36 research outputs found

    Why Are Outcomes Different for Registry Patients Enrolled Prospectively and Retrospectively? Insights from the Global Anticoagulant Registry in the FIELD-Atrial Fibrillation (GARFIELD-AF).

    Get PDF
    Background: Retrospective and prospective observational studies are designed to reflect real-world evidence on clinical practice, but can yield conflicting results. The GARFIELD-AF Registry includes both methods of enrolment and allows analysis of differences in patient characteristics and outcomes that may result. Methods and Results: Patients with atrial fibrillation (AF) and ≥1 risk factor for stroke at diagnosis of AF were recruited either retrospectively (n = 5069) or prospectively (n = 5501) from 19 countries and then followed prospectively. The retrospectively enrolled cohort comprised patients with established AF (for a least 6, and up to 24 months before enrolment), who were identified retrospectively (and baseline and partial follow-up data were collected from the emedical records) and then followed prospectively between 0-18 months (such that the total time of follow-up was 24 months; data collection Dec-2009 and Oct-2010). In the prospectively enrolled cohort, patients with newly diagnosed AF (≤6 weeks after diagnosis) were recruited between Mar-2010 and Oct-2011 and were followed for 24 months after enrolment. Differences between the cohorts were observed in clinical characteristics, including type of AF, stroke prevention strategies, and event rates. More patients in the retrospectively identified cohort received vitamin K antagonists (62.1% vs. 53.2%) and fewer received non-vitamin K oral anticoagulants (1.8% vs . 4.2%). All-cause mortality rates per 100 person-years during the prospective follow-up (starting the first study visit up to 1 year) were significantly lower in the retrospective than prospectively identified cohort (3.04 [95% CI 2.51 to 3.67] vs . 4.05 [95% CI 3.53 to 4.63]; p = 0.016). Conclusions: Interpretations of data from registries that aim to evaluate the characteristics and outcomes of patients with AF must take account of differences in registry design and the impact of recall bias and survivorship bias that is incurred with retrospective enrolment. Clinical Trial Registration: - URL: http://www.clinicaltrials.gov . Unique identifier for GARFIELD-AF (NCT01090362)

    Risk profiles and one-year outcomes of patients with newly diagnosed atrial fibrillation in India: Insights from the GARFIELD-AF Registry.

    Get PDF
    BACKGROUND: The Global Anticoagulant Registry in the FIELD-Atrial Fibrillation (GARFIELD-AF) is an ongoing prospective noninterventional registry, which is providing important information on the baseline characteristics, treatment patterns, and 1-year outcomes in patients with newly diagnosed non-valvular atrial fibrillation (NVAF). This report describes data from Indian patients recruited in this registry. METHODS AND RESULTS: A total of 52,014 patients with newly diagnosed AF were enrolled globally; of these, 1388 patients were recruited from 26 sites within India (2012-2016). In India, the mean age was 65.8 years at diagnosis of NVAF. Hypertension was the most prevalent risk factor for AF, present in 68.5% of patients from India and in 76.3% of patients globally (P < 0.001). Diabetes and coronary artery disease (CAD) were prevalent in 36.2% and 28.1% of patients as compared with global prevalence of 22.2% and 21.6%, respectively (P < 0.001 for both). Antiplatelet therapy was the most common antithrombotic treatment in India. With increasing stroke risk, however, patients were more likely to receive oral anticoagulant therapy [mainly vitamin K antagonist (VKA)], but average international normalized ratio (INR) was lower among Indian patients [median INR value 1.6 (interquartile range {IQR}: 1.3-2.3) versus 2.3 (IQR 1.8-2.8) (P < 0.001)]. Compared with other countries, patients from India had markedly higher rates of all-cause mortality [7.68 per 100 person-years (95% confidence interval 6.32-9.35) vs 4.34 (4.16-4.53), P < 0.0001], while rates of stroke/systemic embolism and major bleeding were lower after 1 year of follow-up. CONCLUSION: Compared to previously published registries from India, the GARFIELD-AF registry describes clinical profiles and outcomes in Indian patients with AF of a different etiology. The registry data show that compared to the rest of the world, Indian AF patients are younger in age and have more diabetes and CAD. Patients with a higher stroke risk are more likely to receive anticoagulation therapy with VKA but are underdosed compared with the global average in the GARFIELD-AF. CLINICAL TRIAL REGISTRATION-URL: http://www.clinicaltrials.gov. Unique identifier: NCT01090362

    Improved risk stratification of patients with atrial fibrillation: an integrated GARFIELD-AF tool for the prediction of mortality, stroke and bleed in patients with and without anticoagulation.

    Get PDF
    OBJECTIVES: To provide an accurate, web-based tool for stratifying patients with atrial fibrillation to facilitate decisions on the potential benefits/risks of anticoagulation, based on mortality, stroke and bleeding risks. DESIGN: The new tool was developed, using stepwise regression, for all and then applied to lower risk patients. C-statistics were compared with CHA2DS2-VASc using 30-fold cross-validation to control for overfitting. External validation was undertaken in an independent dataset, Outcome Registry for Better Informed Treatment of Atrial Fibrillation (ORBIT-AF). PARTICIPANTS: Data from 39 898 patients enrolled in the prospective GARFIELD-AF registry provided the basis for deriving and validating an integrated risk tool to predict stroke risk, mortality and bleeding risk. RESULTS: The discriminatory value of the GARFIELD-AF risk model was superior to CHA2DS2-VASc for patients with or without anticoagulation. C-statistics (95% CI) for all-cause mortality, ischaemic stroke/systemic embolism and haemorrhagic stroke/major bleeding (treated patients) were: 0.77 (0.76 to 0.78), 0.69 (0.67 to 0.71) and 0.66 (0.62 to 0.69), respectively, for the GARFIELD-AF risk models, and 0.66 (0.64-0.67), 0.64 (0.61-0.66) and 0.64 (0.61-0.68), respectively, for CHA2DS2-VASc (or HAS-BLED for bleeding). In very low to low risk patients (CHA2DS2-VASc 0 or 1 (men) and 1 or 2 (women)), the CHA2DS2-VASc and HAS-BLED (for bleeding) scores offered weak discriminatory value for mortality, stroke/systemic embolism and major bleeding. C-statistics for the GARFIELD-AF risk tool were 0.69 (0.64 to 0.75), 0.65 (0.56 to 0.73) and 0.60 (0.47 to 0.73) for each end point, respectively, versus 0.50 (0.45 to 0.55), 0.59 (0.50 to 0.67) and 0.55 (0.53 to 0.56) for CHA2DS2-VASc (or HAS-BLED for bleeding). Upon validation in the ORBIT-AF population, C-statistics showed that the GARFIELD-AF risk tool was effective for predicting 1-year all-cause mortality using the full and simplified model for all-cause mortality: C-statistics 0.75 (0.73 to 0.77) and 0.75 (0.73 to 0.77), respectively, and for predicting for any stroke or systemic embolism over 1 year, C-statistics 0.68 (0.62 to 0.74). CONCLUSIONS: Performance of the GARFIELD-AF risk tool was superior to CHA2DS2-VASc in predicting stroke and mortality and superior to HAS-BLED for bleeding, overall and in lower risk patients. The GARFIELD-AF tool has the potential for incorporation in routine electronic systems, and for the first time, permits simultaneous evaluation of ischaemic stroke, mortality and bleeding risks. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier for GARFIELD-AF (NCT01090362) and for ORBIT-AF (NCT01165710)

    Two-year outcomes of patients with newly diagnosed atrial fibrillation: results from GARFIELD-AF.

    Get PDF
    AIMS: The relationship between outcomes and time after diagnosis for patients with non-valvular atrial fibrillation (NVAF) is poorly defined, especially beyond the first year. METHODS AND RESULTS: GARFIELD-AF is an ongoing, global observational study of adults with newly diagnosed NVAF. Two-year outcomes of 17 162 patients prospectively enrolled in GARFIELD-AF were analysed in light of baseline characteristics, risk profiles for stroke/systemic embolism (SE), and antithrombotic therapy. The mean (standard deviation) age was 69.8 (11.4) years, 43.8% were women, and the mean CHA2DS2-VASc score was 3.3 (1.6); 60.8% of patients were prescribed anticoagulant therapy with/without antiplatelet (AP) therapy, 27.4% AP monotherapy, and 11.8% no antithrombotic therapy. At 2-year follow-up, all-cause mortality, stroke/SE, and major bleeding had occurred at a rate (95% confidence interval) of 3.83 (3.62; 4.05), 1.25 (1.13; 1.38), and 0.70 (0.62; 0.81) per 100 person-years, respectively. Rates for all three major events were highest during the first 4 months. Congestive heart failure, acute coronary syndromes, sudden/unwitnessed death, malignancy, respiratory failure, and infection/sepsis accounted for 65% of all known causes of death and strokes for <10%. Anticoagulant treatment was associated with a 35% lower risk of death. CONCLUSION: The most frequent of the three major outcome measures was death, whose most common causes are not known to be significantly influenced by anticoagulation. This suggests that a more comprehensive approach to the management of NVAF may be needed to improve outcome. This could include, in addition to anticoagulation, interventions targeting modifiable, cause-specific risk factors for death. CLINICAL TRIAL REGISTRATION: http://www.clinicaltrials.gov. Unique identifier: NCT01090362

    High Voltage Electrical Power System Architecture optimized for electrical propulsion and high power payload

    No full text
    International audienceThere is a large design variety of power buses, with voltage levels typically ranging from 28 to 100V. This state-of-art is well adapted to past and current needs in term of power conditioning and disctribution for science and telecommunication satellites. NEvertheless, a short-term need is rising for higher operating voltages, especially for the new electric propulsion systems and high-power payloads. The currently available solutions are to add DC/DC converters inisde echa user equipement to generate all its necessary internal supply lines for the satellite primary power bus. For high power/high voltage loads, this DC/DC stage leads to power dissipation and lowers the overall efficiency of the power chain. A major step forward would be to increase the voltage directly at the level of the primary bus in order to remove some voltage conversion stages leading to lower mass, cost, volume and power dissipation. The work performed within the European Union H2020 project "HV-EPSA" was aimed to study benefits and impact of the implementation of a bus voltage from 300V to 600V, including solar array, solar array drive mechnism, power conditioning and distribution, Hall effect thruster with direct drive topology, battery and harnesses. The main problematic to solve were arcing at high voltage/low pressure (Paschen law), interaction between plasma (natural and from plasmic propulsion) and solar arrays, and distribution function using GaN mosfet. Several test campaigns were performed and the results are presented in the paper.Il existe une grande variété de conception de bus d'alimentation, avec des niveaux de tension allant généralement de 28 à 100 V. Cet état de l'art est bien adapté aux besoins passés et actuels en termes de conditionnement et de distribution de puissance pour les satellites scientifiques et de télécommunications. Néanmoins, le besoin à court terme augmente pour des tensions de fonctionnement plus élevées, en particulier pour les nouveaux systèmes de propulsion électrique et les charges utiles à haute puissance. Les solutions actuellement disponibles consistent à ajouter des convertisseurs DC / DC à l'intérieur de chaque équipement utilisateur afin de générer toutes ses lignes d'alimentation interne nécessaires pour le bus d'alimentation primaire du satellite. Pour les charges haute puissance / haute tension, cet étage DC / DC conduit à une dissipation de puissance et diminue l'efficacité globale de la chaîne de puissance. Un grand pas en avant serait d'augmenter la tension directement au niveau du bus primaire afin de supprimer certains étages de conversion de tension conduisant à une diminution de la masse, du coût, du volume et de la dissipation de puissance. Les travaux réalisés dans le cadre du projet H2020 de l'Union européenne "HV-EPSA" visaient à étudier les avantages et l'impact de la mise en œuvre d'une tension de bus de 300V à 600V, y compris les panneaux solaires, les systèmes d'entraînement de panneaux solaires, le conditionnement et la distribution de l'énergie, le propulseur à effet Hall avec topologie à entraînement direct, batterie et cablâge. Les principaux problèmes à résoudre étaient les arcs à haute tension / basse pression (loi de Paschen), l'interaction entre le plasma (naturel et de propulsion plasmique) et les panneaux solaires, et la fonction de distribution à l'aide du mosfet GaN. Plusieurs campagnes de tests ont été réalisées et les résultats sont présentés dans l'article

    Analysis of Outcomes in Ischemic vs Nonischemic Cardiomyopathy in Patients With Atrial Fibrillation A Report From the GARFIELD-AF Registry

    No full text
    IMPORTANCE Congestive heart failure (CHF) is commonly associated with nonvalvular atrial fibrillation (AF), and their combination may affect treatment strategies and outcomes

    Treatment patterns in anticoagulant therapy in patients with newly diagnosed atrial fibrillation in Belgium: results from the GARFIELD-AF registry

    No full text
    Background: AF, anticoagulation, NOACs, changing patterns of prescription. Methods: We describe baseline data and treatment patterns of patients recruited in Belgium in the Global Anticoagulant Registry in the FIELD-Atrial Fibrillation (GARFIELD-AF). Recruitment began when novel oral anticoagulants (NOACs) were introduced and provides a unique picture of changing treatment patterns over time. 1713 patients with a new (= 2), anticoagulants were used in 84.3%, leaving 15.7% unprotected. In low risk patients (CHA(2)DS(2)-VASc 0-1) anticoagulants were overused (58.7%). Factor Xa inhibitors were used more frequently than direct thrombin inhibitors. Conclusion: Guideline adherence on stroke prevention was higher in Belgium than in the rest of Europe, and increased over time. NOAC use in Belgium was the highest of Europe at the study start, with many countries catching up later. Possible reasons are discussed

    Evolving antithrombotic treatment patterns for patients with newly diagnosed atrial fibrillation

    No full text
    Objective We studied evolving antithrombotic therapy patterns in patients with newly diagnosed non-valvular atrial fibrillation (AF) and >= 1 additional stroke risk factor between 2010 and 2015

    Two-year outcomes of patients with newly diagnosed atrial fibrillation: results from GARFIELD-AF

    No full text
    The relationship between outcomes and time after diagnosis for patients with non-valvular atrial fibrillation (NVAF) is poorly defined, especially beyond the first year

    Predictors of NOAC versus VKA use for stroke prevention in patients with newly diagnosed atrial fibrillation: Results from GARFIELD-AF

    No full text
    Introduction A principal aim of the Global Anticoagulant Registry in the FIELD-Atrial Fibrillation (GARFIELD-AF) was to document changes in treatment practice for patients with newly diagnosed atrial fibrillation during an era when non-vitamin K antagonist oral anticoagulants (NOACs) were becoming more widely adopted. In these analyses, the key factors which determined the choice between NOACs and vitamin K antagonists (VKAs) are explored
    corecore