966 research outputs found

    Biochemical parameters of silver catfish (Rhamdia quelen) after transport with eugenol or essential oil of Lippia alba added to the water

    Get PDF
    The transport of live fish is a routine practice in aquaculture and constitutes a considerable source of stress to the animals. The addition of anesthetic to the water used for fish transport can prevent or mitigate the deleterious effects of transport stress. This study investigated the effects of the addition of eugenol (EUG) (1.5 or 3.0 mu L L-1) and essential oil of Lippia alba (EOL) (10 or 20 mu L L-1) on metabolic parameters (glycogen, lactate and total protein levels) in liver and muscle, acetylcholinesterase activity (AChE) in muscle and brain, and the levels of protein carbonyl (PC), thiobarbituric acid reactive substances (TBARS) and nonprotein thiol groups (NPSH) and activity of glutathione-S-transferase in the liver of silver catfish (Rhamdia quelen; Quoy and Gaimard, 1824) transported for four hours in plastic bags (loading density of 169.2 g L-1). The addition of various concentrations of EUG (1.5 or 3.0 mu L L-1) and EOL (10 or 20 mu L L-1) to the transport water is advisable for the transportation of silver catfish, since both concentrations of these substances increased the levels of NPSH antioxidant and decreased the TBARS levels in the liver. In addition, the lower liver levels of glycogen and lactate in these groups and lower AChE activity in the brain (EOL 10 or 20 mu L L-1) compared to the control group indicate that the energetic metabolism and neurotransmission were lower after administration of anesthetics, contributing to the maintenance of homeostasis and sedation status.Fundacao de Amparo a Pesquisa do Estado do Rio Grande do Sul (FAPERGS/PRONEX) [10/0016-8]; Conselho Nacional de Pesquisa e Desenvolvimento Cientifico (CNPq) [470964/2009-0]; Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior (CAPES); CNPqinfo:eu-repo/semantics/publishedVersio

    Black Hole Spin via Continuum Fitting and the Role of Spin in Powering Transient Jets

    Full text link
    The spins of ten stellar black holes have been measured using the continuum-fitting method. These black holes are located in two distinct classes of X-ray binary systems, one that is persistently X-ray bright and another that is transient. Both the persistent and transient black holes remain for long periods in a state where their spectra are dominated by a thermal accretion disk component. The spin of a black hole of known mass and distance can be measured by fitting this thermal continuum spectrum to the thin-disk model of Novikov and Thorne; the key fit parameter is the radius of the inner edge of the black hole's accretion disk. Strong observational and theoretical evidence links the inner-disk radius to the radius of the innermost stable circular orbit, which is trivially related to the dimensionless spin parameter a_* of the black hole (|a_*| < 1). The ten spins that have so far been measured by this continuum-fitting method range widely from a_* \approx 0 to a_* > 0.95. The robustness of the method is demonstrated by the dozens or hundreds of independent and consistent measurements of spin that have been obtained for several black holes, and through careful consideration of many sources of systematic error. Among the results discussed is a dichotomy between the transient and persistent black holes; the latter have higher spins and larger masses. Also discussed is recently discovered evidence in the transient sources for a correlation between the power of ballistic jets and black hole spin.Comment: 30 pages. Accepted for publication in Space Science Reviews. Also to appear in hard cover in the Space Sciences Series of ISSI "The Physics of Accretion onto Black Holes" (Springer Publisher). Changes to Sections 5.2, 6.1 and 7.4. Section 7.4 responds to Russell et al. 2013 (MNRAS, 431, 405) who find no evidence for a correlation between the power of ballistic jets and black hole spi

    Conservation physiology across scales: Insights from the marine realm

    Get PDF
    As the field of conservation physiology develops and becomes increasingly integrated with ecolog

    Characterisation of the muon beams for the Muon Ionisation Cooling Experiment

    Get PDF
    A novel single-particle technique to measure emittance has been developed and used to characterise seventeen different muon beams for the Muon Ionisation Cooling Experiment (MICE). The muon beams, whose mean momenta vary from 171 to 281 MeV/c, have emittances of approximately 1.2–2.3 π mm-rad horizontally and 0.6–1.0 π mm-rad vertically, a horizontal dispersion of 90–190 mm and momentum spreads of about 25 MeV/c. There is reasonable agreement between the measured parameters of the beams and the results of simulations. The beams are found to meet the requirements of MICE

    A measurement of the tau mass and the first CPT test with tau leptons

    Full text link
    We measure the mass of the tau lepton to be 1775.1+-1.6(stat)+-1.0(syst.) MeV using tau pairs from Z0 decays. To test CPT invariance we compare the masses of the positively and negatively charged tau leptons. The relative mass difference is found to be smaller than 3.0 10^-3 at the 90% confidence level.Comment: 10 pages, 4 figures, Submitted to Phys. Letts.

    Prognostic models for identifying risk of poor outcome in people with acute ankle sprains: the SPRAINED development and external validation study

    Get PDF
    BACKGROUND: Ankle sprains are very common injuries. Although recovery can occur within weeks, around one-third of patients have longer-term problems. OBJECTIVES: To develop and externally validate a prognostic model for identifying people at increased risk of poor outcome after an acute ankle sprain. DESIGN: Development of a prognostic model in a clinical trial cohort data set and external validation in a prospective cohort study. SETTING: Emergency departments (EDs) in the UK. PARTICIPANTS: Adults with an acute ankle sprain (within 7 days of injury). SAMPLE SIZE: There were 584 clinical trial participants in the development data set and 682 recruited for the external validation study. PREDICTORS: Candidate predictor variables were chosen based on availability in the clinical data set, clinical consensus, face validity, a systematic review of the literature, data quality and plausibility of predictiveness of the outcomes. MAIN OUTCOME MEASURES: Models were developed to predict two composite outcomes representing poor outcome. Outcome 1 was the presence of at least one of the following symptoms at 9 months after injury: persistent pain, functional difficulty or lack of confidence. Outcome 2 included the same symptoms as outcome 1, with the addition of recurrence of injury. Rates of poor outcome in the external data set were lower than in the development data set, 7% versus 20% for outcome 1 and 16% versus 24% for outcome 2. ANALYSIS: Multiple imputation was used to handle missing data. Logistic regression models, together with multivariable fractional polynomials, were used to select variables and identify transformations of continuous predictors that best predicted the outcome based on a nominal alpha of 0.157, chosen to minimise overfitting. Predictive accuracy was evaluated by assessing model discrimination (c-statistic) and calibration (flexible calibration plot). RESULTS: (1) Performance of the prognostic models in development data set - the combined c-statistic for the outcome 1 model across the 50 imputed data sets was 0.74 [95% confidence interval (CI) 0.70 to 0.79], with good model calibration across the imputed data sets. The combined c-statistic for the outcome 2 model across the 50 imputed data sets was 0.70 (95% CI 0.65 to 0.74), with good model calibration across the imputed data sets. Updating these models, which used baseline data collected at the ED, with an additional variable at 4 weeks post injury (pain when bearing weight on the ankle) improved the discriminatory ability (c-statistic 0.77, 95% CI 0.73 to 0.82, for outcome 1 and 0.75, 95% CI 0.71 to 0.80, for outcome 2) and calibration of both models. (2) Performance of the models in the external data set - the combined c-statistic for the outcome 1 model across the 50 imputed data sets was 0.73 (95% CI 0.66 to 0.79), with a calibration plot intercept of -0.91 (95% CI -0.98 to 0.44) and slope of 1.13 (95% CI 0.76 to 1.50). The combined c-statistic for the outcome 2 model across the 50 imputed data sets was 0.63 (95% CI 0.58 to 0.69), with a calibration plot intercept of -0.25 (95% CI -0.27 to 0.11) and slope of 1.03 (95% CI 0.65 to 1.42). The updated models with the additional pain variable at 4 weeks had improved discriminatory ability over the baseline models but not better calibration. CONCLUSIONS: The SPRAINED (Synthesising a clinical Prognostic Rule for Ankle Injuries in the Emergency Department) prognostic models performed reasonably well, and showed benefit compared with not using any model; therefore, the models may assist clinical decision-making when managing and advising ankle sprain patients in the ED setting. The models use predictors that are simple to obtain. LIMITATIONS: The data used were from a randomised controlled trial and so were not originally intended to fulfil the aim of developing prognostic models. However, the data set was the best available, including data on the symptoms and clinical events of interest. FUTURE WORK: Further model refinement, including recalibration or identifying additional predictors, may be required. The effect of implementing and using either model in clinical practice, in terms of acceptability and uptake by clinicians and on patient outcomes, should be investigated. TRIAL REGISTRATION: Current Controlled Trials ISRCTN12726986. FUNDING: This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 22, No. 64. See the NIHR Journals Library website for further project information. Funding was also recieved from the NIHR Collaboration for Leadership in Applied Health Research, Care Oxford at Oxford Health NHS Foundation Trust, NIHR Biomedical Research Centre, Oxford, and the NIHR Fellowship programme

    Measurement of the B0 Lifetime and Oscillation Frequency using B0->D*+l-v decays

    Full text link
    The lifetime and oscillation frequency of the B0 meson has been measured using B0->D*+l-v decays recorded on the Z0 peak with the OPAL detector at LEP. The D*+ -> D0pi+ decays were reconstructed using an inclusive technique and the production flavour of the B0 mesons was determined using a combination of tags from the rest of the event. The results t_B0 = 1.541 +- 0.028 +- 0.023 ps, Dm_d = 0.497 +- 0.024 +- 0.025 ps-1 were obtained, where in each case the first error is statistical and the second systematic.Comment: 17 pages, 4 figures, submitted to Phys. Lett.

    First Measurement of Z/gamma* Production in Compton Scattering of Quasi-real Photons

    Full text link
    We report the first observation of Z/gamma* production in Compton scattering of quasi-real photons. This is a subprocess of the reaction e+e- to e+e-Z/gamma*, where one of the final state electrons is undetected. Approximately 55 pb-1 of data collected in the year 1997 at an e+e- centre-of-mass energy of 183 GeV with the OPAL detector at LEP have been analysed. The Z/gamma* from Compton scattering has been detected in the hadronic decay channel. Within well defined kinematic bounds, we measure the product of cross-section and Z/gamma* branching ratio to hadrons to be (0.9+-0.3+-0.1) pb for events with a hadronic mass larger than 60 GeV, dominated by (e)eZ production. In the hadronic mass region between 5 GeV and 60 GeV, dominated by (e)egamma* production, this product is found to be (4.1+-1.6+-0.6) pb. Our results agree with the predictions of two Monte Carlo event generators, grc4f and PYTHIA.Comment: 18 pages, LaTeX, 5 eps figures included, submitted to Physics Letters
    • …
    corecore