1,823 research outputs found
Bacteriocin production by spray-dried lactic acid bacteria
Cell survival and antagonistic activity against Listeria innocua, Listeria monocytogenes and Staphylococcus aureus were investigated after spray-drying three bacteriocin-producing strains of lactic acid bacteria: Carnobacterium divergens, Lactobacillus salivarius and Lactobacillus sakei
Bacterial biofilms, antibiotic resistance and healthcare-associated infections: a dangerous connection.
Effectiveness of XP-endo finisher in the reduction of bacterial load in oval-shaped root canals
This study investigated the effectiveness of XP-Endo Finisher (XPF) associated with XP-Endo Shaper (XPS) or Reciproc Blue (RB) files in reducing bacterial load in oval-shaped root canals (RC) during chemomechanical preparation (CMP) using 0.9% saline solution (NaCl) or 2.5% sodium hypochlorite (NaOCl). Eighty mandibular incisors with single oval-shaped RC were contaminated with Enterococcus faecalis. The teeth were randomly assigned to eight experimental groups (n = 10) according to the CMP, as follows: G1: XPS, G2: XPS + XPF, G3: RB, and G4: RB + XPF. CMP was performed with NaCl or NaOCl. The reduction of bacterial load was assessed by colony-forming unit count before (S1) and after (S2) CMP. Data normality was verified by using Shapiro-Wilk test. ANOVA, Tukey's test, and Bonferroni post-hoc test were used at a 5% significance level. Culturable bacteria were present in all S1 samples (p>0.05). All instrumentation techniques were effective in reducing bacterial load, irrespective of the irrigating solution (p < 0.05). With the use of NaCl, RB was more effective than XPS (p = 0.035). With the use of NaOCl, XPS and RB presented similar effectiveness (p = 0.779). XPF enhanced the bacterial reduction of both systems tested (p < 0.05). The use of NaOCl improved the CMP, irrespective of the instrumentation technique used (p < 0.05). In conclusion, XPS and RB files are effective in reducing bacterial levels in oval-shaped RC. The use of XPF as a method of agitation of the irrigating solution improved the cleaning efficiency of both file systems tested. Mechanical preparation performed with saline solution decreased culturable bacteria from the root canal, but antimicrobial substances such as NaOCl should be used to achieve a significantly better disinfection33CONSELHO NACIONAL DE DESENVOLVIMENTO CIENTÍFICO E TECNOLÓGICO - CNPQCOORDENAÇÃO DE APERFEIÇOAMENTO DE PESSOAL DE NÍVEL SUPERIOR - CAPESFUNDAÇÃO DE AMPARO À PESQUISA DO ESTADO DE SÃO PAULO - FAPESP308162/2014-5não tem2015/23479-
Recommended from our members
Silicon Powder-Based Wafers for Low-Cost Photovoltaics: Laser Treatments and Nanowire Etching
In this study, laser-treated polycrystalline Si (pc-Si) wafers, fabricated by wire sawing of hot-pressed ingots sintered from Si powder, have been investigated. As-cut wafers and those with high-quality thin Si layers deposited on top of them by e-beam have been subjected to laser irradiation to clarify typical trends of structural modifications caused by laser treatments. Moreover, possibility to use laser-treated Si powder-based substrates for fabrication of advanced Si structures has been analysed. It is established that (i) Si powder-based wafers with thicknesses 180 μm can be fully (from the front to back side) or partly (subsurface region) remelted by a diode laser and grain sizes in laser-treated regions can be increased; (ii) a high-quality top layer can be fabricated by crystallization of an additional a-Si layer deposited by e-beam evaporation on top of the pc-Si; and (iii) silicon nanowires can be formed by metal-assisted wet chemical etching (MAWCE) of polished Si powder-based wafers and as-cut wafers irradiated with medium laser power, while a surface texturing on the as-cut pc-Si wafers occur, and no nanowires can form in the region subject to a liquid phase crystallization (LPC) caused by high-power laser treatments
Invariant Natural Killer T-cells and their subtypes may play a role in the pathogenesis of endometriosis
Objective: To evaluate the frequencies of iNKT cells and their subsets in patients with deep endometriosis.
Methods: A case-control study was conducted between 2013 and 2015, with 73 patients distributed into two groups: 47 women with a histological diagnosis of endometriosis and 26 controls. Peripheral blood, endometriosis lesions, and healthy peritoneal samples were collected on the day of surgery to determine the frequencies of iNKT cells and subtypes via flow cytometry analysis.
Results: The authors observed a lower number of iNKT (p = 0.01) and Double-Negative (DN) iNKT cells (p = 0.02) in the blood of patients with endometriosis than in the control group. The number of DN iNKT IL-17+ cells in the secretory phase was lower in the endometriosis group (p = 0.049). There was an increase in the secretion of IL-17 by CD4+ iNKT cells in the blood of patients with endometriosis and severe dysmenorrhea (p = 0.038), and severe acyclic pelvic pain (p = 0.048). Patients with severe dysmenorrhea also had a decreased number of CD4+ CCR7+ cells (p = 0.022).
Conclusion: The decreased number of total iNKT and DN iNKT cells in patients with endometriosis suggests that iNKT cells play a role in the pathogenesis of endometriosis and can be used to develop new diagnostic and therapeutic agents
Chaotic Diffusion on Periodic Orbits: The Perturbed Arnol'd Cat Map
Chaotic diffusion on periodic orbits (POs) is studied for the perturbed
Arnol'd cat map on a cylinder, in a range of perturbation parameters
corresponding to an extended structural-stability regime of the system on the
torus. The diffusion coefficient is calculated using the following PO formulas:
(a) The curvature expansion of the Ruelle zeta function. (b) The average of the
PO winding-number squared, , weighted by a stability factor. (c) The
uniform (nonweighted) average of . The results from formulas (a) and (b)
agree very well with those obtained by standard methods, for all the
perturbation parameters considered. Formula (c) gives reasonably accurate
results for sufficiently small parameters corresponding also to cases of a
considerably nonuniform hyperbolicity. This is due to {\em uniformity sum
rules} satisfied by the PO Lyapunov eigenvalues at {\em fixed} . These sum
rules follow from general arguments and are supported by much numerical
evidence.Comment: 6 Tables, 2 Figures (postscript); To appear in Physical Review
How to dissect viral infections and their interplay with the host-proteome by immunoaffinity and mass spectrometry: A tutorial
The capabilities of bioanalytical mass spectrometry to (i) detect and differentiate viruses at the peptide level whilst maintaining high sample throughput and (ii) to provide diagnosis and prognosis for infected patients are presented as a tutorial in this work to aid analytical chemists and physicians to gain insights into the possibilities offered by current high-resolution mass spectrometry technology and bioinformatics. From (i) sampling to sample treatment; (ii) Matrix-Assisted Laser Desorption Ionization- to Electrospray Ionization -based mass spectrometry; and (iii) from clustering to peptide sequencing; a detailed step-by-step guide is provided and exemplified using SARS-CoV-2 Spike Y839 variant and the variant of concern SARS-CoV-2 Alpha (B.1.1.7 lineage), Influenza B, and Influenza A subtypes AH1N1pdm09 and AH3N2.Highlights: - Immunohistochemistry with magnetic core nanoparticles to isolate viruses. - The use of MALDI-MS for rapid virus detection is explained in detail; - The use of ESI-MS/MS to pinpoint host-patient crosstalk is explained in detail. - The absolute quantitative MS is explained for large-scale protein quantitation.This work received financial support from PT national funds (FCT/MCTES) through the projects UIDB/50006/2020 and UIDP/50006/2020 and from PROTEOMASS Scientific Society through the projects #PM001/2019 and #PM003/2016.info:eu-repo/semantics/publishedVersio
First hexagonal close packed high-entropy alloy with outstanding stability under extreme conditions and electrocatalytic activity for methanol oxidation
High-entropy alloys containing 5 and 6 platinum group metals have been prepared by thermal decomposition of single-source precursors non requiring high temperature or mechanical alloying. The prepared Ir0.19Os0.22Re0.21Rh0.20Ru0.19 alloy is the first example of a single-phase hexagonal high-entropy alloy. Heat treatment up to 1500 K and compression up to 45 GPa do not result in phase changes, a record temperature and pressure stability for a single-phase high-entropy alloy. The alloys show pronounced electrocatalytic activity in methanol oxidation, which opens a route for the use of high-entropy alloys as materials for sustainable energy conversion
- …