5,848 research outputs found
Thermal emittance enhancement of graphite-copper composites for high temperature space based radiators
Graphite-copper composites are candidate materials for space based radiators. The thermal emittance of this material, however, is a factor of two lower than the desired emittance for these systems of greater than or equal to 0.85. Arc texturing was investigated as a surface modification technique for enhancing the emittance of the composite. Since the outer surface of the composite is copper, and samples of the composite could not be readily obtained for testing, copper was used for optimization testing. Samples were exposed to various frequencies and currents of arcs during texturing. Emittances near the desired goal were achieved at frequencies less than 500 Hz. Arc current did not appear to play a major role under 15 amps. Particulate carbon was observed on the surface, and was easily removed by vibration and handling. In order to determine morphology adherence, ultrasonic cleaning was used to remove the loosely adherent material. This reduced the emittance significantly. Emittance was found to increase with increasing frequency for the cleaned samples up to 500 Hz. The highest emittance achieved on these samples over the temperature range of interest was 0.5 to 0.6, which is approximately a factor of 25 increase over the untextured copper emittance
Evaluation of the quality and promotion of open learning materials
In the UK, Open Learning has been used in industrial training for at least the last decade. Trainers and Open Learning practitioners have been concerned about the quality of the products and services being delivered. The argument put forward in this thesis is that there is ambiguity amongst industrialists over the meanings of `Open Learning' and `Quality in Open Learning'. For clarity, a new definition of Open Learning is proposed which challenges the traditional learner-centred approach favoured by educationalists. It introduces the concept that there are benefits afforded to the trainer/employer/teacher as well as to the learner. This enables a focussed view of what quality in Open Learning really means. Having discussed these issues, a new quantitative method of evaluating Open Learning is proposed. This is based upon an assessment of the degree of compliance with which products meet Parts 1 & 2 of the Open Learning Code of Practice. The vehicle for these research studies has been a commercial contract commissioned by the Training Agency for the Engineering Industry Training Board (EITB) to examine the quality of Open Learning products supplied to the engineering industry. A major part of this research has been the application of the evaluation technique to a range of 67 Open Learning products (in eight subject areas). The findings were that good quality products can be found right across the price range - so can average and poor quality ones. The study also shows quite convincingly that there are good quality products to be found at less than 50. Finally the majority (24 out of 34) of the good quality products were text based
Dynamic range and mass accuracy of wide-scan direct infusion nanoelectrospray fourier transform ion cyclotron resonance mass spectrometry-based metabolomics increased by the spectral stitching method
Direct infusion nanoelectrospray Fourier transform ion cyclotron resonance mass spectrometry (DI nESI FT-ICR MS)offers high mass accuracy and resolution for analyzing complex metabolite mixtures. High dynamic range across a wide mass range, however, can only be achieved at the expense of mass accuracy, since the large numbers of ions entering the ICR detector induce adverse spacecharge effects. Here we report an optimized strategy for wide-scan DI nESI FT-ICR MS that increases dynamic range but maintains high mass accuracy. It comprises the collection if multiple adjacent selected ion monitoring (SIM) windows that are stitched together using novel algorithms. The final SIM-stitching method, derived from several optimization experiments, comprises 21 adjoining SIM windows each of width m/z 30 (from m/z 70 to 500; adjacent windows overlap by m/z 10) with an automated gain control (AGC) target of 1 105 charges. SIMstitching and wide-scan range (WSR; Thermo Electron)were compared using a defined standard to assess mass accuracy and a liver extract to assess peak count and dynamic range. SIM-stitching decreased the maximum mass error by 1.3- and 4.3-fold, and increased the peak count by 5.3- and 1.8-fold, versus WSR (AGC targets of 1 x 105 and 5 x 105, respectively). SIM-stitching achieved an rms mass error of 0.18 ppm and detected over 3000 peaks in liver extract. This novel approach increases metabolome coverage, has very high mass accuracy, and at 5.5 min/sample is conducive for high- throughput metabolomics
Sequential comparison of tiotropium to high-dose ipratropium in patients with chronic obstructive pulmonary disease in a practice setting
Umair Gauhar, Mark Dransfield, J Allen D CooperPulmonary Section, Birmingham Veterans Affairs Medical Center and Division of Allergy, Pulmonary and Critical Medicine University of Alabama at Birmingham, AL, USAObjective: To determine the effect of changing anticholinergic therapy in patients with COPD from ipratropium to tiotropium on pulmonary function.Methods: We examined records of patients prescribed high-dose ipratropium, who were subsequently converted to tiotropium. Spirometric values were obtained within 2 days of the change in medication and after 56 to 224 days of the switch to tiotropium.Results: 15 subjects were documented to have filled a prescription for ipratropium-containing medications the month prior to the change. Medication compliance over the 6 months prior to the switch in these patients was 72% ± 31% (mean ± SD) for ipratropium compared to 87% ± 14% for tiotropium over the 6-month period after the switch (P = 0.1). FEV1 improved from 1.12 ± 0.39 L at baseline to 1.37 ± 0.49 L after the change to tiotropium (P = 0.01). FVC also improved from 2.45 ± 0.73 L at baseline to 2.72 ± 0.69 L after the change (P = 0.04). Maximal voluntary ventilation was also increased from 39.67 ± 10.7 L/min to 45.13 ± 15.8 L/min (P = 0.045).Conclusions: We conclude that replacing high-dose ipratropium with tiotropium therapy significantly improves pulmonary function in a clinical setting.Keywords: ipratropium, tiotropium, COPD, pulmonary function, exacerbation rat
Recurrent Spontaneous Pneumothorax During Pregnancy; A Case Report
Spontaneous pneumothorax is a rare but potentially life-threatening condition during pregnancy. We discuss a case of recurrent spontaneous pneumothorax during a single pregnancy. The pneumothorax occurred twice during the pregnancy, first in the second trimester and again in the third trimester with both times being managed conservatively. Due to the low prevalence of this condition management guidelines are few. We report our management of recurrent spontaneous pneumothorax during pregnancy to support the literature and current guidelines
Improved fidelity of triggered entangled photons from single quantum dots
We demonstrate the on-demand emission of polarisation-entangled photon pairs
from the biexciton cascade of a single InAs quantum dot embedded in a GaAs/AlAs
planar microcavity. Improvements in the sample design blue shifts the wetting
layer to reduce the contribution of background light in the measurements.
Results presented show that >70% of the detected photon pairs are entangled.
The high fidelity of the (|HxxHx>+|VxxVx>)/2^0.5 state that we determine is
sufficient to satisfy numerous tests for entanglement. The improved quality of
entanglement represents a significant step towards the realisation of a
practical quantum dot source compatible with applications in quantum
information.Comment: 9 pages. Paper is available free of charge at
http://www.iop.org/EJ/abstract/1367-2630/8/2/029/, see also 'A semiconductor
source of triggered entangled photon pairs', R. M. Stevenson et al., Nature
439, 179 (2006
Great Lakes all-weather ice information system
A system is described which utilizes an X-band Side-Looking-Airborne-Radar (SLAR) for determining type, location, and aerial distribution of the ice cover in the Great Lakes and an airborne, S-band, short pulse radar for obtaining ice thickness. The SLAR system is currently mounted aboard a U.S. Coast Guard C-130B aircraft. Digitized SLAR data are relayed in real-time via the NOAA-GOES-1 satellite in geosynchronous orbit to the U.S. Coast Guard Ice Center in Cleveland, Ohio. SLAR images along with hand-drawn interpretative ice charts for various winter shipping areas in the Great Lakes are broadcast to facsimile recorders aboard Great Lakes vessels. The operational aspects of this ice information system are being demonstrated by NASA, U.S. Coast Guard, and NOAA/National Weather Service. Results from the 1974-75 winter season demonstrated the ability of this system to provide all-weather ice information to shippers in a timely manner
A Rare Case of Right Lower Lobe Intralobar Pulmonary Sequestration in an Adult
Pulmonary sequestration is a rare congenital abnormality which is often diagnosed in childhood. There are two types of sequestration which are differentiated by the presence, or lack of pleural lining dividing the aberrant lung tissue from functional lung. Data for the management of this pathology in adults remains scarce. Here we present a case of intralobar pulmonary sequestration in an adult. The management of this patient comprised of surgical treatment involving lobectomy and ligation of the feeding vessel. The patient had an uneventful recovery and final pathology revealed a chronic infection in the sequestration
Life expectancy of persons receiving combination antiretroviral therapy in low-income countries: a cohort analysis from Uganda
Little is known about the effect of combination antiretroviral therapy (cART) on life expectancy in sub-Saharan Africa
The Arizona CDFS Environment Survey (ACES): A Magellan/IMACS Spectroscopic Survey of the Chandra Deep Field South
We present the Arizona CDFS Environment Survey (ACES), a recently-completed
spectroscopic redshift survey of the Chandra Deep Field South (CDFS) conducted
using IMACS on the Magellan-Baade telescope. In total, the survey targeted 7277
unique sources down to a limiting magnitude of R = 24.1, yielding 5080 secure
redshifts across the ~30' x 30' extended CDFS region. The ACES dataset delivers
a significant increase to both the spatial coverage and the sampling density of
the spectroscopic observations in the field. Combined with
previously-published, spectroscopic redshifts, ACES now creates a
highly-complete survey of the galaxy population at R < 23, enabling the local
galaxy density (or environment) on relatively small scales (~1 Mpc) to be
measured at z < 1 in one of the most heavily-studied and data-rich fields in
the sky. Here, we describe the motivation, design, and implementation of the
survey and present a preliminary redshift and environment catalog. In addition,
we utilize the ACES spectroscopic redshift catalog to assess the quality of
photometric redshifts from both the COMBO-17 and MUSYC imaging surveys of the
CDFS.Comment: resubmitted to MNRAS; 12 pages, 12 figures, and 3 tables; updated
redshift catalog available at http://mur.ps.uci.edu/~cooper/ACES
- …