579 research outputs found

    The System Simulation with Optimization Mechanism for Option Pricing

    Get PDF
    The Monte Carlo approach is a valuable and flexible computational tool in modern finance, and is one of numerical procedures used for solving option valuation problems. In recent years the complexity of numerical computation in financial theory and practice has increased and require more computational power and efficiency. Monte Carlo simulation is one of the numerical computation methods used for financial engineering problems. The drawback of Monte Carlo simulation is computationally intensive and time-consuming. In attempt to tackle such an issue, many recent applications of the Monte Carlo approach to security pricing problems have been discussed with emphasis on improvements in efficiency. This paper presents a novel approach combining system simulation with GA-based optimization to pricing options. This paper shows how the proposed approach can significantly resolve the option pricing problem

    Use of new radiochromic devices for peripheral dose measurement: potential in-vivo dosimetry application

    Get PDF
    The authors have studied the feasibility of using three new high-sensitivity radiochromic devices in measuring the doses to peripheral points outside the primary megavoltage photon beams. The three devices were GAFCHROMIC® EBT film, prototype Low Dose (LD) Film, and prototype LD Card. The authors performed point dosimetry using these three devices in water-equivalent solid phantoms at x = 3,5,8,10, and 15 cm from the edge of 6 MV and 15 MV photon beams of 10x10 cm2, and at depths of 0, 0.5 cm, and depth of maximum dose. A full sheet of EBT film was exposed with 5000 MU. The prototype LD film pieces were 1.5x2 cm2 in size. Some LD films were provided in the form of a card in 1.8x5 cm2 holding an active film in 1.8x2 cm2. These are referred to as “LD dosimeter cards”. The small LD films and cards were exposed with 500 MU. For each scanned film, a 6 mm circular area centered at the measurement point was sampled and the mean pixel value was obtained. The calibration curves were established from the calibration data for each combination of film/cards and densitometer/scanner. The doses at the peripheral points determined from the films were compared with those obtained using ion chamber at respective locations in a water phantom and general agreements were found. It is feasible to accurately measure peripheral doses of megavoltage photon beams using the new high-sensitivity radiochromic devices. This near real-time and inexpensive method can be applied in a clinical setting for dose measurements to critical organs and sensitive patient implant devices

    Outcomes in Neonates with Pulmonary Atresia and Intact Ventricular Septum Underwent Pulmonary Valvulotomy and Valvuloplasty Using a Flexible 2-French Radiofrequency Catheter

    Get PDF
    Purpose : Outcomes in 6 neonates with pulmonary atresia and intact ventricular septum (PAIVS) Undergoing radiofrequency pulmonary valvulotomy and valvuloplasty (RPVV) were reported to identify the factors favorable for RPVV as the treatment of choice. Materials and Methods: From May 2000 to January 2008, 6 patients with PAWS were included in this retrospective study. They were aged I day to 90 days old. Study modalities included review of recordings of presentations and profiles of chest radiography, electrocardiography, echocardiography, and cardiac catheterization with angiography. Hemodynamic profiles from the echocardiography and the cardiac catheterization were analyzed. Results: Echocardiography showed severe tricuspid regurgitation, membranous atresia of the pulmonary valve, intact ventricular septum, patent ductus arteriosus, and hypoplastic right ventricle in 6 patients. The pulmonary valve annulus were 4.2 to 6.9 mm in diameters, and those of the tricuspid valve were 7.1 to 10.1 mm. Elevated serum level of cardiac enzymes were found in 1 patient with ventriculocoronary communication (VCC). At cardiac catheterization, the ratio of systolic pressure of the right ventricle to that of the left ventricle ranged from 1.43 to 2.33 before RPVV, and from 0.54 to 1.15 after RPVV ((p=0. 027). The pressure gradients ranged from 76 to 136 mmHg before RPVV, and from 15 to 39 mmHg after RPVV (p=0.028). The echocardiographic gradients ranged from 16 to 32 mmHg within 24 hours after RPVV, and from 15 to 50 mmHg at the follow-ups. Conclusion: RPVV can be a treatment of choice for neonates with PAIVS, if there is patent infundibulum, no right-ventricular dependent coronary circulation, and adequate tricuspid valve and pulmonary valve

    New Plasma Separation Glucose Oxidase-based Glucometer in Monitoring of Blood With Different PO2 Levels

    Get PDF
    BackgroundThe PalmLab glucometer is a newly designed plasma separation glucose oxidase (GO)-based glucometer. Past studies have shown that the accuracy of GO-based glucometers is compromised when measurements are taken in patients with high PO2 levels. We performed a two-arm study comparing the fitness of the PalmLab blood glucometer with that of a standard glucose analyzer in monitoring blood glucose levels in pediatric patients, especially when arterial partial pressure of oxygen (PO2) was high.MethodsIn the first arm of the study, arterial blood samples from pediatric patients were measured by the PalmLab blood glucometer and the YSI 2302 Plus Glucose/Lactate analyzer. In the second arm of the study, venous blood samples from adult volunteers were spiked with glucose water to prepare three different levels of glucose (65, 150, and 300mg/dL) and then oxygenated to six levels of PO2 (range, 40–400mmHg). The biases of the PalmLab glucometer were calculated.ResultsA total of 162 samples were collected in the first arm of the study. Results of linear regression showed that the coefficient of determination (R2) between PalmLab glucometer and standard glucose analyzer was 0.9864. Error grid analysis revealed that all the results were within Zone A (clinically accurate estimate zone). The biases between the two systems were low at different PO2 levels. In the second arm of the study, the results were also unaffected by changes in PO2.ConclusionThe PalmLab glucometer provides accurate results in samples with high PO2 and is suitable for measuring arterial glucose levels in pediatric patients

    Effect of bis(hydroxymethyl) alkanoate curcuminoid derivative MTH-3 on cell cycle arrest, apoptotic and autophagic pathway in triple-negative breast adenocarcinoma MDA-MB-231 cells: An in vitro study

    Get PDF
    Curcumin has been shown to exert potential antitumor activity in vitro and in vivo involved in multiple signaling pathways. However, the application of curcumin is still limited because of its poor hydrophilicity and low bio-availability. In the present study, we investigated the therapeutic effects of a novel and water soluble bis(hydroxymethyl) alkanoate curcuminoid derivative, MTH-3, on human breast adenocarcinoma MDA-MB-231 cells. This study investigated the effect of MTH-3 on cell viability, cell cycle and induction of autophagy and apoptosis in MDA-MB-231 cells. After 24-h treatment with MTH-3, a concentration-dependent decrease in MDA-MB-231 cell viability was observed, and the IC50 value was 5.37±1.22 μM. MTH-3 significantly triggered G2/M phase arrest and apoptosis in MDA-MB-231 cells. Within a 24-h treatment, MTH-3 decreased the CDK1 activity by decreasing CDK1 and cyclin B1 protein levels. MTH-3-induced apoptosis was further confirmed by morphological assessment and Annexin V/PI staining assay. Induction of apoptosis caused by MTH-3 was accompanied by an apparent increase of DR3, DR5 and FADD and, as well as a marked decrease of Bcl-2 and Bcl-xL protein expression. MTH-3 also decreased the protein levels of Ero1, PDI, PERK and calnexin, as well as increased the expression of IRE1α, CHOP and Bip that consequently led to ER stress and MDA-MB-231 cell apoptosis. In addition, MTH-3-treated cells were involved in the autophagic process and cleavage of LC3B was observed. MTH-3 enhanced the protein levels of LC3B, Atg5, Atg7, Atg12, p62 and Beclin-1 in MDA-MB-231 cells. Finally, DNA microarray was carried out to investigate the level changes of gene expression modulated by MTH-3 in MDA-MB-231 cells. Taken together, our results suggest that MTH-3 might be a novel therapeutic agent for the treatment of triple-negative breast cancer in the near future
    corecore