168 research outputs found

    Preconditioning Maximal Center Gauge with Stout Link Smearing in SU(3)

    Get PDF
    Center vortices are studied in SU(3) gauge theory using Maximal Center Gauge (MCG) fixing. Stout link smearing and over-improved stout link smearing are used to construct a preconditioning gauge field transformation, applied to the original gauge field before fixing to MCG. We find that preconditioning successfully achieves higher gauge fixing maxima. We observe a reduction in the number of identified vortices when preconditioning is used, and also a reduction in the vortex-only string tension.Comment: 9 pages, 4 figure

    Charmonium spectral functions in Nf=2 QCD

    Get PDF
    We report on a study of charmonium at high temperature in 2-flavour QCD. This is the first such study with dynamical fermions. Using an improved anisotropic lattice action, spectral functions are extracted from correlators in the vector and pseudoscalar channels. No signs of medium-induced suppression of the ground states are seen for temperatures up to 1.5T_c, while at T~2T_c there are clear signs of modifications. The current systematic and statistical uncertainties in our data, in particular the relatively coarse lattice and small volume, do not allow us to draw a firm conclusion at this stage.Comment: 6 pages, talk by JIS at Lattice 2005 (Non-zero temperature and density

    Strong absorption by interstellar hydrogen fluoride: Herschel/HIFI observations of the sight-line to G10.6-0.4 (W31C)

    Full text link
    We report the detection of strong absorption by interstellar hydrogen fluoride along the sight-line to the submillimeter continuum source G10.6-0.4 (W31C). We have used Herschel's HIFI instrument, in dual beam switch mode, to observe the 1232.4763 GHz J=1-0 HF transition in the upper sideband of the Band 5a receiver. The resultant spectrum shows weak HF emission from G10.6-0.4 at LSR velocities in the range -10 to -3 km/s, accompanied by strong absorption by foreground material at LSR velocities in the range 15 to 50 km/s. The spectrum is similar to that of the 1113.3430 GHz 1(11)-0(00) transition of para-water, although at some frequencies the HF (hydrogen fluoride) optical depth clearly exceeds that of para-H2O. The optically-thick HF absorption that we have observed places a conservative lower limit of 1.6E+14 cm-2 on the HF column density along the sight-line to G10.6-0.4. Our lower limit on the HF abundance, 6E-9 relative to hydrogen nuclei, implies that hydrogen fluoride accounts for between ~ 30 and 100% of the fluorine nuclei in the gas phase along this sight-line. This observation corroborates theoretical predictions that - because the unique thermochemistry of fluorine permits the exothermic reaction of F atoms with molecular hydrogen - HF will be the dominant reservoir of interstellar fluorine under a wide range of conditions.Comment: Accepted for publication in Astronomy and Astrophysics (Herschel special issue). This revised version corrects a typographic error in the HTML abstract, in which the lower limit on the HF abundance (should be 6E-9) was previously misstated. The abstract in the PDF version is correct and the latter has not been modifie

    Nitrogen hydrides in interstellar gas: Herschel/HIFI observations towards G10.6-0.4 (W31C)

    Get PDF
    The HIFI instrument on board the Herschel Space Observatory has been used to observe interstellar nitrogen hydrides along the sight-line towards G10.6-0.4 in order to improve our understanding of the interstellar chemistry of nitrogen. We report observations of absorption in NH N=1-0, J=2-1 and ortho-NH2 1_1,1-0_0,0. We also observed ortho-NH3 1_0-0_0, and 2_0-1_0, para-NH3 2_1-1_1, and searched unsuccessfully for NH+. All detections show emission and absorption associated directly with the hot-core source itself as well as absorption by foreground material over a wide range of velocities. All spectra show similar, non-saturated, absorption features, which we attribute to diffuse molecular gas. Total column densities over the velocity range 11-54 km/s are estimated. The similar profiles suggest fairly uniform abundances relative to hydrogen, approximately 6*10^-9, 3*10^-9, and 3*10^-9 for NH, NH2, and NH3, respectively. These abundances are discussed with reference to models of gas-phase and surface chemistry.Comment: 5 pages, 3 figures, 2 online pages with 2 figures. Accepted for publication in A&A July 6 (Herschel/HIFI special issue

    Ortho-to-para ratio of interstellar heavy water

    Get PDF
    Despite the low elemental deuterium abundance in the Galaxy, enhanced molecular D/H ratios have been found in the environments of low-mass star forming regions, and in particular the Class 0 protostar IRAS 16293-2422. The CHESS (Chemical HErschel Surveys of Star forming regions) Key Program aims at studying the molecular complexity of the interstellar medium. The high sensitivity and spectral resolution of the HIFI instrument provide a unique opportunity to observe the fundamental 1,1,1 - 0,0,0 transition of the ortho-D2O molecule, inaccessible from the ground, and to determine the ortho-to-para D2O ratio. We have detected the fundamental transition of the ortho-D2O molecule at 607.35 GHz towards IRAS 16293-2422. The line is seen in absorption with a line opacity of 0.62 +/- 0.11 (1 sigma). From the previous ground-based observations of the fundamental 1,1,0 - 1,0,1 transition of para-D2O seen in absorption at 316.80 GHz we estimate a line opacity of 0.26 +/- 0.05 (1 sigma). We show that the observed absorption is caused by the cold gas in the envelope of the protostar. Using these new observations, we estimate for the first time the ortho to para D2O ratio to be lower than 2.6 at a 3 sigma level of uncertainty, to be compared with the thermal equilibrium value of 2:1.Comment: 5 pages, 5 figures, accepted the A&A HIFI Special Issue as a lette

    A Large Area Detector proposed for the Large Observatory for X-ray Timing (LOFT)

    Full text link
    The Large Observatory for X-ray Timing (LOFT) is one of the four candidate ESA M3 missions considered for launch in the 2022 time-frame. It is specifically designed to perform fast X-ray timing and probe the status of the matter near black holes and neutron stars. The LOFT scientific payload is composed of a Large Area Detector (LAD) and a Wide Field Monitor (WFM). The LAD is a 10 m2-class pointed instrument with 20 times the collecting area of the best past timing missions (such as RXTE) over the 2-30 keV range, which holds the capability to revolutionize studies of X-ray variability down to the millisecond time scales. Its ground-breaking characteristic is a low mass per unit surface, enabling an effective area of ~10 m^2 (@10 keV) at a reasonable weight. The development of such large but light experiment, with low mass and power per unit area, is now made possible by the recent advancements in the field of large-area silicon detectors - able to time tag an X-ray photon with an accuracy <10 {\mu}s and an energy resolution of ~260 eV at 6 keV - and capillary-plate X-ray collimators. In this paper, we will summarize the characteristics of the LAD instrument and give an overview of its capabilities.Comment: Proceedings of SPIE, Vo. 8443, Paper No. 8443-8

    Nosocomial outbreak of Pantoea agglomerans bacteraemia associated with contaminated anticoagulant citrate dextrose solution: new name, old bug?

    Get PDF
    We describe an outbreak investigation of Pantoea agglomerans bacteraemia associated with anticoagulant citrate-dextrose 46% (ACD) solution prepared in-house. A healthy man presented with septic shock during plasmapheresis for granulocyte donation. The solution used for priming and blood samples were sent for culture. Identification of the isolate to species level was performed by gyrB sequencing. Typing was performed by pulsed-field gel electrophoresis (PFGE). In total, eight cases were identified during a three-week period. P. agglomerans was also cultured from six ACD solution bags. Isolates from patients and ACD bags were identical by PFGE. All isolates were susceptible to ampicillin, cephazolin, gentamicin, ciprofloxacin, cefepime and imipenem. (C) 2011 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved

    The SuperCam Remote Sensing Instrument Suite for Mars 2020

    No full text
    International audienceThe Mars 2020 rover, essentially a structural twin of MSL, is being built to a) characterize the geology and history of a new landing site on Mars, b) find and characterize ancient habitable environments, c) cache samples for eventual return to Earth, and d) demonstrate in-situ production of oxygen needed for human exploration. Remote-sensing instrumentation is needed to support the first three of these goals [1]. The SuperCam instrument meets these needs with a range of instrumentation including the highest-resolution remote imaging on the rover, two different techniques for determining mineralogy , and one technique to provide elemental compositions. All of these techniques are co-boresighted, providing rapid comprehensive characterization. In addition, for targets within 7 meters of the rover the laser shock waves brush away the dust, providing cleaner surfaces for analysis. SuperCam will use an advanced version of the AEGIS robotic target selection software
    • 

    corecore