65 research outputs found

    Screening vaccine formulations for biological activity using fresh human whole blood.

    Get PDF
    Understanding the relevant biological activity of any pharmaceutical formulation destined for human use is crucial. For vaccine-based formulations, activity must reflect the expected immune response, while for non-vaccine therapeutic agents, such as monoclonal antibodies, a lack of immune response to the formulation is desired. During early formulation development, various biochemical and biophysical characteristics can be monitored in a high-throughput screening (HTS) format. However, it remains impractical and arguably unethical to screen samples in this way for immunological functionality in animal models. Furthermore, data for immunological functionality lag formulation design by months, making it cumbersome to relate back to formulations in real-time. It is also likely that animal testing may not accurately reflect the response in humans. For a more effective formulation screen, a human whole blood (hWB) approach can be used to assess immunological functionality. The functional activity relates directly to the human immune response to a complete formulation (adjuvant/antigen) and includes adjuvant response, antigen response, adjuvant-modulated antigen response, stability, and potentially safety. The following commentary discusses the hWB approach as a valuable new tool to de-risk manufacture, formulation design, and clinical progression

    Reversion of the ELISPOT test after treatment in Gambian tuberculosis cases

    Get PDF
    BACKGROUND: New tools are required to improve tuberculosis (TB) diagnosis and treatment, including enhanced ability to compare new treatment strategies. The ELISPOT assay uses Mycobacterium tuberculosis-specific antigens to produce a precise quantitative readout of the immune response to pathogen. We hypothesized that TB patients in The Gambia would have reduced ELISPOT counts after successful treatment. METHODS: We recruited Gambian adults with sputum smear and culture positive tuberculosis for ELISPOT assay and HIV test, and followed them up one year later to repeat testing and document treatment outcome. We used ESAT-6, CFP-10 and Purified Protein Derivative (PPD) as stimulatory antigens. We confirmed the reliability of our assay in 23 volunteers through 2 tests one week apart, comparing within and between subject variation. RESULTS: We performed an ELISPOT test at diagnosis and 12 months later in 89 patients. At recruitment, 70/85 HIV-negative patients (82%) were ESAT-6 or CFP-10 (EC) ELISPOT positive, 77 (90%) were PPD ELISPOT positive. Eighty-two cases (96%) successfully completed treatment: 44 (55%; p < 0.001) were EC ELISPOT negative at 12 months, 17 (21%; p = 0.051) were PPD ELISPOT negative. Sixty (73%) cured cases had a CFP-10 ELISPOT count decrease, 64 (78%) had an ESAT-6 ELISPOT count decrease, 58 (70%) had a PPD ELISPOT count decrease. There was a mean decline of 25, 44 and 47 SFU/2 × 10(5 )cells for CFP-10, ESAT-6 and PPD respectively (p < 0.001 for all). Three of 4 HIV positive patients were cured, all 3 underwent ELISPOT reversion; all 4 not cured subjects (3 HIV-negative, 1 HIV positive) were ESAT-6, CFP-10 and PPD ELISPOT positive at 12 months. CONCLUSION: Successful tuberculosis treatment is accompanied by a significant reduction in the M. tuberculosis-specific antigen ELISPOT count. The ELISPOT has potential as a proxy measure of TB treatment outcome. Further investigation into the decay kinetics of T-cells with treatment is warranted

    Safety and immunogenicity of the candidate tuberculosis vaccine MVA85A in West Africa.

    Get PDF
    BACKGROUND: Vaccination with a recombinant modified vaccinia Ankara expressing antigen 85A from Mycobacterium tuberculosis, MVA85A, induces high levels of cellular immune responses in UK volunteers. We assessed the safety and immunogenicity of this new vaccine in West African volunteers. METHODS AND FINDINGS: We vaccinated 21 healthy adult male subjects (11 BCG scar negative and 10 BCG scar positive) with MVA85A after screening for evidence of prior exposure to mycobacteria. We monitored them over six months, observing for clinical, haematological and biochemical adverse events, together with assessment of the vaccine induced cellular immune response using ELISPOT and flow cytometry. MVA85A was well tolerated with no significant adverse events. Mild local and systemic adverse events were consistent with previous UK trials. Marked immunogenicity was found whether individuals had a previous BCG scar or not. There was not enhanced immunogenicity in those with a BCG scar, and induced T cell responses were better maintained in apparently BCG-naïve Gambians than previously studied BCG-naïve UK vaccinees. Although responses were predominantly attributable to CD4+ T cells, we also identified antigen specific CD8+ T cell responses, in subjects who were HLA B-35 and in whom enough blood was available for more detailed immunological analysis. CONCLUSIONS: These data on the safety and immunogenicity of MVA85A in West Africa support its accelerated development as a promising booster vaccine for tuberculosis. TRIAL REGISTRATION: ClinicalTrials.gov NCT00423839

    Using ELISPOT to Expose False Positive Skin Test Conversion in Tuberculosis Contacts

    Get PDF
    BACKGROUND: Repeat tuberculin skin tests may be false positive due to boosting of waned immunity to past mycobacterial exposure. We evaluated whether an ELISPOT test could identify tuberculosis (TB) contacts with boosting of immunity to non-tuberculous mycobacterial exposure. METHODOLOGY/PRINCIPAL FINDINGS: We conducted tuberculin and ELISPOT tests in 1665 TB contacts: 799 were tuberculin test negative and were offered a repeat test after three months. Those with tuberculin test conversion had an ELISPOT, chest X-ray and sputum analysis if appropriate. We compared converters with non-converters, assessed the probability of each of four combinations of ELISPOT results over the two time points and estimated boosting with adjustment for ELISPOT sensitivity and specificity. 704 (72%) contacts had a repeat tuberculin test; 176 (25%) had test conversion, which increased with exposure to a case (p = 0.002), increasing age (p = 0.0006) and BCG scar (p = 0.06). 114 tuberculin test converters had ELISPOT results: 16(14%) were recruitment positive/follow-up positive, 9 (8%) positive/negative, 34 (30%) negative/positive, and 55 (48%) were negative/negative. There was a significant non-linear effect of age for ELISPOT results in skin test converters (p = 0.038). Estimates of boosting ranged from 32%–41% of skin test converters with increasing age. Three converters were diagnosed with TB, two had ELISPOT results: both were positive, including one at recruitment. CONCLUSIONS/SIGNIFICANCE: We estimate that approximately one third of tuberculin skin test conversion in Gambian TB case contacts is due to boosting of immunity to non-tuberculous mycobacterial exposure. Further longitudinal studies are required to confirm whether ELISPOT can reliably identify case contacts with tuberculin test conversion that would benefit most from prophylactic treatment

    Surprisingly High Specificity of the PPD Skin Test for M. tuberculosis Infection from Recent Exposure in The Gambia

    Get PDF
    BACKGROUND: Options for intervention against Mycobacterium tuberculosis infection are limited by the diagnostic tools available. The Purified Protein Derivative (PPD) skin test is thought to be non-specific, especially in tropical settings. We compared the PPD skin test with an ELISPOT test in The Gambia. METHODOLOGY/PRINCIPAL FINDINGS: Household contacts over six months of age of sputum smear positive TB cases and community controls were recruited. They underwent a PPD skin test and an ELISPOT test for the T cell response to PPD and ESAT-6/CFP10 antigens. Responsiveness to M. tuberculosis exposure was analysed according to sleeping proximity to an index case using logistic regression. 615 household contacts and 105 community controls were recruited. All three tests assessed increased significantly in positivity with increasing M. tuberculosis exposure, the PPD skin test most dramatically (OR 15.7; 95% CI 6.6–35.3). While the PPD skin test positivity continued to trend downwards in the community with increasing distance from a known case (61.9% to 14.3%), the PPD and ESAT-6/CFP-10 ELISPOT positivity did not. The PPD skin test was more in agreement with ESAT-6/CFP-10 ELISPOT (75%, p = 0.01) than the PPD ELISPOT (53%, p<0.0001). With increasing M. tuberculosis exposure, the proportion of ESAT-6/CFP-10 positive contacts who were PPD skin test positive increased (p<0.0001), and the proportion of ESAT-6/CFP-10 negative contacts that were PPD skin test negative decreased (p<0.0001); the converse did not occur. CONCLUSIONS/SIGNIFICANCE: The PPD skin test has surprisingly high specificity for M. tuberculosis infection from recent exposure in The Gambia. In this setting, anti-tuberculous prophylaxis in PPD skin test positive individuals should be revisited

    A methodological framework to distinguish spectrum effects from spectrum biases and to assess diagnostic and screening test accuracy for patient populations: Application to the Papanicolaou cervical cancer smear test

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>A spectrum effect was defined as differences in the sensitivity or specificity of a diagnostic test according to the patient's characteristics or disease features. A spectrum effect can lead to a spectrum bias when subgroup variations in sensitivity or specificity also affect the likelihood ratios and thus post-test probabilities. We propose and illustrate a methodological framework to distinguish spectrum effects from spectrum biases.</p> <p>Methods</p> <p>Data were collected for 1781 women having had a cervical smear test and colposcopy followed by biopsy if abnormalities were detected (the reference standard). Logistic models were constructed to evaluate both the sensitivity and specificity, and the likelihood ratios, of the test and to identify factors independently affecting the test's characteristics.</p> <p>Results</p> <p>For both tests, human papillomavirus test, study setting and age affected sensitivity or specificity of the smear test (spectrum effect), but only human papillomavirus test and study setting modified the likelihood ratios (spectrum bias) for clinical reading, whereas only human papillomavirus test and age modified the likelihood ratios (spectrum bias) for "optimized" interpretation.</p> <p>Conclusion</p> <p>Fitting sensitivity, specificity and likelihood ratios simultaneously allows the identification of covariates that independently affect diagnostic or screening test results and distinguishes spectrum effect from spectrum bias. We recommend this approach for the development of new tests, and for reporting test accuracy for different patient populations.</p

    The Lockman Hole project: LOFAR observations and spectral index properties of low-frequency radio sources

    Get PDF
    The Lockman Hole is a well-studied extragalactic field with extensive multi-band ancillary data covering a wide range in frequency, essential for characterizing the physical and evolutionary properties of the various source populations detected in deep radio fields (mainly star-forming galaxies and AGNs). In this paper, we present new 150-MHz observations carried out with the LOw-Frequency ARray (LOFAR), allowing us to explore a new spectral window for the faint radio source population. This 150-MHz image covers an area of 34.7 square degrees with a resolution of 18.6 × 14.7 arcsec and reaches an rms of 160 μJy beam1^-1 at the centre of the field. As expected for a low-frequency selected sample, the vast majority of sources exhibit steep spectra, with a median spectral index of α1501400=0.78±0.015\alpha _{150}^{1400}=-0.78\pm 0.015. The median spectral index becomes slightly flatter (increasing from α1501400=0.75)\alpha _{150}^{1400}=-0.75) with decreasing flux density down to S_1_5_0 ∼10 mJy before flattening out and remaining constant below this flux level. For a bright subset of the 150-MHz selected sample, we can trace the spectral properties down to lower frequencies using 60-MHz LOFAR observations, finding tentative evidence for sources to become flatter in spectrum between 60 and 150 MHz. Using the deep, multi-frequency data available in the Lockman Hole, we identify a sample of 100 ultra-steep-spectrum sources and 13 peaked-spectrum sources. We estimate that up to 21 per cent of these could have z > 4 and are candidate high-z radio galaxies, but further follow-up observations are required to confirm the physical nature of these objects

    Rare coding variants in PLCG2, ABI3, and TREM2 implicate microglial-mediated innate immunity in Alzheimer's disease

    Get PDF
    We identified rare coding variants associated with Alzheimer’s disease (AD) in a 3-stage case-control study of 85,133 subjects. In stage 1, 34,174 samples were genotyped using a whole-exome microarray. In stage 2, we tested associated variants (P<1×10-4) in 35,962 independent samples using de novo genotyping and imputed genotypes. In stage 3, an additional 14,997 samples were used to test the most significant stage 2 associations (P<5×10-8) using imputed genotypes. We observed 3 novel genome-wide significant (GWS) AD associated non-synonymous variants; a protective variant in PLCG2 (rs72824905/p.P522R, P=5.38×10-10, OR=0.68, MAFcases=0.0059, MAFcontrols=0.0093), a risk variant in ABI3 (rs616338/p.S209F, P=4.56×10-10, OR=1.43, MAFcases=0.011, MAFcontrols=0.008), and a novel GWS variant in TREM2 (rs143332484/p.R62H, P=1.55×10-14, OR=1.67, MAFcases=0.0143, MAFcontrols=0.0089), a known AD susceptibility gene. These protein-coding changes are in genes highly expressed in microglia and highlight an immune-related protein-protein interaction network enriched for previously identified AD risk genes. These genetic findings provide additional evidence that the microglia-mediated innate immune response contributes directly to AD development

    Multiorgan MRI findings after hospitalisation with COVID-19 in the UK (C-MORE): a prospective, multicentre, observational cohort study

    Get PDF
    Introduction: The multiorgan impact of moderate to severe coronavirus infections in the post-acute phase is still poorly understood. We aimed to evaluate the excess burden of multiorgan abnormalities after hospitalisation with COVID-19, evaluate their determinants, and explore associations with patient-related outcome measures. Methods: In a prospective, UK-wide, multicentre MRI follow-up study (C-MORE), adults (aged ≥18 years) discharged from hospital following COVID-19 who were included in Tier 2 of the Post-hospitalisation COVID-19 study (PHOSP-COVID) and contemporary controls with no evidence of previous COVID-19 (SARS-CoV-2 nucleocapsid antibody negative) underwent multiorgan MRI (lungs, heart, brain, liver, and kidneys) with quantitative and qualitative assessment of images and clinical adjudication when relevant. Individuals with end-stage renal failure or contraindications to MRI were excluded. Participants also underwent detailed recording of symptoms, and physiological and biochemical tests. The primary outcome was the excess burden of multiorgan abnormalities (two or more organs) relative to controls, with further adjustments for potential confounders. The C-MORE study is ongoing and is registered with ClinicalTrials.gov, NCT04510025. Findings: Of 2710 participants in Tier 2 of PHOSP-COVID, 531 were recruited across 13 UK-wide C-MORE sites. After exclusions, 259 C-MORE patients (mean age 57 years [SD 12]; 158 [61%] male and 101 [39%] female) who were discharged from hospital with PCR-confirmed or clinically diagnosed COVID-19 between March 1, 2020, and Nov 1, 2021, and 52 non-COVID-19 controls from the community (mean age 49 years [SD 14]; 30 [58%] male and 22 [42%] female) were included in the analysis. Patients were assessed at a median of 5·0 months (IQR 4·2–6·3) after hospital discharge. Compared with non-COVID-19 controls, patients were older, living with more obesity, and had more comorbidities. Multiorgan abnormalities on MRI were more frequent in patients than in controls (157 [61%] of 259 vs 14 [27%] of 52; p&lt;0·0001) and independently associated with COVID-19 status (odds ratio [OR] 2·9 [95% CI 1·5–5·8]; padjusted=0·0023) after adjusting for relevant confounders. Compared with controls, patients were more likely to have MRI evidence of lung abnormalities (p=0·0001; parenchymal abnormalities), brain abnormalities (p&lt;0·0001; more white matter hyperintensities and regional brain volume reduction), and kidney abnormalities (p=0·014; lower medullary T1 and loss of corticomedullary differentiation), whereas cardiac and liver MRI abnormalities were similar between patients and controls. Patients with multiorgan abnormalities were older (difference in mean age 7 years [95% CI 4–10]; mean age of 59·8 years [SD 11·7] with multiorgan abnormalities vs mean age of 52·8 years [11·9] without multiorgan abnormalities; p&lt;0·0001), more likely to have three or more comorbidities (OR 2·47 [1·32–4·82]; padjusted=0·0059), and more likely to have a more severe acute infection (acute CRP &gt;5mg/L, OR 3·55 [1·23–11·88]; padjusted=0·025) than those without multiorgan abnormalities. Presence of lung MRI abnormalities was associated with a two-fold higher risk of chest tightness, and multiorgan MRI abnormalities were associated with severe and very severe persistent physical and mental health impairment (PHOSP-COVID symptom clusters) after hospitalisation. Interpretation: After hospitalisation for COVID-19, people are at risk of multiorgan abnormalities in the medium term. Our findings emphasise the need for proactive multidisciplinary care pathways, with the potential for imaging to guide surveillance frequency and therapeutic stratification
    corecore