413 research outputs found

    Evaluation of omniweave reinforcement for composite fabrication

    Get PDF
    Molded composites made from type-2 Morganite and/or boron are suitable for structural skins. Layered-in-depth omniweave construction yields higher in-plane strength characteristics than fiber-pitch angle construction, and strength and moduli data vary with fiber orientation

    Treatment with Haemodiafiltration Stabilises Vascular Stiffness (Measured by Aortic Pulse Wave Velocity) Compared to Haemodialysis.

    Get PDF
    Background/Aims: Cerebrovascular diseases such as stroke are increased in dialysis patients, and haemodiafiltration has been reported to reduce cerebrovascular mortality compared to haemodialysis. We wished to determine whether haemodiafiltration improves arterial stiffness. Methods: We audited aortic pulse wave velocity (PWV) measurements 6 months apart in 3 cohorts of patients: 69 treated with haemodialysis, 78 who converted from haemodialysis to haemodiafiltration and 142 treated with haemodiafiltration. Results: Cohorts were well matched for age (means ± SD: haemodialysis 64 ± 15 years vs. haemodialysis to haemodiafiltration 64 ± 17 years vs. haemodiafiltration 67 ± 16 years), sex (male 65 vs. 59 vs. 63%), diabetes (45 vs. 56.4 vs. 44%) and body mass index (26 ± 6 vs. 26 ± 5 vs. 26 ± 5), respectively. Systolic blood pressure did not differ over time (haemodialysis 143 ± 25 vs. 146 ± 27 mm Hg, haemodialysis to haemodiafiltration 153 ± 26 vs. 154 ± 25 mm Hg, haemodiafiltration 149 ± 31 vs. 148 ± 30 mm Hg) or between groups. Aortic PWV significantly increased in the haemodialysis group (9.5 ± 1.9 vs. 10.2 ± 2.2 m/s, p < 0.01) and haemodialysis to haemodiafiltration group (9.4 ± 1.9 vs. 10.1 ± 2.2 m/s, p < 0.01), but did not change with haemodiafiltration (9.9 ± 2.1 vs. 10.1 ± 2.2 m/s). Conclusions: Aortic PWV, a measure of vascular stiffness, stabilised with haemodiafiltration. Our preliminary findings require further investigation to determine how haemodiafiltration may potentially improve vascular stiffness. © 2014 S. Karger AG, Basel

    Empathy at Play:Embodying Posthuman Subjectivities in Gaming

    Get PDF
    In this article, we address the need for a posthuman account of the relationship between the avatar and player. We draw on a particular line of posthumanist theory associated closely with the work of Karen Barad, Rosi Braidotti and N. Katherine Hayles that suggests a constantly permeable, fluid and extended subjectivity, displacing the boundaries between human and other. In doing so, we propose a posthuman concept of empathy in gameplay, and we apply this concept to data from the first author’s 18-month ethnographic field notes of gameplay in the MMORPG World of Warcraft. Exploring these data through our analysis of posthuman empathy, we demonstrate the entanglement of avatar–player, machine–human relationship. We show how empathy allows us to understand this relationship as constantly negotiated and in process, producing visceral reactions in the intra-connected avatar–player subject as well as moments of co-produced in-game action that require ‘affective matching’ between subjective and embodied experiences. We argue that this account of the avatar–player relationship extends research in game culture, providing a horizontal, non-hierarchical discussion of its most necessary interaction

    Spirometric changes in obstructive disease: after all, how much is significant?

    Get PDF
    OBJECTIVE: To establish the upper limits for changes in FEV1, slow vital capacity (SVC), FVC, and inspiratory capacity (IC) after placebo administration in patients with airflow obstruction. METHODS: One hundred and two adults with airflow obstruction (FEV1 = 62 ± 19% of predicted) were included in the study. All of the participants performed SVC and FVC maneuvers before and after the administration of placebo spray. The changes in FEV1, SVC, FVC, and IC were expressed as absolute values, percentage of change from baseline values, and percentage of predicted values, 95% CIs and 95th percentiles being calculated. Factor analysis was performed in order to determine how those changes clustered. RESULTS: Considering the 95% CIs and 95th percentiles and after rounding the values, we found that the upper limits for a significant response were as follows: FEV1 = 0.20 L, FVC = 0.20 L, SVC = 0.25 L, and IC = 0.30 L (expressed as absolute values); FEV1 = 12%, FVC = 7%, SVC = 10%, and IC = 15% (expressed as percentage of change from baseline values); and FEV1 = 7%, FVC = 6%, SVC = 7%, and IC = 12% (expressed as percentage of predicted values). CONCLUSIONS: In patients with airflow obstruction, IC varies more widely than do FVC and SVC. For IC, values greater than 0.30 L and 15% of change from the baseline value can be considered significant. For FVC, values greater than 0.20 L and 7% of change from the baseline value are significant. Alternatively, changes exceeding 0.20 L and 7% of the predicted value can be considered significant for FEV1 and FVC. On factor analysis, spirometric parameters clustered into three dimensions, expressing changes in flows, volumes, and dynamic hyperinflation.OBJETIVO: Estabelecer os limites superiores para mudanças em VEF1, capacidade vital lenta (CVL), CVF e capacidade inspiratória (CI) após o uso de placebo em pacientes com obstrução ao fluxo aéreo. MÉTODOS: Cento e dois adultos com obstrução ao fluxo aéreo (VEF1 = 62 ± 19% do previsto) foram incluídos neste estudo. Todos os participantes realizaram manobras de CVL e CVF antes e depois do uso de spray de placebo. As mudanças em VEF1, CVL, CVF e CI foram expressas em valores absolutos, porcentagem de variação em relação aos valores basais e porcentagem dos valores previstos, e foram calculados os IC95% e os percentis 95. A análise fatorial foi realizada a fim de determinar como essas alterações se agrupavam. RESULTADOS: Considerando os IC95% e percentis 95 e após o arredondamento dos valores, obtivemos os seguintes limites superiores para resposta significante: VEF1 = 0,20 L, CVF = 0,20 L, CVL = 0,25 L e CI = 0,30 L (em valores absolutos); VEF1 = 12%, CVF = 7%, CVL = 10% e CI = 15% (em porcentagem de variação em relação aos valores basais) e VEF1 = 7%, CVF = 6%, CVL = 7% e CI = 12% (em porcentagem dos valores previstos). CONCLUSÕES: Em pacientes com obstrução ao fluxo aéreo, a CI apresenta maior variabilidade do que a CVF e a CVL. Para a CI, valores maiores que 0,30 L e 15% de variação em relação ao valor basal devem ser considerados significantes. Para CVF, valores maiores que 0,20L e 7% de variação em relação ao valor basal são significantes. Alternativamente, alterações de mais de 0,20 L e 7% do previsto no VEF1 e na CVF devem ser consideradas significantes. Na análise fatorial, os parâmetros espirométricos se agruparam em três dimensões, expressando mudanças no fluxo, volume e hiperinsuflação dinâmica.Universidade Federal do Rio Grande do NorteUniversidade Federal de São Paulo (UNIFESP)Hospital do Servidor Público Estadual de São PauloUNIFESPSciEL

    The effect of different dosing regimens of motesanib on the gallbladder: a randomized phase 1b study in patients with advanced solid tumors

    Get PDF
    Extent: 11 p.BACKGROUND: Gallbladder toxicity, including cholecystitis, has been reported with motesanib, an orally administered small-molecule antagonist of VEGFRs 1, 2 and 3; PDGFR; and Kit. We assessed effects of motesanib on gallbladder size and function. METHODS: Patients with advanced metastatic solid tumors ineligible for or progressing on standard-of-care therapies with no history of cholecystitis or biliary disease were randomized 2:1:1 to receive motesanib 125 mg once daily (Arm A); 75 mg twice daily (BID), 14-days-on/7-days-off (Arm B); or 75 mg BID, 5-days-on/2-days-off (Arm C). Primary endpoints were mean change from baseline in gallbladder size (volume by ultrasound; independent review) and function (ejection fraction by CCK-HIDA; investigator assessment). RESULTS: Forty-nine patients received ≥1 dose of motesanib (Arms A/B/C, n = 25/12/12). Across all patients, gallbladder volume increased by a mean 22.2 cc (from 38.6 cc at baseline) and ejection fraction decreased by a mean 19.2% (from 61.3% at baseline) during treatment. Changes were similar across arms and appeared reversible after treatment discontinuation. Three patients had cholecystitis (grades 1, 2, 3, n = 1 each) that resolved after treatment discontinuation, one patient developed grade 3 acute cholecystitis requiring cholecystectomy, and two patients had other notable grade 1 gallbladder disorders (gallbladder wall thickening, gallbladder dysfunction) (all in Arm A). Two patients developed de novo gallstones during treatment. Twelve patients had right upper quadrant pain (Arms A/B/C, n = 8/1/3). The incidence of biliary “sludge” in Arms A/B/C was 39%/36%/27%. CONCLUSION: Motesanib treatment was associated with increased gallbladder volume, decreased ejection fraction, biliary sludge, gallstone formation, and infrequent cholecystitis. Trial registration: ClinicalTrials.gov NCT00448786Lee S. Rosen, Lara Lipton, Timothy J. Price, Neil D. Belman, Ralph V. Boccia, Herbert I. Hurwitz, Joe J. Stephenson Jr., Lori J. Wirth, Sheryl McCoy, Yong-jiang Hei, Cheng-Pang Hsu and Niall C. Tebbut

    Short-term acclimation in adults does not predict offspring acclimation potential to hypoxia

    Get PDF
    Abstract The prevalence of hypoxic areas in coastal waters is predicted to increase and lead to reduced biodiversity. While the adult stages of many estuarine invertebrates can cope with short periods of hypoxia, it remains unclear whether that ability is present if animals are bred and reared under chronic hypoxia. We firstly investigated the effect of moderate, short-term environmental hypoxia (40% air saturation for one week) on metabolic performance in adults of an estuarine amphipod, and the fitness consequences of prolonged exposure. We then reared the offspring of hypoxia-exposed parents under hypoxia, and assessed their oxyregulatory ability under declining oxygen tensions as juveniles and adults. Adults from the parental generation were able to acclimate their metabolism to hypoxia after one week, employing mechanisms typically associated with prolonged exposure. Their progeny, however, did not develop the adult pattern of respiratory regulation when reared under chronic hypoxia, but instead exhibited a poorer oxyregulatory ability than their parents. We conclude that species apparently hypoxia-tolerant when tested in short-term experiments, could be physiologically compromised as adults if they develop under hypoxia. Consequently, we propose that the increased prevalence of hypoxia in coastal regions will have marked effects in some species currently considered hypoxia tolerant

    Identificación de equipos y procedimientos utilizados por fisioterapeutas brasileños para pruebas de endurance muscular inspiratoria

    Get PDF
    A avaliação da função dos músculos inspiratórios por meio do teste de endurance muscular inspiratória (EMI), definida como a capacidade de sustentação dessa tarefa ao longo do tempo, atualmente apresenta ampla variedade de instrumentos e procedimentos para sua mensuração. Este estudo teve como objetivo identificar os diferentes equipamentos, procedimentos e forma de avaliação dos testes de EMI entre fisioterapeutas brasileiros. É um estudo transversal realizado por meio de questionário enviado por correio eletrônico individualmente a cada participante. Cento e treze fisioterapeutas de diferentes regiões do país, grande parte com atuação conjunta na clínica e na docência (52,1%), responderam realizar poucas vezes a medida de EMI (48,7%). O manovacuômetro aneroide foi o aparelho mais utilizado por 42,5% dos profissionais. O clipe nasal e o bocal tubular de plástico rígido ou papel foram os acessórios mais utilizados durante o teste, correspondendo a 51,8% e 33%, respectivamente. O teste de ventilação voluntária máxima foi o mais utilizado para avaliação da endurance inspiratória, relatado por 23% dos respondentes. O teste de carga constante para avaliação da endurance foi adotado por 51,2% dos fisioterapeutas, sendo que 54,9% associaram comandos verbais à demonstração para explicação do teste. A interpretação dos valores aferidos era feita através de valores de referência por 25,7% dos entrevistados. Identificou-se que os fisioterapeutas brasileiros entrevistados não apresentaram a mesma conduta para os testes de EMI. No entanto os equipamentos, procedimentos e a forma de avaliação são utilizados com base nas diretrizes sobre o tema e de acordo com a disponibilidade de recursos do serviço.La evaluación de la función de los músculos inspiratorios a través del entrenamiento muscular inspiratorio (EMI), definida como la capacidad de sustentación de esta tarea a lo largo del tiempo, actualmente presenta una amplia variedad de instrumentos y procedimientos para su medición. Este estudio tuvo como objetivo identificar los diferentes equipos, procedimientos y forma de evaluación de las pruebas de EMI entre fisioterapeutas brasileños. Es un estudio transversal realizado por medio de un cuestionario enviado por correo electrónico a cada participante. Ciento trece fisioterapeutas de diferentes regiones del país, que en gran parte actúan a la vez en la clínica y en la enseñanza (52,1%), dijeron realizar pocas veces la medida de EMI (48,7%). El manovacuómetro aneroide fue el aparato más utilizado por el 42,5% de los profesionales. El clip nasal y la boquilla tubular de plástico rígido o papel fueron los accesorios más utilizados durante la prueba, correspondiendo al 51,8% y al 33%, respectivamente. La prueba de ventilación voluntaria máxima fue la más utilizada para la evaluación de la resistencia respiratoria, reportada por el 23% de los entrevistados. La prueba de carga constante para la evaluación de la resistencia se adoptó por el 51,2% de los fisioterapeutas, siendo que el 54,9% asoció comandos verbales a la demostración para la explicación de la prueba. La interpretación de los valores evaluados se hacía a través de valores de referencia por el 25,7% de los entrevistados. Se identificó que los fisioterapeutas brasileños entrevistados no presentaron la misma conducta para las pruebas de EMI. Sin embargo, los equipos, procedimientos y la forma de evaluación se utilizan con base en las directrices sobre el tema y de acuerdo con la disponibilidad de recursos del servicio.The assessment of inspiratory muscles through the inspiratory muscle endurance test (IME), defined as the ability to support this task over time, currently presents wide range of instruments and procedures for its measurement. This study aimed to identify the different equipment, procedures and assessments of IME tests among Brazilian physical therapists. It is a cross-sectional study carried out through a questionnaire sent individually by electronic mail to each participant. One hundred and thirteen physical therapists from different regions of the country, many practicing in the clinic and in the teaching field (52.1%), said they measured IME a few times (48.7%). The aneroid manovacuometer was used by 42.5% of the professionals. The nose clip and the hard plastic or paper tubular incentive spirometer were the most used accessories during the test, corresponding to 51.8% and 33%, respectively. The maximum voluntary ventilation test was used to assess the inspiratory endurance, reported by 23% of the respondents. The constant load test for endurance assessment was adopted by 51.2% of the physical therapists, and 54.9% associated verbal commands with the demonstration for the test application. The interpretation of the measured values was made with reference values by 25.7% of respondents. We identified that Brazilian physical therapists interviewed did not show the same conduct for IME tests. However, the equipment, procedures and assessment form are used based on the guidelines on the subject and according to the availability of resources of the service

    Co-designing Cards on Social Issues for Creating Educational Games

    Get PDF
    This paper presents a participatory methodology to design cards on social issues with the purpose to democratise knowledge among co-designers on the learning content of educational games. Situated on the topic of everyday sexism, the methodology has been developed through an iterative process involving two collaborative workshops, two iterations of card design and a feedback survey. Extracting findings from the workshops and the feedback gathered on the co- designed cards, this paper presents insights that could be used to inform similar studies using cards to inspire and foster reflection on social issues
    corecore