224 research outputs found

    Discrete/finite element modelling of rock cutting with a TBM disc cutter

    Get PDF
    The final publication is available at Springer via http://dx.doi.org/10.1007/s00603-016-1133-7This paper presents advanced computer simulation of rock cutting process typical for excavation works in civil engineering. Theoretical formulation of the hybrid discrete/finite element model has been presented. The discrete and finite element methods have been used in different subdomains of a rock sample according to expected material behaviour, the part which is fractured and damaged during cutting is discretized with the discrete elements while the other part is treated as a continuous body and it is modelled using the finite element method. In this way, an optimum model is created, enabling a proper representation of the physical phenomena during cutting and efficient numerical computation. The model has been applied to simulation of the laboratory test of rock cutting with a single TBM (tunnel boring machine) disc cutter. The micromechanical parameters have been determined using the dimensionless relationships between micro- and macroscopic parameters. A number of numerical simulations of the LCM test in the unrelieved and relieved cutting modes have been performed. Numerical results have been compared with available data from in-situ measurements in a real TBM as well as with the theoretical predictions showing quite a good agreement. The numerical model has provided a new insight into the cutting mechanism enabling us to investigate the stress and pressure distribution at the tool–rock interaction. Sensitivity analysis of rock cutting performed for different parameters including disc geometry, cutting velocity, disc penetration and spacing has shown that the presented numerical model is a suitable tool for the design and optimization of rock cutting process.Peer ReviewedPostprint (published version

    Advances in the development of the discrete element method for excavation processes

    Get PDF
    This work presents new developments of the discrete element method improving e ciency and accuracy of modelling of rock-like materials, especially in excavation processes.Postprint (published version

    Comparative study of different discrete element models and evaluation of equivalent micromechanical parameters

    Get PDF
    Comparative studies of different discrete element models of a rock-type material are presented. The discrete element formulation employs spherical particles with the cohesive interaction model combining linear elastic behaviour with brittle failure. Numerical studies consisted in simulation of the uniaxial compression test. Two cylindrical specimens with particle size distributions yielding different degree of heterogeneity have been used. Macroscopic response produced by different discrete element models has been compared. The main difference between the compared models consists in the evaluation of micromechanical constitutive parameters. Two approaches are compared. In the first approach, the contact stiffness and strength parameters depend on the local particle size, while in the second approach, global uniform contact parameters are assumed for all the contacting pairs in function of average geometric measures characterizing the particle assembly. The size dependent contact parameters are calculated as functions of geometric parameters characterizing each contacting particle pair. As geometric scaling parameters, the arithmetic and harmonic means, as well as the minimum of the radii of two contacting particles are considered. Two different models with size dependent contact parameters are formulated. The performance of these models is compared with that of the discrete element model with global uniform contact parameters. Equivalence between the models with size dependent and uniform contact parameters has been checked. In search of this equivalence, different methods of evaluation of global uniform parameters have been studied. The contact stiffness has been evaluated in terms of the average radius of the particle assembly or in terms of the averages of the arithmetic and harmonic means of the contact pair radii, the geometric parameters used in the evaluation of the contact stiffness in the size-dependent models. The uniform contact strengths have been determined as functions of the averages of radii squares, squares of arithmetic radii means or squares of minimum radii of the contacting pairs. For the more homogenous specimen, the models with local size dependent parameters and models with global uniform parameters give similar response. The models with uniform parameters evaluated according to the averages of the geometric parameters used in the evaluation of local parameters ensure better agreement with the respective models with size-dependent parameters than the models with uniform parameters evaluated according to the particle radii. Simulations using the more heterogenous specimen reveal differences between the considered models. There are significant differences in stress–strain curves as well as in the failure pattern. The models with local size-dependent parameters are more sensitive to the change of heterogeneity than the model with global uniform parameters.Peer ReviewedPostprint (published version

    Modelling and simulation of the effect of blast loading on structures using an adaptive blending of discrete and finite element methods

    Get PDF
    We present a new computational model for predicting the effect of blast loading on structures. The model is based in the adaptive coupling of the finite element method (FEM) and the discrete element method (DEM) for the accurate reproduction of multifracturing and failure of structures under blast loading. In the paper we briefly describe the basis of the coupled DEM/FEM technology and demonstrate its efficiency in its application to the study of the effect of blast loading on a masonry wall, a masonry tunnel and a double curvature dam.Postprint (published version

    Transcranial static magnetic stimulation reduces seizures in a mouse model of Dravet syndrome

    Get PDF
    [Abstract] Dravet syndrome is a rare form of severe genetic epilepsy characterized by recurrent and long-lasting seizures. It appears around the first year of life, with a quick evolution toward an increase in the frequency of the seizures, accompanied by a delay in motor and cognitive development, and does not respond well to antiepileptic medication. Most patients carry a mutation in the gene SCN1A encoding the α subunit of the voltage-gated sodium channel Nav1.1, resulting in hyperexcitability of neural circuits and seizure onset. In this work, we applied transcranial static magnetic stimulation (tSMS), a non-invasive, safe, easy-to-use and affordable neuromodulatory tool that reduces neural excitability in a mouse model of Dravet syndrome. We demonstrate that tSMS dramatically reduced the number of crises. Furthermore, crises recorded in the presence of the tSMS were shorter and less intense than in the sham condition. Since tSMS has demonstrated its efficacy at reducing cortical excitability in humans without showing unwanted side effects, in an attempt to anticipate a possible use of tSMS for Dravet Syndrome patients, we performed a numerical simulation in which the magnetic field generated by the magnet was modeled to estimate the magnetic field intensity reached in the cerebral cortex, which could help to design stimulation strategies in these patients. Our results provide a proof of concept for nonpharmacological treatment of Dravet syndrome, which opens the door to the design of new protocols for treatment.Instituto de salud Carlos III; PI21/00151Xunta de Galicia; ED431C 2022/05 (CR)Ministerio de Ciencia e Innovacion (España); PID2019-108250RJ-10

    Impact of footwear and foot deformities in patients with Parkinson?s disease: A case-series study

    Get PDF
    Background: Parkinson's disease (PD) is a common and complex neurological problem. Gait abnormalities are frequent in PD patients, and this increases the risk of falls. However, little is known about foot deformities and footwear in this vulnerable population. Here we investigate whether patients with PD use an appropriate shoe size and know if they have foot deformities or alterations. Methodology: A study of a series of observational descriptive cases in a convenience sample (n = 53 patients) diagnosed with Parkinson's disease. One trained investigator evaluated foot and ankle health. The footwear and foot measurements were obtained using a Brannock device. Results: The podiatric examination and footwear examination detected a high presence of podiatric pathologies and inappropriate footwear. This has a negative impact on the quality of life of these patients. Conclusions: This research detected an elevated number of people with foot deformities or alterations. Moreover, a high proportion of participants with PD wear inadequate footwear (in length, width, or both)

    Vasomotion and Neurovascular Coupling in the Visual Thalamus In Vivo

    Get PDF
    Spontaneous contraction and relaxation of arteries (and in some instances venules) has been termed vasomotion and has been observed in an extensive variety of tissues and species. However, its functions and underlying mechanisms are still under discussion. We demonstrate that in vivo spectrophotometry, measured simultaneously with extracellular recordings at the same locations in the visual thalamus of the cat, reveals vasomotion, measured as an oscillation (0.14hz) in the recorded oxyhemoglobin (OxyHb) signal, which appears spontaneously in the microcirculation and can last for periods of hours. During some non-oscillatory periods, maintained sensory stimulation evokes vasomotion lasting ∼30s, resembling an adaptive vascular phenomenon. This oscillation in the oxyhaemoblobin signal is sensitive to pharmacological manipulation: it is inducible by chloralose anaesthesia and it can be temporarily blocked by systemic administration of adrenaline or acetylcholine (ACh). During these oscillatory periods, neurovascular coupling (i.e. the relationship between local neural activity and the rate of blood supply to that location) appears significantly altered. This raises important questions with regard to the interpretation of results from studies currently dependent upon a linear relationship between neural activity and blood flow, such as neuroimaging

    Cortical Modulation of the Transient Visual Response at Thalamic Level: A TMS Study

    Get PDF
    The transient visual response of feline dorsal lateral geniculate nucleus (dLGN) cells was studied under control conditions and during the application of repetitive transcranial magnetic stimulation at 1 Hz (rTMS@1Hz) on the primary visual cortex (V1). The results show that rTMS@1Hz modulates the firing mode of Y cells, inducing an increase in burst spikes and a decrease in tonic firing. On the other hand, rTMS@1Hz modifies the spatiotemporal characteristics of receptive fields of X cells, inducing a delay and a decrease of the peak response, and a change of the surround/center amplitude ratio of RF profiles. These results indicate that V1 controls the activity of the visual thalamus in a different way in the X and Y pathways, and that this feedback control is consistent with functional roles associated with each cell type

    Middle ear microbiome differences in indigenous Filipinos with chronic otitis media due to a duplication in the A2ML1 gene

    Get PDF
    Middle ear microbial profiles of indigenous Filipinos with chronic otitis media. All panels compare carriers with non-carriers of the A2ML1 duplication variant. Panel description: (A) ι-diversity by observed OTUs; (B) ι-diversity by the Shannon diversity index; (C) β-diversity from unweighted UniFrac principal coordinate analysis; (D) β-diversity from weighted UniFrac principal coordinate analysis. (PDF 1019 kb

    Mild cognitive impairment is associated with poor physical function but not bone structure or density in late adulthood:Findings from the Hertfordshire Cohort Study

    Get PDF
    Mini Abstract This study investigated the association between mild cognitive impairment (MCI) and physical function and bone health in older adults. MCI was associated with poor physical performance but not bone mineral density or bone microarchitecture. Abstract Purpose: Cross-sectional study to investigate the association between mild cognitive impairment (MCI) and physical performance, and bone health, in a community-dwelling cohort of older adults. Methods: Cognitive function of 222 men and 221 women (mean age 75.5 and 75.8 years in men and women, respectively) was assessed by the Strawbridge questionnaire and Mini Mental State Exam (MMSE). Participants underwent dual-energy x-ray absorptiometry (DXA), peripheral-quantitative computed tomography (pQCT) and high-resolution peripheral-quantitative computed tomography (HR-pQCT) scans to assess their bone density, strength and microarchitecture. Their physical function was assessed and a physical performance (PP) score was recorded. Results: 11.8% of women and 8.1% of men in the study were cognitive impaired on the MMSE (score<24). 24% of women were deemed cognitively impaired on the Strawbridge questionnaire, compared to 22.3% of men. Cognitive impairment on the Strawbridge questionnaire was associated with poorer physical performance score in men but not women in the unadjusted analysis. MMSE <24 was strongly associated with the risk of low physical performance in men (OR 12.9, 95% CI 1.67, 99.8, p=0.01) Higher MMSE score was associated with better physical performance in both sexes. Poorer cognitive function, whether assessed by the Strawbridge questionnaire, or by MMSE score, was not associated with bone density, shape or microarchitecture, in either sex. Conclusion: MCI in older adults was associated with poor physical performance, but not bone density, shape or microarchitecture
    corecore