    Single-lap shear bond tests on Steel Reinforced Geopolymeric Matrix-concrete joints

    Get PDF
    YesNowadays Fiber Reinforced Polymers (FRPs) represent a well-established technique for rehabilitation of Reinforced Concrete (RC) and masonry structures. However, the severe degradation of mechanical properties of FRP under high temperature and fire as well as poor sustainability represents major weak points of organic-based systems. The use of eco-friendly inorganic geopolymeric matrices, alternative to the polymeric resins, would be highly desirable to overcome these issues. The present work aims to investigate the bond characteristic of a novel Steel Reinforced Geopolymeric Matrix (SRGM) strengthening system externally bonded to a concrete substrate having low mechanical properties. SRGM composite material consists of stainless steel cords embedded into a fireproof geopolymeric matrix. Single-lap shear tests by varying the bonded length were carried out. The main failure mode observed of SRGM-concrete joints was debonding at the fiber-matrix interface. Test results also suggest the effective bond length. On the basis of the experimental results, a cohesive bond-slip law was proposed.Part of the analyses were developed within the activities of Rete dei Laboratori Universitari di Ingegneria Sismica (ReLUIS) for the research program funded by the Dipartimento di Protezione Civile (DPC), Progetto DPC/ReLUIS 2016–AQ DPC/ReLUIS 2014–2016

    Experimental investigation on the bond behavior of a compatible TRM-based solution for rammed earth heritage

    Get PDF
    Despite the current awareness of the high seismic risk of earthen structures, little has been done so far to develop proper strengthening solutions for the rammed earth heritage. Based on the effectiveness of TRM for masonry buildings, the strengthening of rammed earth walls with externally bonded fibers using earth-based mortar is being proposed as a compatible solution. In this context, the investigation of bond behavior was conducted by means of direct tensile tests, pull-out tests and single lap-shear tests. The specimens were prepared using earth-based mortars and two different types of meshes (glass and nylon) while considering different-bonded lengths. The direct tensile tests on TRM coupons showed the high capacity of the nylon mesh in transferring stresses after cracking of the mortar. The pull-out tests highlighted that in the case of glass fiber mesh, the bond was granted by friction, while the mechanical anchorage promoted by the transversal yarns granted the bond of the nylon mesh. Finally, the single lap-shear tests showed that the adopted earth-based mortar seems to limit the performance of the strengthening.This work was supported by the Fundacao para a Ciencia e a Tecnologia [PTDC/ECM-EST/2777/2014, SFRH/BD/131006/2017, SFRH/BPD/97082/2013]
    corecore