323 research outputs found
Preparation and photoacoustic analysis of cellular vehicles containing gold nanorods
Gold nanorods are attractive for a range of biomedical applications, such as the photothermal ablation and the photoacoustic imaging of cancer, thanks to their intense optical absorbance in the near-infrared window, low cytotoxicity and potential to home into tumors. However, their delivery to tumors still remains an issue. An innovative approach consists of the exploitation of the tropism of tumor-associated macrophages that may be loaded with gold nanorods in vitro. Here, we describe the preparation and the photoacoustic inspection of cellular vehicles containing gold nanorods. PEGylated gold nanorods are modified with quaternary ammonium compounds, in order to achieve a cationic profile. On contact with murine macrophages in ordinary Petri dishes, these particles are found to undergo massive uptake into endocytic vesicles. Then these cells are embedded in biopolymeric hydrogels, which are used to verify that the stability of photoacoustic conversion of the particles is retained in their inclusion into cellular vehicles. We are confident that these results may provide new inspiration for the development of novel strategies to deliver plasmonic particles to tumors
Characterization of a front-end electronics for the monitoring and control of hadrontherapy beams
Abstract An integrated 64-channel device for the read-out of parallel plate pixel and strip ionization detectors has been developed by the INFN and University of Torino. The detectors will be used for the monitoring and control of hadrontherapy beams. The ASIC has been designed in CMOS 0.8 μm technology and it is based on a current-to-frequency converter followed by a synchronous counter. In this paper, we present a detailed characterization of the device done with 113 chips
Incidence of X-rays exposure in spinal surgeries
Introducción: El control radioscópico intraoperatorio es una práctica cada vez más frecuente, que no está libre de eventos adversos para el personal de la salud. Objetivos: Conocer la tasa de uso de radioscopia en la cirugía vertebral, reconocer las medidas de control, evaluar la asimilación del cirujano a los elementos de protección y analizar los eventos adversos en estos profesionales.
Materiales y Métodos: Se envió, por correo electrónico, a cirujanos espinales, una encuesta de 17 preguntas de opciones múltiples. Resultados: Se recibieron 55 encuestas. El 87% se dedicaba a la columna, en más del 60% de sus prácticas. El arco en C es el método más utilizado para el control final, en forma pulsátil. Solo el 31% controla el tiempo real. El delantal plomado de una pieza es el método más utilizado, pero se desconoce cuándo se debe reemplazar. La mitad utiliza más de un elemento.
Siete casos de trastornos visuales, 5 patologías tiroideas, 3 dermatitis y 2 casos de infertilidad. Tres cirujanos fueron operados por nódulos tiroideos, cataratas o neoplasia. Conclusiones: El control radioscópico intraoperatorio es una práctica frecuente en la cirugía espinal. El delantal plomado de una pieza es el método más utilizado y, muchas veces, se lo combina, pero se desconoce cuándo se deben renovar los plomados. Uno de cada tres cirujanos presentaron las patologías evaluadas y 3, cirugías relacionadas.
Así queda en evidencia la protección y el control escasos que existen en los cirujanos especialistas, acompañados de una falta de protocolización que deja a la deriva este control.Background: Intraoperative radiographic control (IRC) is an increasingly common practice, but it causes certain adverse events for healthcare providers. Objectives: To measure the use of fluoroscopy in spinal surgery, recognize control measures, evaluate assimilation of protection elements by surgeons, and analyze adverse events for spinal surgeons. Materials and Methods: A survey of 17 multiple-choice questions was e-mailed to spinal surgeons. Results: 55 surveys were answered. More than 60% of surgeons were spinal surgeons. The C-arm is the most widely used machine for final control by pulsating X-rays. Real-time controls are carried out in 31% of cases. One-piece leaded aprons are the most commonly used method, but it is unknown when they should be replaced. Half of the respondents uses more than one protection element. There were seven cases of vision changes, 5 of thyroid disorders, 3 of dermatitis, and 2 of infertility. Three surgeons required surgery for thyroid nodules, cataracts or neoplasm.
Conclusions: IRC is a common practice in spinal surgery. One-piece leaded aprons are the most commonly used method and they are often combined with other elements, but it is not known when aprons must be replaced. One in 3 surgeons suffered from the studied conditions, and there were 3 related surgeries. Lack of adequate protection and control is a reality for specialist surgeons, together with a lack of protocols, making this an unregulated issue.Facultad de Ciencias Médica
Incidence of X-rays exposure in spinal surgeries
Introducción: El control radioscópico intraoperatorio es una práctica cada vez más frecuente, que no está libre de eventos adversos para el personal de la salud. Objetivos: Conocer la tasa de uso de radioscopia en la cirugía vertebral, reconocer las medidas de control, evaluar la asimilación del cirujano a los elementos de protección y analizar los eventos adversos en estos profesionales.
Materiales y Métodos: Se envió, por correo electrónico, a cirujanos espinales, una encuesta de 17 preguntas de opciones múltiples. Resultados: Se recibieron 55 encuestas. El 87% se dedicaba a la columna, en más del 60% de sus prácticas. El arco en C es el método más utilizado para el control final, en forma pulsátil. Solo el 31% controla el tiempo real. El delantal plomado de una pieza es el método más utilizado, pero se desconoce cuándo se debe reemplazar. La mitad utiliza más de un elemento.
Siete casos de trastornos visuales, 5 patologías tiroideas, 3 dermatitis y 2 casos de infertilidad. Tres cirujanos fueron operados por nódulos tiroideos, cataratas o neoplasia. Conclusiones: El control radioscópico intraoperatorio es una práctica frecuente en la cirugía espinal. El delantal plomado de una pieza es el método más utilizado y, muchas veces, se lo combina, pero se desconoce cuándo se deben renovar los plomados. Uno de cada tres cirujanos presentaron las patologías evaluadas y 3, cirugías relacionadas.
Así queda en evidencia la protección y el control escasos que existen en los cirujanos especialistas, acompañados de una falta de protocolización que deja a la deriva este control.Background: Intraoperative radiographic control (IRC) is an increasingly common practice, but it causes certain adverse events for healthcare providers. Objectives: To measure the use of fluoroscopy in spinal surgery, recognize control measures, evaluate assimilation of protection elements by surgeons, and analyze adverse events for spinal surgeons. Materials and Methods: A survey of 17 multiple-choice questions was e-mailed to spinal surgeons. Results: 55 surveys were answered. More than 60% of surgeons were spinal surgeons. The C-arm is the most widely used machine for final control by pulsating X-rays. Real-time controls are carried out in 31% of cases. One-piece leaded aprons are the most commonly used method, but it is unknown when they should be replaced. Half of the respondents uses more than one protection element. There were seven cases of vision changes, 5 of thyroid disorders, 3 of dermatitis, and 2 of infertility. Three surgeons required surgery for thyroid nodules, cataracts or neoplasm.
Conclusions: IRC is a common practice in spinal surgery. One-piece leaded aprons are the most commonly used method and they are often combined with other elements, but it is not known when aprons must be replaced. One in 3 surgeons suffered from the studied conditions, and there were 3 related surgeries. Lack of adequate protection and control is a reality for specialist surgeons, together with a lack of protocols, making this an unregulated issue.Facultad de Ciencias Médica
modelling and simulation for major incidents
In recent years, there has been a rise in Major Incidents with big impact on the citizens health and the society. Without the possibility of conducting live experiments when it comes to physical and/or toxic trauma, only an accurate in silico reconstruction allows us to identify organizational solutions with the best possible chance of success, in correlation with the limitations on available resources (e.g. medical team, first responders, treatments, transports, and hospitals availability) and with the variability of the characteristic of event (e.g. type of incident, severity of the event and type of lesions). Utilizing modelling and simulation techniques, a simplified mathematical model of physiological evolution for patients involved in physical and toxic trauma incident scenarios has been developed and implemented. The model formalizes the dynamics, operating standards and practices of medical response and the main emergency service in the chain of emergency management during a Major Incident
The Influence of a Continuum Background on Carrier Relaxation in InAs/InGaAs Quantum Dot
We have investigated the ultra-fast carrier dynamics in Molecular Beam Epitaxy (MBE)-grown InAs/InGaAs/GaAs quantum dots (QDs) emitting at 1.3 μm by time resolved photoluminescence (TRPL) upconversion measurements with a time resolution of about 200 fs. Changing the detection energies in the spectral region from the energy of the quantum dots excitonic transition up to the barrier layer absorption edge, we have found that, under high excitation intensity, the intrinsic electronic states are populated mainly by carriers directly captured from the barrier
Il monitoraggio dei movimenti e delle deformazioni con tecniche geomatiche di basso costo
L’osservazione dell’evoluzione di fenomeni di dissesto ha una importanza strategica sul nostro territorio. Un importante precursore di fenomeni franosi è il movimento o la deformazione degli stessi: tali parametri possono essere osservati con tecniche geomatiche. Le misure topografiche o GNSS con ricevitori geodetici (multi-frequenza e multi-costellazione) sono ormai ben consolidate nel trattamento e nella precisione. La realizzazione di sistemi basati su questi sensori non è tuttavia a basso costo, specie se consideriamo tecniche GNSS applicate su molti punti di controllo per una descrizione dettagliata del fenomeno, o installazioni soggette a pericoli oggettivi e dunque da considerarsi praticamente “a perdere”. Ricevitori GNSS singola frequenza sono oggi reperibili a costi minori di cento euro e possono, sotto opportune ipotesi e ingegnerizzazioni, costituire alternative ai ricevitori geodetici. Nell’ambito di un progetto di ricerca finanziato da CSI Piemonte per lo studio di tecnologie di monitoraggio a basso costo, sono stati sviluppati sistemi di acquisizione, trasmissione ed elaborazione dati basati su sensori GNSS singola frequenza di minuscole dimensioni. Il sistema costituisce una sorta di piccola stazione permanente GNSS, integrata con accelerometri per la stima di inclinazione e vibrazioni e con sensori meteorologici. È corredata di micro PC con processore ARM e interfacce di comunicazione wireless a lungo raggio per la trasmissione in tempo reale delle misure. Il sistema risulta caratterizzato da consumi elettrici molto contenuti ed è di rapida installazione in siti anche complessi dal punto di vista dell’accesso, dell’alimentazione e comunicazione. Vengono esposti nella nota i risultati delle prove di accuratezza dei sensori GNSS eseguite in laboratorio, le procedure di calibrazione dei sensori e la loro ingegnerizzazione, oltre ai primi risultati sulle installazioni situate nel nord del Piemonte su alcune zone di dissesto
Significant benefits of AIP testing and clinical screening in familial isolated and young-onset pituitary tumors
Context
Germline mutations in the aryl hydrocarbon receptor-interacting protein (AIP) gene are responsible for a subset of familial isolated pituitary adenoma (FIPA) cases and sporadic pituitary neuroendocrine tumors (PitNETs).
Objective
To compare prospectively diagnosed AIP mutation-positive (AIPmut) PitNET patients with clinically presenting patients and to compare the clinical characteristics of AIPmut and AIPneg PitNET patients.
Design
12-year prospective, observational study.
Participants & Setting
We studied probands and family members of FIPA kindreds and sporadic patients with disease onset ≤18 years or macroadenomas with onset ≤30 years (n = 1477). This was a collaborative study conducted at referral centers for pituitary diseases.
Interventions & Outcome
AIP testing and clinical screening for pituitary disease. Comparison of characteristics of prospectively diagnosed (n = 22) vs clinically presenting AIPmut PitNET patients (n = 145), and AIPmut (n = 167) vs AIPneg PitNET patients (n = 1310).
Results
Prospectively diagnosed AIPmut PitNET patients had smaller lesions with less suprasellar extension or cavernous sinus invasion and required fewer treatments with fewer operations and no radiotherapy compared with clinically presenting cases; there were fewer cases with active disease and hypopituitarism at last follow-up. When comparing AIPmut and AIPneg cases, AIPmut patients were more often males, younger, more often had GH excess, pituitary apoplexy, suprasellar extension, and more patients required multimodal therapy, including radiotherapy. AIPmut patients (n = 136) with GH excess were taller than AIPneg counterparts (n = 650).
Conclusions
Prospectively diagnosed AIPmut patients show better outcomes than clinically presenting cases, demonstrating the benefits of genetic and clinical screening. AIP-related pituitary disease has a wide spectrum ranging from aggressively growing lesions to stable or indolent disease course
- …