206 research outputs found
Scintillation efficiency of liquid argon in low energy neutron-argon scattering
Experiments searching for weak interacting massive particles with noble gases
such as liquid argon require very low detection thresholds for nuclear recoils.
A determination of the scintillation efficiency is crucial to quantify the
response of the detector at low energy. We report the results obtained with a
small liquid argon cell using a monoenergetic neutron beam produced by a
deuterium-deuterium fusion source. The light yield relative to electrons was
measured for six argon recoil energies between 11 and 120 keV at zero electric
drift field.Comment: 21 pages, 19 figures, 4 table
Study of nuclear recoils in liquid argon with monoenergetic neutrons
For the development of liquid argon dark matter detectors we assembled a
setup in the laboratory to scatter neutrons on a small liquid argon target. The
neutrons are produced mono-energetically (E_kin=2.45 MeV) by nuclear fusion in
a deuterium plasma and are collimated onto a 3" liquid argon cell operating in
single-phase mode (zero electric field). Organic liquid scintillators are used
to tag scattered neutrons and to provide a time-of-flight measurement. The
setup is designed to study light pulse shapes and scintillation yields from
nuclear and electronic recoils as well as from {\alpha}-particles at working
points relevant to dark matter searches. Liquid argon offers the possibility to
scrutinise scintillation yields in noble liquids with respect to the
populations of the two fundamental excimer states. Here we present experimental
methods and first results from recent data towards such studies.Comment: 9 pages, 8 figures, proceedings of TAUP 2011, to be published in
Journal of Physics: Conference Series (JCPS
Warm Compressor system Overview and status of the PIP-II cryogenic system
The Proton Improvement Plan-II (PIP-II) is a major upgrade to the Fermilab
accelerator complex, featuring a new 800-MeV Superconducting Radio-Frequency
(SRF) linear accelerator (Linac) powering the accelerator complex to provide
the world's most intense high-energy neutrino beam. The PIP-II Linac consists
of 23 SRF cryomodules operating at 2 K, 5 K, and 40 K temperature levels
supplied by a single helium cryoplant providing 2.5 kW of cooling capacity at
2.0 K. The PIP-II cryogenic system consists of two major systems: a helium
cryogenic plant and a cryogenic distribution system. The cryogenic plant
includes a refrigerator cold box, a warm compressor system, and helium storage,
recovery, and purification systems. The cryogenic distribution system includes
a distribution box, intermediate transfer line, and a tunnel transfer line
consisting of modular bayonet cans which supply and return cryogens to the
cryomodules. A turnaround can is located at the end of the Linac to turnaround
cryogenic flows. This paper describes the layout, design, and current status of
the PIP-II cryogenic system.Comment: 2023 Cryogenic Engineering Conference and International Cryogenic
Materials Conference (CEC/ICMC
The ArDM experiment
The aim of the ArDM project is the development and operation of a one ton
double-phase liquid argon detector for direct Dark Matter searches. The
detector measures both the scintillation light and the ionization charge from
ionizing radiation using two independent readout systems. This paper briefly
describes the detector concept and presents preliminary results from the ArDM
R&D program, including a 3 l prototype developed to test the charge readout
system.Comment: Proceedings of the Epiphany 2010 Conference, to be published in Acta
Physica Polonica
High-Throughput In Vitro, Ex Vivo, and In Vivo Screen of Adeno-Associated Virus Vectors Based on Physical and Functional Transduction
Adeno-associated virus (AAV) vectors are quickly becoming the vectors of choice for therapeutic gene delivery. To date, hundreds of natural isolates and bioengineered variants have been reported. While factors such as high production titer and low immunoreactivity are important to consider, the ability to deliver the genetic payload (physical transduction) and to drive high transgene expression (functional transduction) remains the most important feature when selecting AAV variants for clinical applications. Reporter expression assays are the most commonly used methods for determining vector fitness. However, such approaches are time consuming and become impractical when evaluating a large number of variants. Limited access to primary human tissues or challenging model systems further complicates vector testing. To address this problem, convenient high-throughput methods based on next-generation sequencing (NGS) are being developed. To this end, we built an AAV Testing Kit that allows inherent flexibility in regard to number and type of AAV variants included, and is compatible with in vitro, ex vivo, and in vivo applications. The Testing Kit presented here consists of a mix of 30 known AAVs where each variant encodes a CMV-eGFP cassette and a unique barcode in the 3′-untranslated region of the eGFP gene, allowing NGS-barcode analysis at both the DNA and RNA/cDNA levels. To validate the AAV Testing Kit, individually packaged barcoded variants were mixed at an equal ratio and used to transduce cells/tissues of interest. DNA and RNA/cDNA were extracted and subsequently analyzed by NGS to determine the physical/functional transduction efficiencies. We were able to assess the transduction efficiencies of immortalized cells, primary cells, and induced pluripotent stem cells in vitro, as well as in vivo transduction in naïve mice and a xenograft liver model. Importantly, while our data validated previously reported transduction characteristics of individual capsids, we also identified novel previously unknown tropisms for some AAV variants
First results on light readout from the 1-ton ArDM liquid argon detector for dark matter searches
ArDM-1t is the prototype for a next generation WIMP detector measuring both
the scintillation light and the ionization charge from nuclear recoils in a
1-ton liquid argon target. The goal is to reach a minimum recoil energy of
30\,keVr to detect recoiling nuclei. In this paper we describe the experimental
concept and present results on the light detection system, tested for the first
time in ArDM on the surface at CERN. With a preliminary and incomplete set of
PMTs, the light yield at zero electric field is found to be between 0.3-0.5
phe/keVee depending on the position within the detector volume, confirming our
expectations based on smaller detector setups.Comment: 14 pages, 10 figures, v2 accepted for publication in JINS
Measurement of the scintillation time spectra and pulse-shape discrimination of low-energy beta and nuclear recoils in liquid argon with DEAP-1
The DEAP-1 low-background liquid argon detector was used to measure
scintillation pulse shapes of electron and nuclear recoil events and to
demonstrate the feasibility of pulse-shape discrimination (PSD) down to an
electron-equivalent energy of 20 keV.
In the surface dataset using a triple-coincidence tag we found the fraction
of beta events that are misidentified as nuclear recoils to be (90% C.L.) for energies between 43-86 keVee and for a nuclear recoil
acceptance of at least 90%, with 4% systematic uncertainty on the absolute
energy scale. The discrimination measurement on surface was limited by nuclear
recoils induced by cosmic-ray generated neutrons. This was improved by moving
the detector to the SNOLAB underground laboratory, where the reduced background
rate allowed the same measurement with only a double-coincidence tag.
The combined data set contains events. One of those, in the
underground data set, is in the nuclear-recoil region of interest. Taking into
account the expected background of 0.48 events coming from random pileup, the
resulting upper limit on the electronic recoil contamination is
(90% C.L.) between 44-89 keVee and for a nuclear recoil
acceptance of at least 90%, with 6% systematic uncertainty on the absolute
energy scale.
We developed a general mathematical framework to describe PSD parameter
distributions and used it to build an analytical model of the distributions
observed in DEAP-1. Using this model, we project a misidentification fraction
of approx. for an electron-equivalent energy threshold of 15 keV for
a detector with 8 PE/keVee light yield. This reduction enables a search for
spin-independent scattering of WIMPs from 1000 kg of liquid argon with a
WIMP-nucleon cross-section sensitivity of cm, assuming
negligible contribution from nuclear recoil backgrounds.Comment: Accepted for publication in Astroparticle Physic
Characterization of mixed lymphocyte reaction blocking antibodies (MLR-Bf) in human pregnancy
BACKGROUND: It is known that during normal pregnancy and after immunotherapy blocking antibodies are developed, these antibodies inhibit mixed lymphocyte reaction and are also anti-mitogenic in nature. Mixed lymphocyte reaction blocking antibodies are specific to the husband's lymphocytes. In the present study an attempt has been made to characterize the mixed lymphocyte reaction blocking antibodies in normal pregnancy and in women with recurrent spontaneous abortion after immunotherapy. METHODS: Serum was obtained from women of different gestational windows of pregnancy (Ist, IInd, IIIrd trimesters and post delivery period of normal pregnancy), recurrent spontaneous aborters from pre and post immunization. Healthy (male and females) controls were screened for the presence of mixed lymphocyte reaction blocking antibodies. The standard mixed lymphocyte reaction technique was used to evaluate the inhibitory effect of serum in the mixed lymphocyte reaction. Each serum was tested for cytotoxic antibodies. Immunoglobulin G and its isotypes were isolated according to the standard protocol. RESULTS: In the present study we have observed that there was significant inhibition of proliferation response when immunoglobulin G from different trimesters of pregnancy were added to one way mixed lymphocyte reaction or to phytohemagglutinin activated lymphocyte proliferation assay. Similar pattern was seen when immunoglobulin G isolated from adequately immunized women with recurrent spontaneous abortion was used. It was further confirmed that amongst all the isotypes of immunoglobulin G, only immunoglobulin G-3 was found to be positive for the inhibitory effect. CONCLUSIONS: Present study indicates that mixed lymphocyte reaction blocking antibodies are immunoglobulin G-3 in nature. It is developed during pregnancy and also after immunotherapy in women with recurrent spontaneous abortion who subsequently have the successful pregnancy
Genome-wide BAC-end sequencing of Cucumis melo using two BAC libraries
<p>Abstract</p> <p>Background</p> <p>Although melon (<it>Cucumis melo </it>L.) is an economically important fruit crop, no genome-wide sequence information is openly available at the current time. We therefore sequenced BAC-ends representing a total of 33,024 clones, half of them from a previously described melon BAC library generated with restriction endonucleases and the remainder from a new random-shear BAC library.</p> <p>Results</p> <p>We generated a total of 47,140 high-quality BAC-end sequences (BES), 91.7% of which were paired-BES. Both libraries were assembled independently and then cross-assembled to obtain a final set of 33,372 non-redundant, high-quality sequences. These were grouped into 6,411 contigs (4.5 Mb) and 26,961 non-assembled BES (14.4 Mb), representing ~4.2% of the melon genome. The sequences were used to screen genomic databases, identifying 7,198 simple sequence repeats (corresponding to one microsatellite every 2.6 kb) and 2,484 additional repeats of which 95.9% represented transposable elements. The sequences were also used to screen expressed sequence tag (EST) databases, revealing 11,372 BES that were homologous to ESTs. This suggests that ~30% of the melon genome consists of coding DNA. We observed regions of microsynteny between melon paired-BES and six other dicotyledonous plant genomes.</p> <p>Conclusion</p> <p>The analysis of nearly 50,000 BES from two complementary genomic libraries covered ~4.2% of the melon genome, providing insight into properties such as microsatellite and transposable element distribution, and the percentage of coding DNA. The observed synteny between melon paired-BES and six other plant genomes showed that useful comparative genomic data can be derived through large scale BAC-end sequencing by anchoring a small proportion of the melon genome to other sequenced genomes.</p
- …