1,253 research outputs found

    One-year evolution of symptoms and health status of the copd multi-dimensional phenotypes: Results from the follow-up of the storico observational study

    Get PDF
    Aim: Describing the 1-year evolution of symptoms and health status in COPD patients enrolled in the STORICO study (observational study on characterization of 24-h symptoms in patients with COPD) classified in multidimensional phenotypes (m-phenotypes). Methods: In our previous study, we performed an exploratory factor analysis to identify clinical and pathophysiological variables having the greatest classificatory properties, followed by a cluster analysis to group patients into m-phenotypes (mild COPD (MC), mild emphysematous (ME), severe bronchitic (SB), severe emphysematous (SE), and severe mixed COPD (SMC)). COPD symptoms were recorded at baseline, 6-, and 12-month follow-up and their evolution was described as frequency of patients with always present, always absent, arising’, ‘no more present symptoms. QoL and quality of sleep were evaluated using the SGRQ and CASIS questionnaires, respectively. Results: We analyzed 379 subjects (144 MC, 71 ME, 96 SB, 14 SE, 54 SMC). M-phenotypes were stable over time in terms of presence of symptoms and health status with selected differences in evolution of symptoms in mild vs severe m-phenotypes. Indeed, 28.1% SB, 50.0% SE and 24.1% SMC vs 0.7% MC and 5.6% ME with night-time symptoms at baseline had no more symptoms at 6-month (p-value night-time symptom evolution MC vs SB, SE, SMC and ME vs SB, SE, SMC <0.0001). All m-phenotypes improved in quality of sleep, more markedly the severe than the mild ones (p-values CASIS score change between baseline and 6-or 12-month in MC, ME vs SB, SE, SMC <0.0001). QoL did not change during observation, irrespectively of m-phenotype. Conclusion: Over 1 year, severe m-phenotypes showed an improvement in night-time symptoms and quality of sleep, but not QoL. Being stable over time, m-phenotypes seem worthy of testing for classificatory and prognostic purposes

    Efficacy of dupilumab in atopic comorbidities associated with moderate-to-severe adult atopic dermatitis

    Get PDF
    Background: Dupilumab is an anti-IL-4Rα antibody used in the treatment of patients with moderate-to-severe atopic dermatitis (msAD). This study explored the potential benefit of dupilumab in perennial allergic rhinoconjunctivitis (PAR) and perennial allergic asthma (PAA) caused by indoor allergens in adults with msAD. Methods: This multicentric, prospective, observational, real-life study included adult patients with msAD who had been treated with dupilumab in 16 Italian care centres. Efficacy outcomes regarding AD, PAR and PAA were collected at baseline and 16 weeks. Safety was also assessed. Results: We enrolled 123 patients with msAD. Between baseline and 16 weeks of treatment, the following measurements decreased statistically significantly: Eczema Area and Severity Index, SCOring AD, Patient-Oriented Eczema Measure, pruritus score, sleep score, Dermatology Life Quality Index and IgE. Dupilumab treatment in patients with comorbid PAR (n = 41) was associated with significant improvements in PAR disease control (measured using a Rhinitis Control Scoring System) and in PAR Quality of life (QoL) (measured using the Rhinoconjunctivitis QoL Questionnaire scores). In 32 patients with comorbid PAA, dupilumab significantly improved PAA control (measured using the Asthma Control Test and five-item Asthma Control Questionnaire scores) and disease-related QoL (measured using the Asthma QoL Questionnaire scores). Thirty-five patients (28.5%) developed conjunctivitis during the study period. Conclusion: These results support the benefits of dupilumab for adult patients with PAR and/or PAA associated with msAD

    The CUORE Cryostat: A 1-Ton Scale Setup for Bolometric Detectors

    Get PDF
    The cryogenic underground observatory for rare events (CUORE) is a 1-ton scale bolometric experiment whose detector consists of an array of 988 TeO2 crystals arranged in a cylindrical compact structure of 19 towers. This will be the largest bolometric mass ever operated. The experiment will work at a temperature around or below 10 mK. CUORE cryostat consists of a cryogen-free system based on pulse tubes and a custom high power dilution refrigerator, designed to match these specifications. The cryostat has been commissioned in 2014 at the Gran Sasso National Laboratories and reached a record temperature of 6 mK on a cubic meter scale. In this paper, we present results of CUORE commissioning runs. Details on the thermal characteristics and cryogenic performances of the system will be also given.Comment: 7 pages, 2 figures, LTD16 conference proceedin

    Exploring CEvNS with NUCLEUS at the Chooz Nuclear Power Plant

    Full text link
    Coherent elastic neutrino-nucleus scattering (CEν\nuNS) offers a unique way to study neutrino properties and to search for new physics beyond the Standard Model. Nuclear reactors are promising sources to explore this process at low energies since they deliver large fluxes of (anti-)neutrinos with typical energies of a few MeV. In this paper, a new-generation experiment to study CEν\nuNS is described. The NUCLEUS experiment will use cryogenic detectors which feature an unprecedentedly low energy threshold and a time response fast enough to be operated in above-ground conditions. Both sensitivity to low-energy nuclear recoils and a high event rate tolerance are stringent requirements to measure CEν\nuNS of reactor antineutrinos. A new experimental site, denoted the Very-Near-Site (VNS) at the Chooz nuclear power plant in France is described. The VNS is located between the two 4.25 GWth_{\mathrm{th}} reactor cores and matches the requirements of NUCLEUS. First results of on-site measurements of neutron and muon backgrounds, the expected dominant background contributions, are given. In this paper a preliminary experimental setup with dedicated active and passive background reduction techniques is presented. Furthermore, the feasibility to operate the NUCLEUS detectors in coincidence with an active muon-veto at shallow overburden is studied. The paper concludes with a sensitivity study pointing out the promising physics potential of NUCLEUS at the Chooz nuclear power plant

    Knowledge and Health Care resource allocation: CME/CPD course guidelines-based efficacy

    Get PDF
    Background: Most Health Care Systems consider Continuing Medical Education a potential tool to improve quality of care and reduce disease management costs. Its efficacy in general practitioners needs to be further explored. Objective: This study assesses the effectiveness of a one-year continuing medical education/continuing professional development course for general practitioners, regarding the improvement in knowledge of ARIA and GINA guidelines and compliance with them in asthma management. Methods: Sixty general practitioners, covering 68,146 inhabitants, were randomly allocated to continuing medical education/continuing professional development (five residential events + four short distance-learning refresher courses over one year) or no training. Participants completed a questionnaire after each continuing medical education event; key questions were repeated at least twice. The Local Health Unit prescription database was used to verify prescription habits (diagnostic investigations and pharmacological therapy) and hospitalizations over one year before and after training. Results: Fourteen general practitioners (46.7%) reached the cut-off of 50% attendance of the training courses. Knowledge improved significantly after training (p<0.001, correct answers to key questions +13%). Training resulted in pharmaceutical cost containment (trained general practitioners +0.5% vs controls +18.8%) and greater attention to diagnosis and monitoring (increase in spirometry +63.4%, p<0.01). Conclusion: This study revealed an encouraging impact of educational events on improvement in general practitioner knowledge of guidelines and daily practice behavioral changes. Long-term studies of large populations are required to assess the effectiveness of education on the behavior of physicians in asthma management, and to establish the best format for educational events

    The CUORE cryostat: an infrastructure for rare event searches at millikelvin temperatures

    Full text link
    The CUORE experiment is the world's largest bolometric experiment. The detector consists of an array of 988 TeO2 crystals, for a total mass of 742 kg. CUORE is presently taking data at the Laboratori Nazionali del Gran Sasso, Italy, searching for the neutrinoless double beta decay of 130Te. A large custom cryogen-free cryostat allows reaching and maintaining a base temperature of about 10 mK, required for the optimal operation of the detector. This apparatus has been designed in order to achieve a low noise environment, with minimal contribution to the radioactive background for the experiment. In this paper, we present an overview of the CUORE cryostat, together with a description of all its sub-systems, focusing on the solutions identified to satisfy the stringent requirements. We briefly illustrate the various phases of the cryostat commissioning and highlight the relevant steps and milestones achieved each time. Finally, we describe the successful cooldown of CUORE

    CUPID-0: the first array of enriched scintillating bolometers for 0decay investigations

    Get PDF
    The CUPID-0 detector hosted at the Laboratori Nazionali del Gran Sasso, Italy, is the first large array of enriched scintillating cryogenic detectors for the investigation of82Se neutrinoless double-beta decay (0). CUPID-0 aims at measuring a background index in the region of interest (RoI) for 0at the level of 10- 3 counts/(keV kg years), the lowest value ever measured using cryogenic detectors. CUPID-0 operates an array of Zn82Se scintillating bolometers coupled with bolometric light detectors, with a state of the art technology for background suppression and thorough protocols and procedures for the detector preparation and construction. In this paper, the different phases of the detector design and construction will be presented, from the material selection (for the absorber production) to the new and innovative detector structure. The successful construction of the detector lead to promising preliminary detector performance which is discussed here
    corecore