4,206 research outputs found

    Large-area submillimeter resolution CdZnTe strip detector for astronomy

    Get PDF
    We report the first performance measurements of a sub-millimeter CdZnTe strip detector developed as a prototype for space-borne astronomical instruments. Strip detector arrays can be used to provide two-dimensional position resolution with fewer electronic channels than pixellated arrays. Arrays of this type and other candidate technologies are under investigation for the position-sensitive backplane detector for a coded-aperture telescope operating in the range of 30 - 300 keV. The prototype is a 1.4 mm thick, 64 multiplied by 64 stripe CdZnTe array of 0.375 mm pitch in both dimensions, approximately one square inch of sensitive area. Pulse height spectra in both single and orthogonal stripe coincidence mode were recorded at several energies. The results are compared to slab- and pixel-geometry detector spectra. The room-temperature energy resolution is less than 10 keV (FWHM) for 122 keV photons with a peak-to-valley ratio greater than 5:1. The response to photons with energies up to 662 keV appears to be considerably improved relative to that of previously reported slab and pixel detectors. We also show that strip detectors can yield spatial and energy resolutions similar to those of pixellated arrays with the same dimensions. Electrostatic effects on the pulse heights, read-out circuit complexity, and issues related to design of space borne instruments are also discussed

    Factorial aerobic scope is independent of temperature and primarily modulated by heart rate in exercising Murray Cod (Maccullochella peelii peelii)

    Get PDF
    Several previous reports, often from studies utilising heavily instrumented animals, have indicated that for teleosts, the increase in cardiac output ( ) during exercise is mainly the result of an increase in cardiac stroke volume (VS) rather than in heart rate (fH). More recently, this contention has been questioned following studies on animals carrying less instrumentation, though the debate continues. In an attempt to shed more light on the situation, we examined the heart rates and oxygen consumption rates ( ; normalised to a mass of 1 kg, given as ) of six Murray cod (Maccullochella peelii peelii; kg) equipped with implanted fH and body temperature data loggers. Data were determined during exposure to varying temperatures and swimming speeds to encompass the majority of the biological scope of this species. An increase in body temperature (Tb) from 14°C to 29°C resulted in linear increases in (26.67-41.78 ÎŒmol min−1 kg−1) and fH (22.3-60.8 beats min−1) during routine exercise but a decrease in the oxygen pulse (the amount of oxygen extracted per heartbeat; 1.28-0.74 ÎŒmol beat−1 kg−1). During maximum exercise, the factorial increase in was calculated to be 3.7 at all temperatures and was the result of temperature-independent 2.2- and 1.7-fold increases in fH and oxygen pulse, respectively. The constant factorial increases in fH and oxygen pulse suggest that the cardiovascular variables of the Murray cod have temperature-independent maximum gains that contribute to maximal oxygen transport during exercise. At the expense of a larger factorial aerobic scope at an optimal temperature, as has been reported for species of salmon and trout, it is possible that the Murray cod has evolved a lower, but temperature-independent, factorial aerobic scope as an adaptation to the largely fluctuating and unpredictable thermal climate of southeastern Australia

    A mouse model for chronic pain-induced increase in ethanol consumption

    Get PDF
    Chronic pain conditions are often co-morbid with alcohol abuse. “Self-medication” with alcohol introduces a host of problems associated with the abuse of alcohol which over time has the potential of exacerbating the painful condition. Despite the prevalence of chronic pain being associated with alcohol abuse, rodent models which mimic the co-morbid conditions are lacking. In the present study, we model osteoarthritis (OA) in C57BL/6J mice by surgically destabilizing the medial meniscus (DMM). Sham operated mice served as controls. Thirteen weeks after surgery, DMM but not sham operated mice exhibited pronounced incapacitance of the surgically-manipulated hindlimb compared to the non-surgically manipulated hindlimb. At this time, the mice were exposed to the two-bottle ethanol choice, beginning with 2.5% with a gradual increasing to 20%. Compared to sham controls, DMM mice consumed more EtOH and preferred EtOH over water at the 20% EtOH concentration. Histological analysis verified that the DMM mice exhibited significant damage to the articular cartilage and osteophyte growth compared to sham controls and these measures of the severity of OA correlated with the amount of ethanol intake. Thus, the combination of the DMM model of OA with the enhanced two-bottle ethanol choice is a potential preclinical approach in mice by which the basis of the co-morbid association of alcohol abuse and chronic pain conditions can be explored

    Development of an orthogonal-stripe CdZnTe gamma radiation imaging spectrometer

    Get PDF
    We report performance measurements of a sub-millimeter resolution CdZnTe strip detector developed as a prototype for astronomical instruments operating with good efficiency in the 30-300 keV photon energy range. The prototype is a 1.4 mm thick, 64×64 contact stripe CdZnTe array of 0.375 mm pitch in both dimensions. Pulse height spectra were recorded in orthogonal-stripe coincidence mode which demonstrate room-temperature energy resolution \u3c10 keV (FWHM) for 122 keV photons with a peak-to-valley ratio \u3e5:1. Good response is also demonstrated at higher energies using a coplanar grid readout configuration. Spatial resolution capabilities finer than the stripe pitch are demonstrated. We present the image of a 133Ba source viewed through a collimator slit produced by a 4×4 stripe detector segment. Charge signals from electron and hole collecting contacts are also discussed

    Risk factors associated with detailed reproductive phenotypes in dairy and beef cows

    Get PDF
    peer-reviewedThis article was first published in animal, Volume 8, Issue 05, May 2014, pp 695-703, © The Animal Consortium 2014The objective of this study was to identify detailed fertility traits in dairy and beef cattle from transrectal ultrasonography records and quantify the associated risk factors. Data were available on 148 947 ultrasound observations of the reproductive tract from 75 949 cows in 843 Irish dairy and beef herds between March 2008 and October 2012. Traits generated included (1) cycling at time of examination, (2) cystic structures, (3) early ovulation, (4) embryo death and (5) uterine score; the latter was measured on a scale of 1 (good) to 4 (poor) characterising the tone of the uterine wall and fluid present in the uterus. After editing, 72 773 records from 44 415 dairy and beef cows in 643 herds remained. Factors associated with the logit of the probability of a positive outcome for each of the binary fertility traits were determined using generalised estimating equations; linear mixed model analysis was used for the analysis of uterine score. The prevalence of cycling, cystic structures, early ovulation and embryo death was 84.75%, 3.87%, 7.47% and 3.84%, respectively. The occurrence of the uterine heath score of 1, 2, 3 and 4 was 70.63%, 19.75%, 8.36% and 1.26%, respectively. Cows in beef herds had a 0.51 odds (95% CI = 0.41 to 0.63, P<0.001) of cycling at the time of examination compared with cows in dairy herds; stage of lactation at the time of examination was the same in both herd types. Furthermore, cows in dairy herds had an inferior uterine score (indicating poorer tone and a greater quantity of uterine fluid present) compared with cows in beef herds. The likelihood of cycling at the time of examination increased with parity and stage of lactation, but was reduced in cows that had experienced dystocia in the previous calving. The presence of cystic structures on the ovaries increased with parity and stage of lactation. The likelihood of embryo/foetal death increased with parity and stage of lactation. Dystocia was not associated with the presence of cystic structures or embryo death. Uterine score improved with parity and stage of lactation, while cows that experienced dystocia in the previous calving had an inferior uterine score. Heterosis was the only factor associated with increased likelihood of early ovulation. The fertility traits identified, and the associated risk factors, provide useful information on the reproductive status of dairy and beef cows.Funding from the Department of Agriculture, Food and Marine Research Stimulus Fund (RSF 11/S/133) and the OptiMIR project is gratefully acknowledged

    Porosity detection in electron beam-melted Ti-6Al-4V using high-resolution neutron imaging and grating-based interferometry

    Get PDF
    © 2017, Springer International Publishing Switzerland. A high-resolution neutron tomography system and a grating-based interferometer are used to explore electron beam-melted titanium test objects. The high-resolution neutron tomography system (attenuation-based imaging) has a pixel size of 6.4 ”m, appropriate for detecting voids near 25 ”m over a (1.5 cm)3 volume. The neutron interferometer provides dark-field (small-angle scattering) images with a pixel size of 30 ”m. Moreover, the interferometer can be tuned to a scattering length, in this case, 1.97 ”m, with a field-of-view of (6 cm)3. The combination of high-resolution imaging with grating-based interferometry provides a way for nondestructive testing of defective titanium samples. A chimney-like pore structure was discovered in the attenuation and dark-field images along one face of an electron beam-melted (EBM) Ti-6Al-4V cube. Tomographic reconstructions of the titanium samples are utilized as a source for a binary volume and for skeletonization of the pores. The dark-field volume shows features with dimensions near and smaller than the interferometer auto-correlation scattering length

    Stearyl methacrylate-based polymers as crystal habit modifiers for triacylglycerols

    Get PDF
    © 2018 American Chemical Society. Triacrylglycerols (TAGs) are ubiquitous and naturally occurring fat molecules that can make materials with diverse textural, mechanical, and optical properties. These properties are intimately linked to their complex hierarchical crystal structures, which can be controlled by additives that interfere with crystallization. A series of semicrystalline, bottlebrush-like copolymers have been developed to modify TAG crystallization and influence crystal habit. Synthesized by reversible addition-fragmentation chain transfer (RAFT) polymerization, these copolymer additives combine crystalline poly(stearyl methacrylate) with amorphous poly(oleyl methacrylate) in either block or statistical architecture. Upon cooling mixtures of these copolymers with solutions of tristearin (SSS) in triolein (OOO), the polymeric additives affected SSS crystallization at multiple length-scales. Microscopy analysis revealed control over SSS crystal morphology indicative of crystal aggregation, while small and wide-angle X-ray diffraction (SAXD/WAXD) offered insight into the underlying mechanism of action. Analyzing the physical broadening of lamellar peaks suggested that the fraction of amorphous poly(oleyl methacrylate) controls the thickness of primary nanoplatelets, and crystal structures derived from WAXD showed that the less stable α- or ÎČâ€Č-polymorphs of SSS are stabilized by block or statistical copolymers, respectively. Exploiting these additives to simultaneously manipulate the packing of TAG molecules within lamellae, the size of primary crystallites, and the aggregation of crystallites could diversify fat material properties and supplement wide-ranging applications

    PD-1 Co-inhibitory and OX40 Co-stimulatory Crosstalk Regulates Helper T Cell Differentiation and Anti-Plasmodium Humoral Immunity

    Get PDF
    SummaryThe differentiation and protective capacity of Plasmodium-specific T cells are regulated by both positive and negative signals during malaria, but the molecular and cellular details remain poorly defined. Here we show that malaria patients and Plasmodium-infected rodents exhibit atypical expression of the co-stimulatory receptor OX40 on CD4 T cells and that therapeutic enhancement of OX40 signaling enhances helper CD4 T cell activity, humoral immunity, and parasite clearance in rodents. However, these beneficial effects of OX40 signaling are abrogated following coordinate blockade of PD-1 co-inhibitory pathways, which are also upregulated during malaria and associated with elevated parasitemia. Co-administration of biologics blocking PD-1 and promoting OX40 signaling induces excessive interferon-gamma that directly limits helper T cell-mediated support of humoral immunity and decreases parasite control. Our results show that targeting OX40 can enhance Plasmodium control and that crosstalk between co-inhibitory and co-stimulatory pathways in pathogen-specific CD4 T cells can impact pathogen clearance

    Proxima Centauri b is not a transiting exoplanet

    Full text link
    We report Spitzer Space Telescope observations during predicted transits of the exoplanet Proxima Centauri b. As the nearest terrestrial habitable-zone planet we will ever discover, any potential transit of Proxima b would place strong constraints on its radius, bulk density, and atmosphere. Subsequent transmission spectroscopy and secondary-eclipse measurements could then probe the atmospheric chemistry, physical processes, and orbit, including a search for biosignatures. However, our photometric results rule out planetary transits at the 200~ppm level at 4.5 Όm~{\mu}m, yielding a 3σ\sigma upper radius limit of 0.4~R_\rm{\oplus} (Earth radii). Previous claims of possible transits from optical ground- and space-based photometry were likely correlated noise in the data from Proxima Centauri's frequent flaring. Follow-up observations should focus on planetary radio emission, phase curves, and direct imaging. Our study indicates dramatically reduced stellar activity at near-to-mid infrared wavelengths, compared to the optical. Proxima b is an ideal target for space-based infrared telescopes, if their instruments can be configured to handle Proxima's brightness.Comment: 8 pages, 3 figures, 2 tables, accepted for publication in MNRA
    • 

    corecore