1,158 research outputs found

    Measuring diet in primary school children aged 8-11 years: validation of the Child and Diet Evaluation Tool (CADET) with an emphasis on fruit and vegetable intake.

    Get PDF
    Background/Objectives:The Child And Diet Evaluation Tool (CADET) is a 24-h food diary that measures the nutrition intake of children aged 3-7 years, with a focus on fruit and vegetable consumption. Until now CADET has not been used to measure nutrient intake of children aged 8-11 years. To ensure that newly assigned portion sizes for this older age group were valid, participants were asked to complete the CADET diary (the school and home food diary) concurrently with a 1-day weighed record. Subjects/Methods:A total of 67 children with a mean age of 9.3 years (s.d.: ± 1.4, 51% girls) participated in the study. Total fruit and vegetable intake in grams and other nutrients were extracted to compare the mean intakes from the CADET diary and Weighed record using t-tests and Pearson's r correlations. Bland-Altman analysis was also conducted to assess the agreement between the two methods. Results: Correlations comparing the CADET diary to the weighed record were high for fruit, vegetables and combined fruit and vegetables (r=0.7). The results from the Bland-Altman plots revealed a mean difference of 54 g (95% confidence interval: -88, 152) for combined fruit and vegetables intake. CADET is the only tool recommended by the National Obesity Observatory that has been validated in a UK population and provides nutrient level data on children's diets. Conclusions:The results from this study conclude that CADET can provide high-quality nutrient data suitable for evaluating intervention studies now for children aged 3-11 years with a focus on fruit and vegetable intake

    A novel isolator-based system promotes viability of human embryos during laboratory processing

    Get PDF
    In vitro fertilisation (IVF) and related technologies are arguably the most challenging of all cell culture applications. The starting material is a single cell from which one aims to produce an embryo capable of establishing a pregnancy eventually leading to a live birth. Laboratory processing during IVF treatment requires open manipulations of gametes and embryos, which typically involves exposure to ambient conditions. To reduce the risk of cellular stress, we have developed a totally enclosed system of interlinked isolator-based workstations designed to maintain oocytes and embryos in a physiological environment throughout the IVF process. Comparison of clinical and laboratory data before and after the introduction of the new system revealed that significantly more embryos developed to the blastocyst stage in the enclosed isolator-based system compared with conventional open-fronted laminar flow hoods. Moreover, blastocysts produced in the isolator-based system contained significantly more cells and their development was accelerated. Consistent with this, the introduction of the enclosed system was accompanied by a significant increase in the clinical pregnancy rate and in the proportion of embryos implanting following transfer to the uterus. The data indicate that protection from ambient conditions promotes improved development of human embryos. Importantly, we found that it was entirely feasible to conduct all IVF-related procedures in the isolator-based workstations

    Twenty-four hour metabolic rate measurements utilized as a reference to evaluate several prediction equations for calculating energy requirements in healthy infants

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To date, only short-duration metabolic rate measurements of less than four hours have been used to evaluate prediction equations for calculating energy requirements in healthy infants. Therefore, the objective of this analysis was to utilize direct 24-hour metabolic rate measurements from a prior study to evaluate the accuracy of several currently used prediction equations for calculating energy expenditure (EE) in healthy infants.</p> <p>Methods</p> <p>Data from 24-hour EE, resting (RMR) and sleeping (SMR) metabolic rates obtained from 10 healthy infants, served as a reference to evaluate 11 length-weight (LWT) and weight (WT) based prediction equations. Six prediction equations have been previously derived from 50 short-term EE measurements in the Enhanced Metabolic Testing Activity Chamber (EMTAC) for assessing 24-hour EE, (EMTACEE-LWT and EMTACEE-WT), RMR (EMTACRMR-LWT and EMTACRMR-WT) and SMR (EMTACSMR-LWT and EMTACSMR-WT). The last five additional prediction equations for calculating RMR consisted of the World Health Organization (WHO), the Schofield (SCH-LWT and SCH-WT) and the Oxford (OXFORD-LWT and OXFORD-WT). Paired t-tests and the Bland & Altman limit analysis were both applied to evaluate the performance of each equation in comparison to the reference data.</p> <p>Results</p> <p>24-hour EE, RMR and SMR calculated with the EMTACEE-WT, EMTACRMR-WT and both the EMTACSMR-LWT and EMTACSMR-WT prediction equations were similar, p = NS, to that obtained from the reference measurements. However, RMR calculated using the WHO, SCH-LWT, SCH-WT, OXFORD-LWT and OXFORD-WT prediction equations were not comparable to the direct 24-hour metabolic measurements (p < 0.05) obtained in the 10 reference infants. Moreover, the EMTACEE-LWT and EMTACRMR-LWT were also not similar (p < 0.05) to direct 24-hour metabolic measurements.</p> <p>Conclusions</p> <p>Weight based prediction equations, derived from short-duration EE measurements in the EMTAC, were accurate for calculating EE, RMR and SMR in healthy infants.</p

    Simultaneous determination of wave speed and arrival time of reflected waves using the pressure-velocity loop

    Get PDF
    This is the post print version of the article. The official published version can be found at the link below.In a previous paper we demonstrated that the linear portion of the pressure–velocity loop (PU-loop) corresponding to early systole could be used to calculate the local wave speed. In this paper we extend this work to show that determination of the time at which the PU-loop first deviates from linearity provides a convenient way to determine the arrival time of reflected waves (Tr). We also present a new technique using the PU-loop that allows for the determination of wave speed and Tr simultaneously. We measured pressure and flow in elastic tubes of different diameters, where a strong reflection site existed at known distances away form the measurement site. We also measured pressure and flow in the ascending aorta of 11 anaesthetised dogs where a strong reflection site was produced through total arterial occlusion at four different sites. Wave speed was determined from the initial slope of the PU-loop and Tr was determined using a new algorithm that detects the sampling point at which the initial linear part of the PU-loop deviates from linearity. The results of the new technique for detecting Tr were comparable to those determined using the foot-to-foot and wave intensity analysis methods. In elastic tubes Tr detected using the new algorithm was almost identical to that detected using wave intensity analysis and foot-to-foot methods with a maximum difference of 2%. Tr detected using the PU-loop in vivo highly correlated with that detected using wave intensity analysis (r 2 = 0.83, P < 0.001). We conclude that the new technique described in this paper offers a convenient and objective method for detecting Tr, and allows for the dynamic determination of wave speed and Tr, simultaneously

    Measuring the health impact of human rights violations related to Australian asylum policies and practices: A mixed methods study

    Get PDF
    This article has been made available through the Brunel Open Access Publishing Fund - Copyright @ 2009 Johnston et al.BACKGROUND: Human rights violations have adverse consequences for health. However, to date, there remains little empirical evidence documenting this association, beyond the obvious physical and psychological effects of torture. The primary aim of this study was to investigate whether Australian asylum policies and practices, which arguably violate human rights, are associated with adverse health outcomes. METHODS: We designed a mixed methods study to address the study aim. A cross-sectional survey was conducted with 71 Iraqi Temporary Protection Visa (TPV) refugees and 60 Iraqi Permanent Humanitarian Visa (PHV) refugees, residing in Melbourne, Australia. Prior to a recent policy amendment, TPV refugees were only given temporary residency status and had restricted access to a range of government funded benefits and services that permanent refugees are automatically entitled to. The quantitative results were triangulated with semi-structured interviews with TPV refugees and service providers. The main outcome measures were self-reported physical and psychological health. Standardised self-report instruments, validated in an Arabic population, were used to measure health and wellbeing outcomes. RESULTS: Forty-six percent of TPV refugees compared with 25% of PHV refugees reported symptoms consistent with a diagnosis of clinical depression (p = 0.003). After controlling for the effects of age, gender and marital status, TPV status made a statistically significant contribution to psychological distress (B = 0.5, 95% CI 0.3 to 0.71, p </= 0.001) amongst Iraqi refugees. Qualitative data revealed that TPV refugees generally felt socially isolated and lacking in control over their life circumstances, because of their experiences in detention and on a temporary visa. This sense of powerlessness and, for some, an implicit awareness they were being denied basic human rights, culminated in a strong sense of injustice. CONCLUSION: Government asylum policies and practices violating human rights norms are associated with demonstrable psychological health impacts. This link between policy, rights violations and health outcomes offers a framework for addressing the impact of socio-political structures on health.This research was supported by an Australian National and Medical Research Council PhD Scholarship (N. 251782) and a Victorian Health Promotion Foundation research grant (No. 2002-0280)

    Anterior Chamber Measurements by Pentacam and AS-OCT in Eyes With Normal Open Angles

    Get PDF
    PURPOSE: To assess the reproducibility and agreement of anterior chamber measurements between the Pentacam (PTC) and the Anterior segment optical coherence tomography (AOCT) in normal healthy eyes with open angle. METHODS: Prospective cross-sectional comparative case series. A total of 162 eyes of 81 healthy volunteers with normal open angle were included in this study. Anterior chamber angle (ACA) and anterior chamber depth (ACD) were measured with PTC and AOCT. Intra-observer variability and inter-methods agreement of both instruments for ACA and ACD were evaluated. RESULTS: Values of temporal and nasal ACA measured by two instruments were similar, and the results of ACD were also not significantly different between modalities (p > 0.01). ACA and ACD measurements by PTC and AOCT showed good intra-observer and inter-method agreements (all > 0.9). CONCLUSIONS: PTC and AOCT are presumed to be very useful for the anterior chamber angle examination. They may provide good images and quantitative data about the angle structures including ACA and ACDope

    Reasoning deficits among illicit drug users are associated with aspects of cannabis use

    Get PDF
    Background. Deficits in deductive reasoning have been observed among ecstasy/polydrug users. The present study seeks to investigate dose-related effects of specific drugs and whether these vary with the cognitive demands of the task. Methods. One hundred and five participants (mean age 21.33, S.D. 3.14; 77 females, 28 males) attempted to generate solutions for eight one-model syllogisms and one syllogism for which there was no valid conclusion (NVC). All of the one model syllogisms generated at least one valid conclusion and six generated two valid conclusions. In these six cases one of the conclusions was classified as common and the other as non-common. Results. The number of valid common inferences was negatively associated with aspects of short term cannabis use and with measures of IQ. The outcomes observed were more than simple post intoxication effects since cannabis use in the 10 days immediately before testing was unrelated to reasoning performance. Following adjustment for multiple comparisons, the number of non-common valid inferences was not significantly associated with any of the drug use measures. Conclusions. Recent cannabis use appears to impair the processes associated with generating valid common inferences while not affecting the production of non-common inferences. It is possible, therefore, that the two types of inference may recruit different executive resources which may differ in their susceptibility to cannabis-related effects

    Reduced functional measure of cardiovascular reserve predicts admission to critical care unit following kidney transplantation

    Get PDF
    Background: There is currently no effective preoperative assessment for patients undergoing kidney transplantation that is able to identify those at high perioperative risk requiring admission to critical care unit (CCU). We sought to determine if functional measures of cardiovascular reserve, in particular the anaerobic threshold (VO2AT) could identify these patients. Methods: Adult patients were assessed within 4 weeks prior to kidney transplantation in a University hospital with a 37-bed CCU, between April 2010 and June 2012. Cardiopulmonary exercise testing (CPET), echocardiography and arterial applanation tonometry were performed. Results: There were 70 participants (age 41.7614.5 years, 60% male, 91.4% living donor kidney recipients, 23.4% were desensitized). 14 patients (20%) required escalation of care from the ward to CCU following transplantation. Reduced anaerobic threshold (VO2AT) was the most significant predictor, independently (OR = 0.43; 95% CI 0.27–0.68; p,0.001) and in the multivariate logistic regression analysis (adjusted OR = 0.26; 95% CI 0.12–0.59; p = 0.001). The area under the receiveroperating- characteristic curve was 0.93, based on a risk prediction model that incorporated VO2AT, body mass index and desensitization status. Neither echocardiographic nor measures of aortic compliance were significantly associated with CCU admission. Conclusions: To our knowledge, this is the first prospective observational study to demonstrate the usefulness of CPET as a preoperative risk stratification tool for patients undergoing kidney transplantation. The study suggests that VO2AT has the potential to predict perioperative morbidity in kidney transplant recipients

    Test-retest reliability of knee kinesthesia in healthy adults

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Sensory information from mechanoreceptors in the skin, muscles, tendons, and joint structures plays an important role in joint stability. A joint injury can lead to disruption of the sensory system, which can be measured by proprioceptive acuity. When evaluating proprioception, assessment tools need to be reliable. The aim of this study was to assess the test-retest reliability of a device designed to measure knee proprioception.</p> <p>Methods</p> <p>Twenty-four uninjured individuals (14 women and 10 men) were examined with regard to test-retest reliability of knee kinesthesia, measured by the threshold to detection of passive motion (TDPM). Measurements were performed towards extension and flexion from the two starting positions, 20 degrees and 40 degrees knee joint flexion, giving four variables. The mean difference between test and retest together with the 95% confidence interval (test 2 minus test 1), the intraclass correlation coefficient (ICC<sub>2,1</sub>), and Bland and Altman graphs with limits of agreement, were used as statistical methods for assessing test-retest reliability.</p> <p>Results</p> <p>The intraclass correlation coefficients ranged from 0.59 to 0.70 in all variables except one. No difference was found between test and retest in three of the four TDPM variables. TDPM would need to decrease between 10% and 38%, and increase between 17% and 24% in groups of uninjured subjects to be 95% confident of detecting a real change. The limits of agreement were rather wide in all variables. The variables associated with the 20-degree starting position tended to have higher intraclass correlation coefficients and narrower limits of agreement than those associated with 40 degrees.</p> <p>Conclusion</p> <p>Three TDPM variables were considered reliable for observing change in groups of subjects without pathology. However, the limits of agreement revealed that small changes in an individual's performance cannot be detected. The higher intraclass correlation coefficients and the narrower limits of agreement in the variables associated with the starting position of 20 degrees knee joint flexion, indicate that these variables are more reliable than those associated with 40 degrees. We, therefore, recommend that the TDPM be measured with a 20-degree starting position.</p
    corecore