55 research outputs found

    High throughput simultaneous assay of atenolol and chlortalidone in combined dose tablets by liquid chromatography and capillary zone electrophoresis

    Get PDF
    New fast liquid chromatographic and capillary zone electrophoresis methods were developed and validated for simultaneous determination of atenolol and chlortalidone in combined dose tablets. The reversed phase HPLC method was carried out on a CN LiChrosorb® (125 x 4 mm, 5 μm) column. The CZE method was carried out on an uncoated fused-silica capillary of 30 cm x 75 μm i.d. with 25 mmol L-1 sodium tetraborate, pH 9.4. The total analysis time was <6 and <2.5 min for HPLC and CZE methods, respectively. Both methods can be used for stability studies as well.Colegio de Farmacéuticos de la Provincia de Buenos Aire

    Prevention of hypertension in patients with pre-hypertension: protocol for the PREVER-prevention trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Blood pressure (BP) within pre-hypertensive levels confers higher cardiovascular risk and is an intermediate stage for full hypertension, which develops in an annual rate of 7 out of 100 individuals with 40 to 50 years of age. Non-drug interventions to prevent hypertension have had low effectiveness. In individuals with previous cardiovascular disease or diabetes, the use of BP-lowering agents reduces the incidence of major cardiovascular events. In the absence of higher baseline risk, the use of BP agents reduces the incidence of hypertension. The PREVER-prevention trial aims to investigate the efficacy, safety and feasibility of a population-based intervention to prevent the incidence of hypertension and the development of target-organ damage.</p> <p>Methods</p> <p>This is a randomized, double-blind, placebo-controlled clinical trial, with participants aged 30 to 70 years, with pre-hypertension. The trial arms will be chlorthalidone 12.5 mg plus amiloride 2.5 mg or identical placebo. The primary outcomes will be the incidence of hypertension, adverse events and development or worsening of microalbuminuria and of left ventricular hypertrophy in the EKG. The secondary outcomes will be fatal or non-fatal cardiovascular events: myocardial infarction, stroke, heart failure, evidence of new sub-clinical atherosclerosis, and sudden death. The study will last 18 months. The sample size was calculated on the basis of an incidence of hypertension of 14% in the control group, a size effect of 40%, power of 85% and P alpha of 5%, resulting in 625 participants per group. The project was approved by the Ethics committee of each participating institution.</p> <p>Discussion</p> <p>The early use of blood pressure-lowering drugs, particularly diuretics, which act on the main mechanism of blood pressure rising with age, may prevent cardiovascular events and the incidence of hypertension in individuals with hypertension. If this intervention shows to be effective and safe in a population-based perspective, it could be the basis for an innovative public health program to prevent hypertension in Brazil.</p> <p>Trial Registration</p> <p>Clinical Trials <a href="http://www.clinicaltrials.gov/ct2/show/NCT00970931">NCT00970931</a>.</p

    Thrombus Migration Paradox in Patients With Acute Ischemic Stroke

    Get PDF
    Background and Purpose- The location of the thrombus as observed on first digital subtraction angiography during endovascular treatment may differ from the initial observation on initial noninvasive imaging. We studied the incidence of thrombus dynamics, its impact on patient outcomes, and its association with intravenous thrombolytics. Methods- We included patients from the MR CLEAN registry (Multicenter Randomized Clinical Trial of Endovascular Treatment of Acute Ischemic Stroke) with an initial target occlusion on computed tomography angiography located in the intracranial internal carotid artery, M1, or M2. The conventional angiography target occlusion was defined during endovascular treatment. Thrombus dynamics were classified as growth, stability, migration, and resolution. The primary outcome was functional outcome at 90 days (modified Rankin Scale). The secondary outcomes were successful and complete reperfusion (extended treatment in cerebral infarction scores of 2b-3 and 3, respectively). Results- The analysis included 1349 patients. Thrombus migration occurred in 302 (22%) patients, thrombus growth in 87 (6%), and thrombus resolution in 39 (3%). Intravenous treatment with alteplase was associated with more thrombus migration (adjusted odds ratio, 2.01; CI, 1.29-3.11) and thrombus resolution (adjusted odds ratio, 1.85; CI, 1.22-2.80). Thrombus migration was associated with a lower chance of complete reperfusion (adjusted odds ratio, 0.57; CI, 0.42-0.78) and successful reperfusion (adjusted odds ratio, 0.74; CI, 0.55-0.99). In the subgroup of patients with M1 initial target occlusion, thrombus migration was associated with better functional outcome (adjusted common odds ratio, 1.49; CI, 1.02-2.17), and there was a trend towards better functional outcome in patients with thrombus resolution (adjusted common odds ratio, 2.23; CI, 0.93-5.37). Conclusions- In patients with acute ischemic stroke, thrombus location regularly changes between computed tomography angiography and digital subtraction angiography. Administration of intravenous alteplase increases the chance of thrombus migration and resolution. Thrombus migration is associated with better functional outcome but reduces the rate of complete reperfusion

    ATLANTIC-CAMTRAPS: a dataset of medium and large terrestrial mammal communities in the Atlantic Forest of South America

    Get PDF
    Our understanding of mammal ecology has always been hindered by the difficulties of observing species in closed tropical forests. Camera trapping has become a major advance for monitoring terrestrial mammals in biodiversity rich ecosystems. Here we compiled one of the largest datasets of inventories of terrestrial mammal communities for the Neotropical region based on camera trapping studies. The dataset comprises 170 surveys of medium to large terrestrial mammals using camera traps conducted in 144 areas by 74 studies, covering six vegetation types of tropical and subtropical Atlantic Forest of South America (Brazil and Argentina), and present data on species composition and richness. The complete dataset comprises 53,438 independent records of 83 species of mammals, includes 10 species of marsupials, 15 rodents, 20 carnivores, eight ungulates and six armadillos. Species richness averaged 13 species (±6.07 SD) per site. Only six species occurred in more than 50% of the sites: the domestic dog Canis familiaris, crab-eating fox Cerdocyon thous, tayra Eira barbara, south American coati Nasua nasua, crab-eating raccoon Procyon cancrivorus and the nine-banded armadillo Dasypus novemcinctus. The information contained in this dataset can be used to understand macroecological patterns of biodiversity, community, and population structure, but also to evaluate the ecological consequences of fragmentation, defaunation, and trophic interactions. © 2017 by the Ecological Society of Americ

    Diretrizes Brasileiras de Medidas da Pressão Arterial Dentro e Fora do Consultório – 2023

    Get PDF
    Hypertension is one of the primary modifiable risk factors for morbidity and mortality worldwide, being a major risk factor for coronary artery disease, stroke, and kidney failure. Furthermore, it is highly prevalent, affecting more than one-third of the global population. Blood pressure measurement is a MANDATORY procedure in any medical care setting and is carried out by various healthcare professionals. However, it is still commonly performed without the necessary technical care. Since the diagnosis relies on blood pressure measurement, it is clear how important it is to handle the techniques, methods, and equipment used in its execution with care. It should be emphasized that once the diagnosis is made, all short-term, medium-term, and long-term investigations and treatments are based on the results of blood pressure measurement. Therefore, improper techniques and/or equipment can lead to incorrect diagnoses, either underestimating or overestimating values, resulting in inappropriate actions and significant health and economic losses for individuals and nations. Once the correct diagnosis is made, as knowledge of the importance of proper treatment advances, with the adoption of more detailed normal values and careful treatment objectives towards achieving stricter blood pressure goals, the importance of precision in blood pressure measurement is also reinforced. Blood pressure measurement (described below) is usually performed using the traditional method, the so-called casual or office measurement. Over time, alternatives have been added to it, through the use of semi-automatic or automatic devices by the patients themselves, in waiting rooms or outside the office, in their own homes, or in public spaces. A step further was taken with the use of semi-automatic devices equipped with memory that allow sequential measurements outside the office (ABPM; or HBPM) and other automatic devices that allow programmed measurements over longer periods (HBPM). Some aspects of blood pressure measurement can interfere with obtaining reliable results and, consequently, cause harm in decision-making. These include the importance of using average values, the variation in blood pressure during the day, and short-term variability. These aspects have encouraged the performance of a greater number of measurements in various situations, and different guidelines have advocated the use of equipment that promotes these actions. Devices that perform HBPM or ABPM, which, in addition to allowing greater precision, when used together, detect white coat hypertension (WCH), masked hypertension (MH), sleep blood pressure alterations, and resistant hypertension (RHT) (defined in Chapter 2 of this guideline), are gaining more and more importance. Taking these details into account, we must emphasize that information related to diagnosis, classification, and goal setting is still based on office blood pressure measurement, and for this reason, all attention must be given to the proper execution of this procedure.La hipertensión arterial (HTA) es uno de los principales factores de riesgo modificables para la morbilidad y mortalidad en todo el mundo, siendo uno de los mayores factores de riesgo para la enfermedad de las arterias coronarias, el accidente cerebrovascular (ACV) y la insuficiencia renal. Además, es altamente prevalente y afecta a más de un tercio de la población mundial. La medición de la presión arterial (PA) es un procedimiento OBLIGATORIO en cualquier atención médica o realizado por diferentes profesionales de la salud. Sin embargo, todavía se realiza comúnmente sin los cuidados técnicos necesarios. Dado que el diagnóstico se basa en la medición de la PA, es claro el cuidado que debe haber con las técnicas, los métodos y los equipos utilizados en su realización. Debemos enfatizar que una vez realizado el diagnóstico, todas las investigaciones y tratamientos a corto, mediano y largo plazo se basan en los resultados de la medición de la PA. Por lo tanto, las técnicas y/o equipos inadecuados pueden llevar a diagnósticos incorrectos, subestimando o sobreestimando valores y resultando en conductas inadecuadas y pérdidas significativas para la salud y la economía de las personas y las naciones. Una vez realizado el diagnóstico correcto, a medida que avanza el conocimiento sobre la importancia del tratamiento adecuado, con la adopción de valores de normalidad más detallados y objetivos de tratamiento más cuidadosos hacia metas de PA más estrictas, también se refuerza la importancia de la precisión en la medición de la PA. La medición de la PA (descrita a continuación) generalmente se realiza mediante el método tradicional, la llamada medición casual o de consultorio. Con el tiempo, se han agregado alternativas a través del uso de dispositivos semiautomáticos o automáticos por parte del propio paciente, en salas de espera o fuera del consultorio, en su propia residencia o en espacios públicos. Se dio un paso más con el uso de dispositivos semiautomáticos equipados con memoria que permiten mediciones secuenciales fuera del consultorio (AMPA; o MRPA) y otros automáticos que permiten mediciones programadas durante períodos más largos (MAPA). Algunos aspectos en la medición de la PA pueden interferir en la obtención de resultados confiables y, en consecuencia, causar daños en las decisiones a tomar. Estos incluyen la importancia de usar valores promedio, la variación de la PA durante el día y la variabilidad a corto plazo. Estos aspectos han alentado la realización de un mayor número de mediciones en diversas situaciones, y diferentes pautas han abogado por el uso de equipos que promuevan estas acciones. Los dispositivos que realizan MRPA o MAPA, que además de permitir una mayor precisión, cuando se usan juntos, detectan la hipertensión de bata blanca (HBB), la hipertensión enmascarada (HM), las alteraciones de la PA durante el sueño y la hipertensión resistente (HR) (definida en el Capítulo 2 de esta guía), están ganando cada vez más importancia. Teniendo en cuenta estos detalles, debemos enfatizar que la información relacionada con el diagnóstico, la clasificación y el establecimiento de objetivos todavía se basa en la medición de la presión arterial en el consultorio, y por esta razón, se debe prestar toda la atención a la ejecución adecuada de este procedimiento.A hipertensão arterial (HA) é um dos principais fatores de risco modificáveis para morbidade e mortalidade em todo o mundo, sendo um dos maiores fatores de risco para doença arterial coronária, acidente vascular cerebral (AVC) e insuficiência renal. Além disso, é altamente prevalente e atinge mais de um terço da população mundial. A medida da PA é procedimento OBRIGATÓRIO em qualquer atendimento médico ou realizado por diferentes profissionais de saúde. Contudo, ainda é comumente realizada sem os cuidados técnicos necessários. Como o diagnóstico se baseia na medida da PA, fica claro o cuidado que deve haver com as técnicas, os métodos e os equipamentos utilizados na sua realização. Deve-se reforçar que, feito o diagnóstico, toda a investigação e os tratamentos de curto, médio e longo prazos são feitos com base nos resultados da medida da PA. Assim, técnicas e/ou equipamentos inadequados podem levar a diagnósticos incorretos, tanto subestimando quanto superestimando valores e levando a condutas inadequadas e grandes prejuízos à saúde e à economia das pessoas e das nações. Uma vez feito o diagnóstico correto, na medida em que avança o conhecimento da importância do tratamento adequado, com a adoção de valores de normalidade mais detalhados e com objetivos de tratamento mais cuidadosos no sentido do alcance de metas de PA mais rigorosas, fica também reforçada a importância da precisão na medida da PA. A medida da PA (descrita a seguir) é habitualmente feita pelo método tradicional, a assim chamada medida casual ou de consultório. Ao longo do tempo, foram agregadas alternativas a ela, mediante o uso de equipamentos semiautomáticos ou automáticos pelo próprio paciente, nas salas de espera ou fora do consultório, em sua própria residência ou em espaços públicos. Um passo adiante foi dado com o uso de equipamentos semiautomáticos providos de memória que permitem medidas sequenciais fora do consultório (AMPA; ou MRPA) e outros automáticos que permitem medidas programadas por períodos mais prolongados (MAPA). Alguns aspectos na medida da PA podem interferir na obtenção de resultados fidedignos e, consequentemente, causar prejuízo nas condutas a serem tomadas. Entre eles, estão: a importância de serem utilizados valores médios, a variação da PA durante o dia e a variabilidade a curto prazo. Esses aspectos têm estimulado a realização de maior número de medidas em diversas situações, e as diferentes diretrizes têm preconizado o uso de equipamentos que favoreçam essas ações. Ganham cada vez mais espaço os equipamentos que realizam MRPA ou MAPA, que, além de permitirem maior precisão, se empregados em conjunto, detectam a HA do avental branco (HAB), HA mascarada (HM), alterações da PA no sono e HA resistente (HAR) (definidos no Capítulo 2 desta diretriz). Resguardados esses detalhes, devemos ressaltar que as informações relacionadas a diagnóstico, classificação e estabelecimento de metas ainda são baseadas na medida da PA de consultório e, por esse motivo, toda a atenção deve ser dada à realização desse procedimento

    Updated cardiovascular prevention guideline of the Brazilian Society of Cardiology: 2019

    Get PDF
    Sem informação113478788
    corecore