75 research outputs found

    Pull-out and push-in tests of bonded steel strands

    Full text link
    MartĂ­ Vargas, JR. (2013). Pull-out and push-in tests of bonded steel strands. Magazine of Concrete Research. 65(18):1128-1131. doi:10.1680/macr.13.00061S112811316518BalĂĄzs LG .Bond Model with Non-Linear Bond-Slip Law, 1987, Politecnico di Milano, Italy, 395–430, Studi e Ricerche, Post-Graduate Course for Reinforced Concrete Structures, V.8/86.Balazs, G. L. (1992). Transfer Control of Prestressing Strands. PCI Journal, 37(6), 60-71. doi:10.15554/pcij.11011992.60.71Balazs, G. L. (1993). Transfer Length of Prestressing Strand as a Function of Draw-In and Initial Prestress. PCI Journal, 38(2), 86-93. doi:10.15554/pcij.03011993.86.93BalĂĄzs, G. L. (2007). Connecting Reinforcement to Concrete by Bond. Beton- und Stahlbetonbau, 102(S1), 46-50. doi:10.1002/best.200710109Carmo RNF .Ancoragem de Armaduras PrĂ©-Esforçadas por PrĂ©-TensĂŁo. MSc thesis, 1999, Faculdade de CiĂȘncias e Tecnologia, Universidade de Coimbra, Portugal, (in Portuguese).Faria, D. M. V., LĂșcio, V. J. G., & Pinho Ramos, A. (2011). Pull-out and push-in tests of bonded steel strands. Magazine of Concrete Research, 63(9), 689-705. doi:10.1680/macr.2011.63.9.689Faria, D. M. V., LĂșcio, V. J. G., & Ramos, A. P. (2011). Strengthening of flat slabs with post-tensioning using anchorages by bonding. Engineering Structures, 33(6), 2025-2043. doi:10.1016/j.engstruct.2011.02.039Faria, D. M. V., LĂșcio, V. J. G., & Pinho Ramos, A. (2012). Post-punching behaviour of flat slabs strengthened with a new technique using post-tensioning. Engineering Structures, 40, 383-397. doi:10.1016/j.engstruct.2012.03.014Laldji S .Bond Characteristics of Prestressing Strand in Grout. MPhil thesis, 1987, University of Leicester, UK.Laldji, S., & Young, A. G. (1988). Bond between steel strand and cement grout in ground anchorages. Magazine of Concrete Research, 40(143), 90-98. doi:10.1680/macr.1988.40.143.90Lopes, S. M. R., & do Carmo, R. N. F. (2002). Bond of prestressed strands to concrete: transfer rate and relationship between transmission length and tendon draw-in. Structural Concrete, 3(3), 117-126. doi:10.1680/stco.2002.3.3.117MartĂ­-Vargas, J. R., Serna-Ros, P., FernĂĄndez-Prada, M. A., Miguel-Sosa, P. F., & ArbelĂĄez, C. A. (2006). Test method for determination of the transmission and anchorage lengths in prestressed reinforcement. Magazine of Concrete Research, 58(1), 21-29. doi:10.1680/macr.2006.58.1.21Marti-Vargas, J. R., Arbelaez, C. A., Serna-Ros, P., Navarro-Gregori, J., & Pallares-Rubio, L. (2007). Analytical model for transfer length prediction of 13 mm prestressing strand. Structural Engineering and Mechanics, 26(2), 211-229. doi:10.12989/sem.2007.26.2.211Palmer, K. D., & Schultz, A. E. (2011). Experimental investigation of the web-shear strength of deep hollow-core units. PCI Journal, 56(4), 83-104. doi:10.15554/pcij.09012011.83.10

    Modeling for assessment of long-term behavior of prestressed concrete box-girder bridges

    Get PDF
    Large-span prestressed concrete (PC) box-girder bridges suffer excessive vertical deflections and cracking. Recent serviceability failures in China show that the current Chinese standard modeling approach fails to accurately predict long-term deformations of large box-girder bridges. This hinders the efforts of inspectors to conduct satisfactory structural assessments and make decisions on potential repair and strengthening. This study presents a model-updating approach that aims to assess the models used in the current Chinese standard and improve the accuracy of numerical modeling of the long-term behavior of box-girder bridges, calibrated against data obtained from a bridge in service. A three-dimensional finite-element model representing the long-term behavior of box-girder sections is initially established. Parametric studies are then conducted to determine the relevant influencing parameters and to quantify the relationships between those and the behavior of box-girder bridges. Genetic algorithm optimization, based on the response-surface method (RSM), is used to determine realistic creep and shrinkage levels and prestress losses. The modeling results correspond well with the measured historic deflections and the observed cracks. This approach can lead to more accurate bridge assessments, which result in safer strengthening and more economic maintenance plans

    CFRP flexural and shear strengthening technique for RC beams : experimental and numerical research

    Get PDF
    Near surface mounted (NSM) technique has proved to be a very effective technique for the flexural strengthening of RC beams. Due to the relatively small thickness of the concrete cover that several beams present, cutting the bottom arm of steel stirrups for the installation of NSM laminates might be a possible strategy, whose implications on the beam’s load carrying capacity need to be assessed. When steel stirrups are cut, however, the shear resistance can be a concern. This also happens when a strengthening intervention is carried out to increase the flexural resistance of a beam, since in certain cases it is also necessary to increase the shear resistance in order to avoid the occurrence of brittle shear failure. The present work assesses the effectiveness of a technique that aims to increase both the flexural and shear resistance of RC beams that have the bottom arm of the steel stirrups cut for the application of NSM laminates. This assessment is performed by experimental and numerical research. The main results of the experimental program are presented and analyzed, and the innovative aspects of a constitutive model implemented in a computer program are described, being their virtues and deficiencies discussed.The study reported in this paper forms a part of the research program "CUTINEMO - Carbon fiber laminates applied according to the near surface mounted technique to increase the flexural resistance to negative moments of continuous reinforced concrete structures" supported by FCT, PTDC/ECM/73099/2006. The authors wish to acknowledge the support also provided by the S&P, Casais and Artecanter Companies. The second Author acknowledges the grant under the aforementioned research project. The third author acknowledges the financial support of FCT, PhD Grant number SFRH/BD/23326/2005

    Deflection control for reinforced recycled aggregate concrete beams: Experimental database and extension of the fib Model Code 2010 model

    Get PDF
    Recycled aggregate concrete (RAC) has emerged as a viable solution for solving some of the environmental problems of concrete production. However, design guidelines for deflection control of reinforced RAC members have not yet been proposed. This study presents a comprehensive analysis of the applicability of the fib Model Code 2010 (MC2010) deflection control model to reinforced RAC beams. Three databases of long-term studies on natural aggregate concrete (NAC) and RAC beams were compiled and meta-analyses of deflection predictions by MC2010 were performed. First, the MC2010 deflection control model was tested against a large database of long-term tests on NAC beams. Second, a database of RAC and companion NAC beams was compiled and initial and long-term deflections were calculated using the MC2010 model. It was shown that deflections of RAC beams are significantly underestimated relative to NAC beams. Previously proposed modifications for MC2010 equations for shrinkage strain and creep coefficient were used, and new modifications for the modulus of elasticity and empirical coefficient ÎČ were proposed. The improved MC2010 deflection control model on RAC beams was shown to have equal performance to that on companion NAC beams. The proposals presented in this paper can help engineers to more reliably perform deflection control of reinforced RAC members.This is the peer-reviewed version of the article: N. ToĆĄić, S. Marinković, and J. de Brito, ‘Deflection control for reinforced recycled aggregate concrete beams: Experimental database and extension of the fib Model Code 2010 model’, Structural Concrete, vol. 20, no. 6, pp. 2015–2029, 2019 [https://doi.org/10.1002/suco.201900035

    Influence of mechanical and geometrical properties of embedded long-gauge strain sensors on the accuracy of strain measurement

    Full text link
    In many civil and geotechnical applications it is of interest to monitor the strain deep inside the structure; consequently, it is necessary to embed the sensors into the structure's material. Construction and geotechnical materials, such as concrete and soil, can be affected by local defects, e.g. cracks, air pockets and inclusions. To monitor these materials at a structural level it is necessary to use long-gauge sensors. As the sensor has to be embedded in the host material, its presence causes perturbation of the strain field and influences the accuracy of the strain measurement. The aim of this research was to identify the critical parameters that influence the accuracy of the strain measurement, to study how these parameters affect the accuracy, and to give recommendations for sensor users. The study was based on finite element analysis and all involved materials were assumed to have the MöhrCoulomb elastic, perfectly plastic behavior. A suitability of the numerical model for the analysis was verified using the experimental results of two cases reported in the literature and one on-site application. The study revealed that the most important parameters that influence the accuracy of the strain measurement are the goodness of interaction (strain transfer) between the host material and the anchor pieces of the sensor, the ratio between equivalent Young's modulus of the sensor and the Young's modulus of the host material, the radius of the anchor piece and the gauge length. The numerical model and parametric study are presented in detail along with practical recommendations. © 2012 IOP Publishing Ltd.The authors would like to thank the Spanish Ministry of Education, with support received under the National Program for Mobility of Researchers (O.M. EDU/1456/2010, ref. PR2010-0293) which enabled the joint work that made this study possible. The Streicker Bridge project was realized with help of Turner Construction Co., HNTB, AG Construction Corp., Vollers Excavating & Constr., SMARTEC SA, Micron Optics, Princeton Facilities, and staff and students of CEE department of Princeton University.CalderĂłn GarcĂ­a, PA.; Glisic, B. (2012). Influence of mechanical and geometrical properties of embedded long-gauge strain sensors on the accuracy of strain measurement. Measurement Science and Technology. (23):1-15. https://doi.org/10.1088/0957-0233/23/6/065604S11523GliĆĄić, B., & Inaudi, D. (2007). Fibre Optic Methods for Structural Health Monitoring. doi:10.1002/9780470517819Ansari, F. (2007). Practical Implementation of Optical Fiber Sensors in Civil Structural Health Monitoring. Journal of Intelligent Material Systems and Structures, 18(8), 879-889. doi:10.1177/1045389x06075760Li, H.-N., Zhou, G.-D., Ren, L., & Li, D.-S. (2009). Strain Transfer Coefficient Analyses for Embedded Fiber Bragg Grating Sensors in Different Host Materials. Journal of Engineering Mechanics, 135(12), 1343-1353. doi:10.1061/(asce)0733-9399(2009)135:12(1343)Torres, B., PayĂĄ-Zaforteza, I., CalderĂłn, P. A., & Adam, J. M. (2011). Analysis of the strain transfer in a new FBG sensor for Structural Health Monitoring. Engineering Structures, 33(2), 539-548. doi:10.1016/j.engstruct.2010.11.012Kesavan, K., Ravisankar, K., Parivallal, S., Sreeshylam, P., & Sridhar, S. (2010). Experimental studies on fiber optic sensors embedded in concrete. Measurement, 43(2), 157-163. doi:10.1016/j.measurement.2009.08.010Azenha, M., Faria, R., & Ferreira, D. (2009). Identification of early-age concrete temperatures and strains: Monitoring and numerical simulation. Cement and Concrete Composites, 31(6), 369-378. doi:10.1016/j.cemconcomp.2009.03.004Glisic, B. (2011). Influence of the gauge length on the accuracy of long-gauge sensors employed in monitoring of prismatic beams. Measurement Science and Technology, 22(3), 035206. doi:10.1088/0957-0233/22/3/035206Leng, J. S., Winter, D., Barnes, R. A., Mays, G. C., & Fernando, G. F. (2006). Structural health monitoring of concrete cylinders using protected fibre optic sensors. Smart Materials and Structures, 15(2), 302-308. doi:10.1088/0964-1726/15/2/009CalderĂłn, P. A., Adam, J. M., Ivorra, S., PallarĂ©s, F. J., & GimĂ©nez, E. (2009). Design strength of axially loaded RC columns strengthened by steel caging. Materials & Design, 30(10), 4069-4080. doi:10.1016/j.matdes.2009.05.014Adam, J. M., Ivorra, S., PallarĂ©s, F. J., GimĂ©nez, E., & CalderĂłn, P. A. (2009). Axially loaded RC columns strengthened by steel caging. Finite element modelling. Construction and Building Materials, 23(6), 2265-2276. doi:10.1016/j.conbuildmat.2008.11.014Adam, J. M., Ivorra, S., Pallares, F. J., JimĂ©nez, E., & CalderĂłn, P. A. (2008). Column–joint assembly in RC columns strengthened by steel caging. Proceedings of the Institution of Civil Engineers - Structures and Buildings, 161(6), 337-348. doi:10.1680/stbu.2008.161.6.337Adam, J. M., Ivorra, S., Pallares, F. J., GimĂ©nez, E., & CalderĂłn, P. A. (2009). Axially loaded RC columns strengthened by steel cages. Proceedings of the Institution of Civil Engineers - Structures and Buildings, 162(3), 199-208. doi:10.1680/stbu.2009.162.3.199Johansson, M., & Gylltoft, K. (2001). Structural behavior of slender circular steel-concrete composite columns under various means of load application. Steel and Composite Structures, 1(4), 393-410. doi:10.12989/scs.2001.1.4.393Johansson, M., & Gylltoft, K. (2002). Mechanical Behavior of Circular Steel–Concrete Composite Stub Columns. Journal of Structural Engineering, 128(8), 1073-1081. doi:10.1061/(asce)0733-9445(2002)128:8(1073

    Optimization of buttressed earth-retaining walls using hybrid harmony search algorithms

    Full text link
    This paper represents an economic optimization of buttressed earth-retaining walls. We explore the optimum solutions using a harmony search with an intensification stage through threshold accepting. The calibration of the resulting algorithm has been obtained as a result of several test runs for different parameters. A design parametric study was computed to walls in series from 4 to 16 m total height. The results showed different ratios of reinforcement per volume of concrete for three types of ground fill. Our main findings confirmed that the most sensitive variable for optimum walls is the wall-friction angle. The preference for wall-fill friction angles different to 0 in project design is confirmed. The type of fill is stated as the main key factor affecting the cost of optimum walls. The design parametric study shows that the soil foundation bearing capacity substantially affects costs, mainly in coarse granular fills (F1). In that sense, cost-optimum walls are less sensitive to the bearing capacity in mixed soils (F2) and fine soils of low plasticity (F3). Our results also showed that safety against sliding is a more influential factor for optimum buttressed walls than the overturning constraint. Finally, as for the results derived from the optimization procedure, a more suitable rule of thumb to dimension the footing thickness of the footing is proposed.This research was funded by the European Institute of Innovation and Technology under grant agreement no 20140262 Low Carbon Strategy in the Construction Industry (PGA_APED0094_2014-2.1-278-P066-10) and the Spanish Ministry of Economy and Competitiveness along with FEDER funding (Project BIA2014-56574-R).Molina Moreno, F.; García-Segura, T.; Martí Albiñana, JV.; Yepes, V. (2017). Optimization of buttressed earth-retaining walls using hybrid harmony search algorithms. Engineering Structures. 134:205-216. https://doi.org/10.1016/j.engstruct.2016.12.042S20521613

    Flexural strengthening of RC continuous slab strips using NSM CFRP laminates

    Get PDF
    To assess the effectiveness of the near surface mounted (NSM) technique, in terms of load carrying and moment redistribution capacities, for the flexural strengthening of continuous reinforced concrete (RC) slabs, an experimental program was carried out. The experimental program is composed of three series of three slab strips of two equal span length, in order to verify the possibility of increasing the negative (at the intermediate support region) resisting bending moment in 25% and 50% and maintaining moment redistribution levels of 15%, 30% and 45%. Though the flexural resistance of the NSM strengthened sections has exceeded the target values, the moment redistribution was relatively low, and the increase of the load carrying capacity of the strengthened slabs did not exceed 25%. This experimental program is analyzed to highlight the possibilities of NSM technique for statically indeterminate RC slabs in terms of flexural strengthening effectiveness, moment redistribution and ductility performance. Using a FEM-based computer program, which predictive performance was appraised using the obtained experimental results, a high effective NSM flexural strengthening strategy is proposed, capable of enhancing the slab’s load carrying capacity and maintaining high levels of ductility.The study reported in this paper forms a part of the research program "CUTINEMO - Carbon fiber laminates applied according to the near surface mounted technique to increase the flexural resistance to negative moments of continuous reinforced concrete structures" supported by FCT, PTDC/ECM/73099/2006. The authors wish to acknowledge the support also provided by the S&P, Casais and Artecanter Companies. The first Author acknowledges the financial support of National Council for Scientific and Technological Development (CNPq) - Brazil, Ph.D. Grant no. 200953/2007-9. The second Author wishes to acknowledge the support provided by FCT, by means of the SFRH/BSAB/818/2008 and SFRH/BSAB/913/2009 sabbatical grants

    Bond of reinforcing bars to steel fiber reinforced concrete

    Full text link
    Steel fiber reinforced concrete (SFRC) has been increasingly used during recent years. Regarding bond of rebars to concrete, fibers provide passive confinement and improve bond capacity in terms of bond strength and, more importantly, toughness. An extensive experimental programme has been carried out, and SFRC specimens with embedded rebars have been subjected to the Pull Out Test to obtain the bond stress slip curves, retaining the bond strength and the area under the curve as measures of the bond capacity of concrete. The following parameters were considered: concrete compressive strength (30-50 MPa), rebar diameter (8-20 mm), concrete cover (between 30 mm and 5 times rebar diameter), fiber content (up to 70 kg/m(3)), and the slenderness and length of the steel fibers used. Predictive equations have been obtained to relate the experimental results to the factors considered, and the trends observed have been analyzed and discussed. (C) 2015 Elsevier Ltd. All rights reserved.The authors of this work wish to thank both the Research Bureau of the Spanish Ministry of Science and Innovation for the funding of the projects 'BIA 2009-12722' and 'BIA 2012-35776-AR', this research being a part thereof.GarcĂ­a Taengua, EJ.; MartĂ­ Vargas, JR.; Serna Ros, P. (2016). Bond of reinforcing bars to steel fiber reinforced concrete. Construction and Building Materials. 105:275-284. https://doi.org/10.1016/j.conbuildmat.2015.12.044S27528410

    Fiber-reinforcement and its effects on the mechanical properties of high-workability concretes manufactured with slag as aggregate and binder

    Get PDF
    The feasibility of manufacturing fiber-reinforced concretes of high workability through additions of high volumes of electric arc furnace steel slag is evaluated in this paper, using sustainable binders with ground granulated blast furnace slag and ladle furnace slag as a supplementary cementitious material. An extensive experimental plan is developed to test four (self-compacting and pumpable) concrete mixtures, some reinforced with 0.5% vol. of (metallic or synthetic) fibers, in both the fresh and the hardened state. Very specific mechanical aspects are examined, such as the evaluation of both longitudinal and transversal stress-strain compressive behavior, and the assessment of direct tensile strength through the “dog-bone” test. The results of testing this sustainable concrete design yielded suitable mechanical strengths, and good toughness, ductility and impact strength, among other properties. Good adhesion between the fibers and the cementitious matrix was also evident from the fiber pull-out test results. Finally, the overall results confirmed that the use of electric arc furnace steel slag can make a real contribution to construction-sector sustainability and that the mechanical behavior of these novel concretes meets the basic design requirements for use in real structures.Spanish Ministries MCI, AEI, EU and ERDF [RTI2018-097079-B-C31; 10.13039/501100011033; FPU17/03374]; the Junta de Castilla y León (Regional Government) and ERDF [UIC-231, BU119P17]; the Basque Government research group [IT1314-19]; Youth Employment Initiative (JCyL) and ESF [UBU05B_1274]; the University of Burgos [Y135.GI] and the University of the Basque Country [PPGA20/26]. Likewise, our thanks to CHRYSO and HORMOR for supplying the materials used in this research
    • 

    corecore