181 research outputs found
Comparison of the CDC Backpack aspirator and the Prokopack aspirator for sampling indoor- and outdoor-resting mosquitoes in southern Tanzania.
BACKGROUND\ud
\ud
Resting mosquitoes can easily be collected using an aspirating device. The most commonly used mechanical aspirator is the CDC Backpack aspirator. Recently, a simple, and low-cost aspirator called the Prokopack has been devised and proved to have comparable performance. The following study evaluates the Prokopack aspirator compared to the CDC backpack aspirator when sampling resting mosquitoes in rural Tanzania.\ud
\ud
METHODS\ud
\ud
Mosquitoes were sampled in- and outdoors of 48 typical rural African households using both aspirators. The aspirators were rotated between collectors and households in a randomized, Latin Square design. Outdoor collections were performed using artificial resting places (large barrel and car tyre), underneath the outdoor kitchen (kibanda) roof and from a drop-net. Data were analysed with generalized linear models.\ud
\ud
RESULTS\ud
\ud
The number of mosquitoes collected using the CDC Backpack and the Prokopack aspirator were not significantly different both in- and outdoors (indoors p = 0.735; large barrel p = 0.867; car tyre p = 0.418; kibanda p = 0.519). The Prokopack was superior for sampling of drop-nets due to its smaller size. The number mosquitoes collected per technician was more consistent when using the Prokopack aspirator. The Prokopack was more user-friendly: technicians preferred using the it over the CDC backpack aspirator as it weighs considerably less, retains its charge for longer and is easier to manoeuvre.\ud
\ud
CONCLUSIONS\ud
\ud
The Prokopack proved in the field to be more advantageous than the CDC Backpack aspirator. It can be self assembled using simple, low-cost and easily attainable materials. This device is a useful tool for researchers or vector-control surveillance programs operating in rural Africa, as it is far simpler and quicker than traditional means of sampling resting mosquitoes. Further longitudinal evaluations of the Prokopack aspirator versus the gold standard pyrethrum spray catch for indoor resting catches are recommended
Precision measurement of the top quark mass from dilepton events at CDF II
We report a measurement of the top quark mass, M_t, in the dilepton decay
channel of
using an integrated luminosity of 1.0 fb^{-1} of p\bar{p} collisions collected
with the CDF II detector. We apply a method that convolutes a leading-order
matrix element with detector resolution functions to form event-by-event
likelihoods; we have enhanced the leading-order description to describe the
effects of initial-state radiation. The joint likelihood is the product of the
likelihoods from 78 candidate events in this sample, which yields a measurement
of M_{t} = 164.5 \pm 3.9(\textrm{stat.}) \pm 3.9(\textrm{syst.})
\mathrm{GeV}/c^2, the most precise measurement of M_t in the dilepton channel.Comment: 7 pages, 2 figures, version includes changes made prior to
publication by journa
Measurement of the Ratios of Branching Fractions B(Bs -> Ds pi pi pi) / B(Bd -> Dd pi pi pi) and B(Bs -> Ds pi) / B(Bd -> Dd pi)
Using 355 pb^-1 of data collected by the CDF II detector in \ppbar collisions
at sqrt{s} = 1.96 TeV at the Fermilab Tevatron, we study the fully
reconstructed hadronic decays B -> D pi and B -> D pi pi pi. We present the
first measurement of the ratio of branching fractions B(Bs -> Ds pi pi pi) /
B(Bd -> Dd pi pi pi) = 1.05 pm 0.10 (stat) pm 0.22 (syst). We also update our
measurement of B(Bs -> Ds pi) / B(Bd -> Dd pi) to 1.13 pm 0.08 (stat) pm 0.23
(syst) improving the statistical uncertainty by more than a factor of two. We
find B(Bs -> Ds pi) = [3.8 pm 0.3 (stat) pm 1.3 (syst)] \times 10^{-3} and B(Bs
-> Ds pi pi pi) = [8.4 pm 0.8 (stat) pm 3.2 (syst)] \times 10^{-3}.Comment: 7 pages, 2 figure
Cross Section Measurements of High- Dilepton Final-State Processes Using a Global Fitting Method
We present a new method for studying high- dilepton events
(, , ) and simultaneously
extracting the production cross sections of , , and p\bar{p} \to \ztt at a center-of-mass energy of TeV. We perform a likelihood fit to the dilepton data in a parameter
space defined by the missing transverse energy and the number of jets in the
event. Our results, which use of data recorded with the CDF
II detector at the Fermilab Tevatron Collider, are pb, pb, and
\sigma(\ztt) =291^{+50}_{-46} pb.Comment: 20 pages, 2 figures, to be submitted to PRD-R
Measurement of the Lambda_b Lifetime in Lambda_b --> J/psi Lambda0 in p-pbar Collisions at sqrt(s)=1.96 TeV
We report a measurement of the Lambda_b lifetime in the exclusive decay
Lambda_b --> J/psi Lambda0 in p-pbar collisions at sqrt(s) = 1.96 TeV using an
integrated luminosity of 1.0 fb^{-1} of data collected by the CDF II detector
at the Fermilab Tevatron. Using fully reconstructed decays, we measure
tau(Lambda_b) = 1.593 ^{+0.083}_{-0.078} (stat.) +- 0.033 (syst.) ps. This is
the single most precise measurement of tau(Lambda_b) and is 3.2 sigma higher
than the current world average.Comment: 7 Pages, 2 Figures, 1 Table. Submitted to Phys. Rev. Let
Measurement of Lifetime and Decay-Width Difference in B0s -> J/psi phi Decays
We measure the mean lifetime, tau=2/(Gamma_L+Gamma_H), and the width
difference, DeltaGamma=Gamma_L-Gamma_H, of the light and heavy mass eigenstates
of the B0s meson, B0sL and B0sH, in B0s -> J/psi phi decays using 1.7 fb^-1 of
data collected with the CDF II detector at the Fermilab Tevatron ppbar
collider. Assuming CP conservation, a good approximation for the B0s system in
the Standard Model, we obtain DeltaGamma = 0.076^+0.059_-0.063 (stat.) +- 0.006
(syst.) ps^-1 and tau = 1.52 +- 0.04 (stat.) +- 0.02 (syst.) ps, the most
precise measurements to date. Our constraints on the weak phase and DeltaGamma
are consistent with CP conservation.
Dedicated to the memory of our dear friend and colleague, Michael P. Schmid
Limits on Anomalous Triple Gauge Couplings in ppbar Collisions at sqrt{s}=1.96 TeV
We present a search for anomalous triple gauge couplings (ATGC) in WW and WZ
boson production. The boson pairs are produced in ppbar collisions at
sqrt{s}=1.96 TeV, and the data sample corresponds to 350 pb-1 of integrated
luminosity collected with the CDF II detector at the Fermilab Tevatron. In this
search one W decays to leptons, and the other boson (W or Z) decays
hadronically. Combining with a previously published CDF measurement of Wgamma
boson production yields ATGC limits of -0.18 < lambda < 0.17 and -0.46 < Delta
kappa < 0.39 at the 95% confidence level, using a cut-off scale Lambda=1.5 TeV.Comment: 7 pages, 3 figures. Submitted to Phys. Rev.
Analysis of the Quantum Numbers of the X(3872) Particle
We present an analysis of angular distributions and correlations of the
X(3872) particle in the exclusive decay mode X(3872)->J/psi pi+ pi- with
J/psi->mu+ mu-. We use 780 pb -1 of data from ppbar collisions at sqrt{s} =
1.96 TeV collected with the CDF II detector at the Fermilab Tevatron. We derive
constraints on spin, parity, and charge conjugation parity of the X(3872)
particle by comparing measured angular distributions of the decay products with
predictions for different JPC hypotheses. The assignments JPC = 1++ and 2-+ are
the only ones consistent with the data.Comment: update to journal versio
Observation of WZ Production
We report the first observation of the associated production of a W boson and
a Z boson. This result is based on 1.1 fb-1 of integrated luminosity from ppbar
collisions at sqrt{s} = 1.96 TeV collected with the CDF II detector at the
Fermilab Tevatron. We observe 16 WZ candidates passing our event selection with
an expected background of 2.7 +/- 0.4 events. A fit to the missing transverse
energy distribution indicates an excess of events compared to the background
expectation corresponding to a significance equivalent to six standard
deviations. The measured cross section is sigma(ppbar -> WZ) =
5.0^{+1.8}_{-1.6} pb, consistent with the standard model expectation.Comment: 7 pages, 3 figures. Submitted to Phys. Rev. Let
Measurement of the Top-Quark Mass in All-Hadronic Decays in p pbar Collisions at CDF II
We present a measurement of the top-quark mass, , in the
all-hadronic decay channel . The analysis is performed using 310 pb of
=1.96 TeV collisions collected with the CDF II detector
using a multi-jet trigger. The mass measurement is based on an event-by-event
likelihood which depends on both the sample purity and the value of the
top-quark mass, using 90 possible jet-to-parton assignments in the six-jet
final state. The joint likelihood of 290 selected events yields a value of
=177.1 4.9 (stat.) 4.7 (syst.) GeV/.Comment: 7 pages, 2 figures and 1 table, Submitted to Phys. Rev. Let
- …