104 research outputs found

    An experimental simulation model to assess wear of the porcine patellofemoral joint

    Get PDF
    A range of surgical techniques and osteochondral interventions have been developed for early stage chondral/osteochondral repair interventions in the knee however, methods for functional, pre-clinical assessment of these therapies are limited. In this study, a method for simulating physiological loading and motion in the porcine patellofemoral joint was developed using a 6-axis simulator. As an example of how the method can be used, the influence of surgical positioning of osteochondral allografts in the patella on cartilage wear, deformation and damage and graft stability was investigated in this porcine patellofemoral joint model. The functional performance of allografts implanted either optimally (flush with the cartilage surface) or 1 mm proud of the cartilage surface was compared to a positive control (stainless steel pin implanted 1 mm proud of the cartilage surface), a negative control (no intervention) and a defect model. Allografts implanted flush with the surrounding cartilage could restore the articulating surface of the patella resulting in low wear, damage and deformation of the opposing cartilage surface, similar to that of the negative control group. Implanting the graft proud of the patella surface resulted in cartilage lesions on the femoral trochlea (ICRS grade 2) and a cartilage volume difference of 2.0 ± 3.9 mm3; the positive controls resulted in more severe lesions, a higher volume difference (14.2 ± 7.4 mm3) which in some cases exposed subchondral bone (ICRS grade 4). Defects in the patella caused deformation of the opposing cartilage surface. All grafts implanted in the patella subsided over the duration of the study. This study demonstrated a method that can be used to evaluate osteochondral repair strategies in the patellofemoral joint applying physiological loading and motions

    Development of Population Tariffs for the CarerQol Instrument for Hungary, Poland and Slovenia

    Get PDF
    __Background:__ The CarerQol instrument can be used in economic evaluations to measure the care-related quality of life of informal caregivers. Tariff sets are available for Australia, Germany, Sweden, the Netherlands, the UK, and the USA. __Objective:__ Our objective was to develop tariff sets for the CarerQol instrument for Hungary, Poland and Slovenia and to compare these with the existing value sets. __Methods:__ Discrete-choice experiments were carried out in Hungary, Poland and Slovenia. Data were collected through an online survey between November 2018 and January 2019, using representative samples of 1000 respondents per country. Tariffs were calculated from coefficient estimates from panel mixed multinomial logit models with random parameters. __Results:__ All seven CarerQol domains contributed significantly to the utility associated with different caregiving situations. Attributes valued highest were ‘physical health

    Reliability analysis of moment redistribution in reinforced concrete beams

    Get PDF
    Design codes allow a limited amount of moment redistribution in continuous reinforced concrete beams and often make use of lower bound values in the procedure for estimating the moment redistribution factors. Here, based on the concept of demand and capacity rotation, and by means of Monte Carlo simulation, a probabilistic model is derived for the evaluation of moment redistribution factors. Results show that in all considered cases, the evaluated mean and nominal values of moment redistribution factor are greater than the values provided by the ACI code. On the other hand, the 5th percentile value of moment redistribution factor could be lower than those specified by the code. Although the reduction of strength limit state reliability index attributable to uncertainty in moment redistribution factors is not large, it is comparable to the reduction in reliability index resulting from increasing the ratio of live to dead load

    Comparative efficacy and safety of biosimilar infliximab and other biological treatments in ankylosing spondylitis: systematic literature review and meta-analysis.

    Get PDF
    OBJECTIVES: To compare the efficacy and safety of infliximab-biosimilar with other biological drugs for the treatment of active ankylosing spondylitis (AS). METHODS: Systematic literature review for randomized controlled trials (RCTs) with adalimumab, etanercept, golimumab, infliximab and infliximab-biosimilar in AS was performed and indirect meta-analysis (Bayesian mixed treatment comparison) was carried out. The proportion of patients reaching 20 % improvement by the assessment of Spondyloarthritis International Society response criteria (ASAS20) at weeks 12 and 24 was used as efficacy endpoints, and the occurrence of serious adverse events at week 24 was applied to compare the safety of the biologicals. RESULTS: Altogether, 13 RCTs, identified by the systematic literature search, were included in the analysis. Results on the ASAS20 efficacy endpoint were reported for week 12 in 12 RCTs involving 2,395 patients, and for week 24 in 5 RCTs comprising 1,337 patients. All the five biological agents proved to be significantly superior to placebo. Infliximab showed the highest odds ratio (OR) of 7.2 (95 % CI 3.68-13.19) compared to placebo, followed by infliximab-biosimilar with OR 6.25 (95 % CI 2.55-13.14), both assessed at week 24. No significant difference was found between infliximab-biosimilar and other biological treatments regarding their efficacy and safety. CONCLUSIONS: This is the first study which includes a biosimilar drug in the meta-analysis of biological treatments in AS. The results have proven the similar efficacy and safety profile of infliximab-biosimilar treatment compared to other biologicals

    Use of facile mechanochemical method to functionalize carbon nanofibers with nanostructured polyaniline and their electrochemical capacitance

    Get PDF
    A facile approach to functionalize carbon nanofibers [CNFs] with nanostructured polyaniline was developed via in situ mechanochemical polymerization of polyaniline in the presence of chemically treated CNFs. The nanostructured polyaniline grafting on the CNF was mainly in a form of branched nanofibers as well as rough nanolayers. The good dispersibility and processability of the hybrid nanocomposite could be attributed to its overall nanostructure which enhanced its accessibility to the electrolyte. The mechanochemical oxidation polymerization was believed to be related to the strong Lewis acid characteristic of FeCl3 and the Lewis base characteristic of aniline. The growth mechanism of the hierarchical structured nanofibers was also discussed. After functionalization with the nanostructured polyaniline, the hybrid polyaniline/CNF composite showed an enhanced specific capacitance, which might be related to its hierarchical nanostructure and the interaction between the aromatic polyaniline molecules and the CNFs

    EQ-5D in Central and Eastern Europe : 2000-2015

    Get PDF
    Objective: Cost per quality-adjusted life year data are required for reimbursement decisions in many Central and Eastern European (CEE) countries. EQ-5D is by far the most commonly used instrument to generate utility values in CEE. This study aims to systematically review the literature on EQ-5D from eight CEE countries. Methods: An electronic database search was performed up to July 1, 2015 to identify original EQ-5D studies from the countries of interest. We analysed the use of EQ-5D with respect to clinical areas, methodological rigor, population norms and value sets. Results: We identified 143 studies providing 152 country-specific results with a total sample size of 81,619: Austria (n=11), Bulgaria (n=6), Czech Republic (n=18), Hungary (n=47), Poland (n=51), Romania (n=2), Slovakia (n=3) and Slovenia (n=14). Cardiovascular (20%), neurologic (16%), musculoskeletal (15%) and endocrine/nutritional/metabolic diseases (14%) were the most frequently studied clinical areas. Overall 112 (78%) of the studies reported EQ VAS results and 86 (60%) EQ-5D index scores, of which 27 (31%) did not specify the applied tariff. Hungary, Poland and Slovenia have population norms. Poland and Slovenia also have a national value set. Conclusions: Increasing use of EQ-5D is observed throughout CEE. The spread of health technology assessment activities in countries seems to be reflected in the number of EQ-5D studies. However, improvement in informed use and methodological quality of reporting is needed. In jurisdictions where no national value set is available, in order to ensure comparability we recommend to apply the most frequently used UK tariff. Regional collaboration between CEE countries should be strengthened

    Inequalities in medicine use in Central Eastern Europe: an empirical investigation of socioeconomic determinants in eight countries

    Full text link

    Enhancement strategies for transdermal drug delivery systems: current trends and applications

    Get PDF

    Calcium orthophosphate-based biocomposites and hybrid biomaterials

    Full text link
    corecore