847 research outputs found

    Decentralized Triangular Guidance Algorithms for Formations of UAVs

    Get PDF
    This paper deals with the design of a guidance control system for a swarm of unmanned aerial systems flying at a given altitude, addressing flight formation requirements that can be formulated constraining the swarm to be on the nodes of a triangular mesh. Three decentralized guidance algorithms are presented. A classical fixed leader–follower scheme is compared with two alternative schemes: the former is based on the self-identification of one or more time-varying leaders; the latter is an algorithm without leaders. Several operational scenarios have been simulated involving swarms with obstacles and an increasing number of aircraft in order to prove the effectiveness of the proposed guidance schem

    Tuning a Resonance in the Fock Space: Optimization of Phonon Emission in a Resonant Tunneling Device

    Full text link
    Phonon-assisted tunneling in a double barrier resonant tunneling device can be seen as a resonance in the electron-phonon Fock space which is tuned by the applied voltage. We show that the geometrical parameters can induce a symmetry condition in this space that can strongly enhance the emission of longitudinal optical phonons. For devices with thin emitter barriers this is achieved by a wider collector's barrier.Comment: 4 pages, 3 figures. Figure 1 changed, typos correcte

    Approximate Analytical Model for the Squeeze-Film Lubrication of the Human Ankle Joint with Synovial Fluid Filtrated by Articular Cartilage

    Get PDF
    The aim of this article is to propose an analytical approximate squeeze-film lubrication model of the human ankle joint for a quick assessment of the synovial pressure field and the load carrying due to the squeeze motion. The model starts from the theory of boosted lubrication for the human articular joints lubrication (Walker et al., Rheum Dis 27:512–520, 1968; Maroudas, Lubrication and wear in joints. Sector, London, 1969) and takes into account the fluid transport across the articular cartilage using Darcy’s equation to depict the synovial fluid motion through a porous cartilage matrix. The human ankle joint is assumed to be cylindrical enabling motion in the sagittal plane only. The proposed model is based on a modified Reynolds equation; its integration allows to obtain a quick assessment on the synovial pressure field showing a good agreement with those obtained numerically (Hlavacek, J Biomech 33:1415–1422, 2000). The analytical integration allows the closed form description of the synovial fluid film force and the calculation of the unsteady gap thickness

    Kondo resonances and Fano antiresonances in transport through quantum dots

    Full text link
    The transmission of electrons through a non-interacting tight-binding chain with an interacting side quantum dot (QD) is analized. When the Kondo effect develops at the dot the conductance presents a wide minimum, reaching zero at the unitary limit. This result is compared to the opposite behaviour found in an embedded QD. Application of a magnetic field destroys the Kondo effect and the conductance shows pairs of dips separated by the charging energy U. The results are discussed in terms of Fano antiresonances and explain qualitatively recent experimental results.Comment: 4 pages including 4 figure

    Volumetric Segmentation of Pelvic Organs from MRI Acquisitions

    Get PDF
    In this work we present part of a Pelvis Dynamics Modeling System for pre-surgical assistance in the pelvic organ prolapse disease. In this condition, the most common affected organs are the uterus, the bladder and the rectum. The Magnetic Resonance Imaging (MRI) is the gold standard non-invasive imaging technique to evaluate this condition. The MRI’s acquisitions provide spatial information that is essential to build tri-dimensional (3D) models and run physical simulations that recreate the prolapse. In these acquisitions, the above mentioned organs, present blurred borders and different textures. Therefore, its extraction in not trivial at all. We pose an hybrid semi-automatic segmentation strategy which combines Region Growing (RG) and Active Surfaces in MRI scans to retrieve surface meshes of the organs of interest. We show some real cases, one applying the complete process in detail and the others, providing final results attained by the method which shows high quality segmentations achieved with a low computational cost.Sociedad Argentina de Informática e Investigación Operativ

    Time evolution of stimulated Raman scattering and two-plasmon decay at laser intensities relevant for shock ignition in a hot plasma

    Get PDF
    Laser–plasma interaction (LPI) at intensities 1015–1016 W cm2 is dominated by parametric instabilities which can be responsible for a significant amount of non-collisional absorption and generate large fluxes of high-energy nonthermal electrons. Such a regime is of paramount importance for inertial confinement fusion (ICF) and in particular for the shock ignition scheme. In this paper we report on an experiment carried out at the Prague Asterix Laser System (PALS) facility to investigate the extent and time history of stimulated Raman scattering (SRS) and two-plasmon decay (TPD) instabilities, driven by the interaction of an infrared laser pulse at an intensity 1:2 1016 W cm2 with a 100 mm scalelength plasma produced from irradiation of a flat plastic target. The laser pulse duration (300 ps) and the high value of plasma temperature (4 keV) expected from hydrodynamic simulations make these results interesting for a deeper understanding of LPI in shock ignition conditions. Experimental results show that absolute TPD/SRS, driven at a quarter of the critical density, and convective SRS, driven at lower plasma densities, are well separated in time, with absolute instabilities driven at early times of interaction and convective backward SRS emerging at the laser peak and persisting all over the tail of the pulse. Side-scattering SRS, driven at low plasma densities, is also clearly observed. Experimental results are compared to fully kinetic large-scale, two-dimensional simulations. Particle-in-cell results, beyond reproducing the framework delineated by the experimental measurements, reveal the importance of filamentation instability in ruling the onset of SRS and stimulated Brillouin scattering instabilities and confirm the crucial role of collisionless absorption in the LPI energy balance

    Effect of aspirin on the diagnostic accuracy of the faecal immunochemical test for colorectal advanced neoplasia

    Get PDF
    Background: Aspirin (ASA) is a drug that can cause gastrointestinal lesions and symptoms. Colorectal cancer (CRC) is the most prevalent type of cancer in Western countries. We assessed the effect of aspirin on the diagnostic accuracy of the faecal immunochemical test (FIT) for CRC and/or advanced neoplasia (AN) in patients undergoing colonoscopy for gastrointestinal symptoms. Methods: We conducted a prospective multicentre observational study of diagnostic tests that included patients with gastrointestinal symptoms undergoing colonoscopy between March 2012 and 2014 (the COLONPREDICT study). Symptoms were assessed and a FIT and blood tests assessing haemoglobin and carcinoembryonic antigen (CEA) levels were performed. Results: The study included 3052 patients: A total of 2567 did not take aspirin (non-user group) and 485 (16%) took aspirin (user group). Continuous treatment with ASA did not change the AUC (0.88, 0.82; p = 0.06), sensitivity (92%, 88%; p = 0.5) or specificity (71%, 67%; p = 0.2) of the FIT for CRC detection. Similarly, we found no differences in the AUC (0.81, 0.79; p = 0.6), sensitivity (74%, 75.5%; p = 0.3) or specificity (76%, 73.6%; p = 0.3) for AN detection. Patients with an aspirin use of = 300 mg/day had a lower prevalence of AN and the sensitivity, specificity and AUC for AN for these patients were 54%, 68% and 0.66, significantly lower than for the non-user group (p = 0.03). Conclusions: Aspirin does not modify the diagnostic accuracy of FIT for CRC and/or AN in patients with gastrointestinal symptoms. Aspirin use of = 300 mg/day decreases the accuracy of the test
    • …
    corecore