106 research outputs found

    Background 18F-FDG uptake in positron emission mammography (PEM): Correlation with mammographic density and background parenchymal enhancement in breast MRI

    Get PDF
    AbstractWe aimed to determine whether background 18F-FDG uptake in positron emission mammography (PEM) was related to mammographic density or background parenchymal enhancement in breast MRI.MethodsWe studied a total of 52 patients (mean age, 50.9 years, 26 premenopausal, 26 postmenopausal) with newly diagnosed breast cancer who underwent 18F-FDG PEM (positron emission mammography), conventional mammography and breast MRI. The background mean 18F-FDG uptake value on PEM was obtained by drawing a user-defined region of interest (ROI) in a normal area of the contralateral breast. We reviewed the mammography retrospectively for overall breast density of contralateral breast according to the four-point scale (grade 1–4) of the Breast Imaging Reporting and Data System (BI-RADS) classification. The background parenchymal enhancement of breast MRI was classified as minimal, mild, moderate, or marked. All imaging findings were interpreted by two readers in consensus without knowledge of image findings of other modalities.ResultsMultiple linear regression analysis revealed a significant correlation between background 18F-FDG uptake on PEM and mammographic density after adjustment for age and menopausal status (P<0.01), but not between background 18F-FDG uptake on PEM and background parenchymal enhancement on MRI.ConclusionBackground 18F-FDG uptake on PEM significantly increases as mammographic density increases. Background parenchymal enhancement in breast MRI was not an independent predictor of the background 18F-FDG uptake on PEM unlike mammographic density

    Does Ultrasound-Guided Directional Vacuum-Assisted Removal Help Eliminate Abnormal Nipple Discharge in Patients with Benign Intraductal Single Mass?

    Get PDF
    Objective: To evaluate whether the removal of an intraductal mass using an ultrasound (US)-guided directional vacuum-assisted device can eliminate symptoms in patients presenting with abnormal nipple discharge. Materials and Methods: Between March 2004 and October 2006, 36 patients who presented with abnormal nipple discharge, underwent US-guided, 11-gauge vacuum-assisted biopsy for a benign intraductal single mass on US. The ability of the procedure to eliminate nipple discharge was evaluated by physical examination during follow-up US. Lesion characteristics, biopsy variables, and histologic features were analyzed to identify factors affecting symptom resolution. Results: Of the 36 lesions, 25 (69%) were intraductal papillomas, 10 (28%) were fibrocystic changes, and one (3%) was a fibroadenoma. The nipple discharge disappeared in 69% (25 of 36) of the women at a mean follow-up time of 25 months (range 12-42 month). There was no difference in the lesion characteristics, biopsy variables, and the histologic features between groups that eliminated the symptom compared those with persistent nipple discharge. Conclusion: US-guided directional vacuum-assisted removal of an intraductal mass appears to eliminate nipple discharge in only 69% of patients and thus, it should not be considered as an alternative to surgical excision.This study was supported by a grant (A070001) of the Korea Healthcare Technology R&D Project, Ministry for Realm, Welfare & Family Affairs, and the Republic of Korea

    Underestimation of atypical ductal hyperplasia at sonographically guided core biopsy of the breast

    Get PDF
    OBJECTIVE: The purpose of this study was to determine the rate of underestimation of atypical ductal hyperplasia (ADH) at sonographically guided core biopsy of the breast and to identify the factors involved. MATERIALS AND METHODS: We retrospectively reviewed 3,563 lesions con secutively evaluated with sonographically guided core biopsy between January 2002 and June 2006. Histologic analysis yielded ADH in 60 of the 3,563 lesions (1.7%). The rate of underestimation of ADH was determined by dividing the number of lesions that proved to be carcinoma at surgical excision by 44, the total number of lesions evaluated with excisional biopsy. Clinical, sonographic, and core biopsy features were analyzed to identify factors that affect the rate of underestimation of ADH. RESULTS: The rate of underestimation of ADH was found to be 48% (21 of 44 lesions). Underestimation of ADH was significantly less frequent for lesions evaluated with 11-gauge vacuum-assisted biopsy than for lesions evaluated with 14-gauge automated gun biopsy (22% [four of 18 lesions] vs 65% [17 of 26 lesions], p = 0.012). The other clinical, sonographic, and biopsy features examined did not affect the rate of underestimation of ADH. CONCLUSION: For sonographically guided core biopsy of the breast, the rate of underestimation of ADH was 48%. This rate was lower for lesions evaluated with 11-gauge vacuum-assisted biopsy (22%) than for those evaluated with 14-gauge automated gun biopsy (65%). This finding was particularly true of smaller lesions (< or = 2.0 cm) and for lesions of the mass-only type.Supported by grant A062260 from the Innovative Research Institute for Cell Therapy, Republic of Korea

    Planalto barrosão

    Get PDF
    O concelho de Montalegre, situado no planalto Barrosão, é uma das regiões mais remotas e isoladas de Portugal Continental. É um território com baixa densidade populacional, em que cerca de um quarto da superfície do concelho se situa dentro do Parque Nacional da Peneda Gerês, a elevada altitude. É sobre este circunstancialismo geográfico, que permitiu preservar uma ruralidade vincada, que recai a representação fotográfica de paisagem do Planalto do Barroso. É uma representação da paisagem como uma construção cultural e pretende questionar as fronteiras de uma paisagem protegida e como se relaciona com questões de identidade e património.Montalegre, in the Northeast of Portugal, is one of the most remote and isolated areas of the country. The region is an important part of a National Park, the Peneda Geres, located at high altitude and with a very low level of human occupation. This geographic aspect, that led to the preservation and observation of a strong rurality, allowed a photographic representation of the landscape in Barroso´s Plateaus. It’s a photographic representation of the landscape as a cultural construction, questioning the frontiers of a protected landscape and how it relates to heritage and identity

    Reproducibility of Computer-Aided Detection Marks in Digital Mammography

    Get PDF
    OBJECTIVE: To evaluate the performance and reproducibility of a computeraided detection (CAD) system in mediolateral oblique (MLO) digital mammograms taken serially, without release of breast compression. MATERIALS AND METHODS: A CAD system was applied preoperatively to the fullfield digital mammograms of two MLO views taken without release of breast compression in 82 patients (age range: 33-83 years; mean age: 49 years) with previously diagnosed breast cancers. The total number of visible lesion components in 82 patients was 101: 66 masses and 35 microcalcifications. We analyzed the sensitivity and reproducibility of the CAD marks. RESULTS: The sensitivity of the CAD system for first MLO views was 71% (47/66) for masses and 80% (28/35) for microcalcifications. The sensitivity of the CAD system for second MLO views was 68% (45/66) for masses and 17% (6/35) for microcalcifications. In 84 ipsilateral serial MLO image sets (two patients had bilateral cancers), identical images, regardless of the existence of CAD marks, were obtained for 35% (29/84) and identical images with CAD marks were obtained for 29% (23/78). Identical images, regardless of the existence of CAD marks, for contralateral MLO images were 65% (52/80) and identical images with CAD marks were obtained for 28% (11/39). The reproducibility of CAD marks for the true positive masses in serial MLO views was 84% (42/50) and that for the true positive microcalcifications was 0% (0/34). CONCLUSION: The CAD system in digital mammograms showed a high sensitivity for detecting masses and microcalcifications. However, reproducibility of microcalcification marks was very low in MLO views taken serially without release of breast compression. Minute positional change and patient movement can alter the images and result in a significant effect on the algorithm utilized by the CAD for detecting microcalcifications

    Correlation between High Resolution Dynamic MR Features and Prognostic Factors in Breast Cancer

    Get PDF
    OBJECTIVE: To correlate high resolution dynamic MR features with prognostic factors in breast cancer. MATERIALS AND METHODS: One hundred and ninety-four women with invasive ductal carcinomas underwent dynamic MR imaging using T1-weighted three-dimensional fast low-angle shot (3D-FLASH) sequence within two weeks prior to surgery. Morphological and kinetic MR features were determined based on the breast imaging and reporting data system (BI-RADS) MR imaging lexicon. Histological specimens were analyzed for tumor size, axillary lymph node status, histological grade, expression of estrogen receptor (ER), expression of progesterone receptor (PR), and expression of p53, c-erbB-2, and Ki-67. Correlations between the MR features and prognostic factors were determined using the Pearson chi(2) test, linear-by-linear association, and logistic regression analysis. RESULTS: By multivariate analysis, a spiculated margin was a significant, independent predictor of a lower histological grade (p < 0.001), and lower expression of Ki-67 (p = 0.007). Rim enhancement was significant, independent predictor of a higher histological grade (p < 0.001), negative expression of ER (p = 0.001), negative expression of PR (p < 0.001) and a larger tumor size (p = 0.006). A washout curve may predict a higher level of Ki-67 (p = 0.05). Most of the parameters of the initial enhancement phase cannot predict the status of the prognostic factors. Only the enhancement ratio may predict a larger tumor size (p = 0.05). CONCLUSION: Of the BI-RADS-MR features, a spiculated margin may predict favorable prognosis, whereas rim enhancement or washout may predict unfavorable prognosis of breast cancer

    Sonographically-Guided 14-Gauge Core Needle Biopsy for Papillary Lesions of the Breast

    Get PDF
    OBJECTIVE: We wanted to assess the need for surgical excising papillary lesions of the breast that were diagnosed upon sonographically guided 14-gauge core needle biopsy. MATERIALS AND METHODS: Sixty-nine women (age range: 25-74 years, mean age: 51.7 years) with 69 papillary lesions (4.9%) were diagnosed and followed after performing sonographically guided 14-gauge core needle biopsies. Surgical excision was performed for 44 (64%) of 69 papillary lesions, and 25 lesions were followed with imaging studies (range: 6-46 months, mean: 17.9 months). The histologic findings upon core biopsy were compared with the surgical, imaging and follow-up findings. RESULTS: Core needle biopsies of 69 lesions yielded tissue that was classified as benign for 43 lesions, atypical for 18 lesions and malignant for eight lesions. Of the 43 lesions that yielded benign papilloma upon core needle biopsy, one had intraductal papillary carcinoma found upon surgery. An immediate surgical biopsy was recommended for this lesion because of the imaging-histologic discordance. No additional carcinoma was found during the imaging follow-up. Surgical excision was performed for 17 atypical papillary lesions, and this revealed intraductal (n = 6) or invasive (n = 2) papillary carcinoma in 8 (47%) lesions. Of the seven intraductal papillary carcinomas, surgery revealed invasive papillary carcinoma in one (14%). CONCLUSION: Our results suggest that papillary lesions of the breast that are diagnosed as benign upon sonographically guided 14-gauge core needle biopsy can be followed when the results are concordant with the imaging findings
    corecore