Failure) trial and the REDUCE LAP-HF I trial, and categorized patients according to advanced heart failure (AdHF) criteria. The well-characterized HFpEF patients were considered advanced if they had persistent New York Heart Association classification of III–IV and heart failure (HF) hospitalization &lt; 12 months and a 6 min walk test distance &lt; 300 m. Twenty-four (22%) out of 108 patients met the AdHF criteria. On evaluation, clinical characteristics and resting haemodynamics were not different in the two groups. Patients with AdHF had lower work capacity compared with non-advanced patients (35 ± 16 vs. 45 ± 18 W, P = 0.021). Workload-corrected pulmonary capillary wedge pressure normalized to body weight (PCWL) was higher in AdHF patients compared with non-advanced (112 ± 55 vs. 86 ± 49 mmHg/W/kg, P = 0.04). Further, AdHF patients had a smaller increase in cardiac index during exercise (1.1 ± 0.7 vs. 1.6 ± 0.9 L/min/m2, P = 0.028). Conclusions: A significantly higher PCWL and lower cardiac index reserve during exercise were observed in AdHF patients compared with non-advanced. These differences were not apparent at rest. Therapies targeting the haemodynamic compromise associated with advanced HFpEF are needed

    Invasive left ventricle pressure-volume analysis: overview and practical clinical implications

    Get PDF
    Ventricular pressure-volume (PV) analysis is the reference method for the study of cardiac mechanics. Advances in calibration algorithms and measuring techniques brought new perspectives for its application in different research and clinical settings. Simultaneous PV measurement in the heart chambers offers unique insights into mechanical cardiac efficiency. Beat to beat invasive PV monitoring can be instrumental in the understanding and management of heart failure, valvular heart disease, and mechanical cardiac support. This review focuses on intra cardiac left ventricular PV analysis principles, interpretation of signals, and potential clinical applications

    Cardiac MR Elastography: Comparison with left ventricular pressure measurement

    Get PDF
    Purpose of the Study: To compare magnetic resonance elastography (MRE) with ventricular pressure changes in an animal model. Methods: Three pigs of different cardiac physiology (weight, 25 to 53 kg; heart rate, 61 to 93 bpm; left ventricular [LV] end-diastolic volume, 35 to 70 ml) were subjected to invasive LV pressure measurement by catheter and noninvasive cardiac MRE. Cardiac MRE was performed in a short-axis view of the heart and applying a 48.3-Hz shear-wave stimulus. Relative changes in LV-shear wave amplitudes during the cardiac cycle were analyzed. Correlation coefficients between wave amplitudes and LV pressure as well as between wave amplitudes and LV diameter were determined. Results: A relationship between MRE and LV pressure was observed in all three animals (R-square [greater than or equal to] 0.76). No correlation was observed between MRE and LV diameter (R-square [less than or equal to] 0.15). Instead, shear wave amplitudes decreased 102 +/- 58 ms earlier than LV diameters at systole and amplitudes increased 175 +/- 40 ms before LV dilatation at diastole. Amplitude ratios between diastole and systole ranged from 2.0 to 2.8, corresponding to LV pressure differences of 60 to 73 mmHg. Conclusion: Externally induced shear waves provide information reflecting intraventricular pressure changes which, if substantiated in further experiments, has potential to make cardiac MRE a unique noninvasive imaging modality for measuring pressure-volume function of the heart
    corecore