104 research outputs found

    In Vivo Measurement of Hippocampal GABAA/cBZR Density with [18F]-Flumazenil PET for the Study of Disease Progression in an Animal Model of Temporal Lobe Epilepsy

    Get PDF
    PURPOSE: Imbalance of inhibitory GABAergic neurotransmission has been proposed to play a role in the pathogenesis of temporal lobe epilepsy (TLE). This study aimed to investigate whether [(18)F]-flumazenil ([(18)F]-FMZ) PET could be used to non-invasively characterise GABA(A)/central benzodiazepine receptor (GABA(A)/cBZR) density and affinity in vivo in the post-kainic acid status epilepticus (SE) model of TLE. METHODS: Dynamic [(18)F]-FMZ -PET scans using a multi-injection protocol were acquired in four male wistar rats for validation of the partial saturation model (PSM). SE was induced in eight male Wistar rats (10 weeks of age) by i.p. injection of kainic acid (7.5–25 mg/kg), while control rats (n = 7) received saline injections. Five weeks post-SE, an anatomic MRI scan was acquired and the following week an [(18)F]-FMZ PET scan (3.6–4.6 nmol). The PET data was co-registered to the MRI and regions of interest drawn on the MRI for selected structures. A PSM was used to derive receptor density and apparent affinity from the [(18)F]-FMZ PET data. KEY FINDINGS: The PSM was found to adequately model [(18)F]-FMZ binding in vivo. There was a significant decrease in hippocampal receptor density in the SE group (p<0.01), accompanied by an increase in apparent affinity (p<0.05) compared to controls. No change in cortical receptor binding was observed. Hippocampal volume reduction and cell loss was only seen in a subset of animals. Histological assessment of hippocampal cell loss was significantly correlated with hippocampal volume measured by MRI (p<0.05), but did not correlate with [(18)F]-FMZ binding. SIGNIFICANCE: Alterations to hippocampal GABA(A)/cBZR density and affinity in the post-kainic acid SE model of TLE are detectable in vivo with [(18)F]-FMZ PET and a PSM. These changes are independent from hippocampal cell and volume loss. [(18)F]-FMZ PET is useful for investigating the role that changes GABA(A)/cBZR density and binding affinity play in the pathogenesis of TLE

    Beam test results for the FiberGLAST instrument

    Get PDF
    The FiberGLAST scintillating fiber telescope is a large-area instrument concept for NASA\u27s GLAST program. The detector is designed for high-energy gamma-ray astronomy, and uses plastic scintillating fibers to combine a photon pair tracking telescope and a calorimeter into a single instrument. A small prototype detector has been tested with high energy photons at the Thomas Jefferson National Accelerator Facility. We report on the result of this beam test, including scintillating fiber performance, photon track reconstruction, angular resolution, and detector efficiency

    Estimation of GRB detection by FiberGLAST

    Get PDF
    FiberGLAST is one of several instrument concepts being developed for possible inclusion as the primary Gamma-ray Large Area Space Telescope (GLAST) instrument. The predicted FiberGLAST effective area is more than 12,000 cm2 for energies between 30 MeV and 300 GeV, with a field of view that is essentially flat from 0°–80°. The detector will achieve a sensitivity more than 10 times that of EGRET. We present results of simulations that illustrate the sensitivity of FiberGLAST for the detection of gamma-ray bursts

    Development and testing of a fiber/multianode photomultiplier system for use on FiberGLAST

    Get PDF
    A scintillating fiber detector is currently being studied for the NASA Gamma-Ray Large Area Space Telescope (GLAST) mission. This detector utilizes modules composed of a thin converter sheet followed by an x, y plane of scintillating fibers to examine the shower of particles created by high energy gamma-rays interacting in the converter material. The detector is composed of a tracker with 90 such modular planes and a calorimeter with 36 planes. The two major component of this detector are the scintillating fibers and their associated photodetectors. Here we present current status of development and test result of both of these. The Hamamatsu R5900-00-M64 multianode photomultiplier tube (MAPMT) is the baseline readout device. A characterization of this device has been performed including noise, cross- talk, gain variation, vibration, and thermal/vacuum test. A prototype fiber/MAPMT system has been tested at the Center for Advanced Microstructures and Devices at Louisiana State University with a photon beam and preliminary results are presented

    Test-Retest Variability and Discriminatory Power of Measurements From Microperimetry and Dark Adaptation Assessment in People With Intermediate Age-Related Macular Degeneration – A MACUSTAR Study Report

    Get PDF
    Purpose: The purpose of this study was to assess test-retest variability and discriminatory power of measures from macular integrity assessment (S-MAIA) and AdaptDx. // Methods: This is a cross-sectional study of 167 people with intermediate age-related macular degeneration (iAMD), no AMD (controls; n = 54), early AMD (n = 28), and late AMD (n = 41), recruited across 18 European ophthalmology centers. Repeat measures of mesopic and scotopic S-MAIA average (mean) threshold (MMAT decibels [dB] and SMAT [dB]) and rod intercept time (RIT [mins]) at 2 visits 14 (±7) days apart were recorded. Repeat measures were assessed by Bland-Altman analysis, intra-class correlation coefficients (ICCs) and variability ratios. Secondary analysis assessed the area under the receiver operating characteristic curves (AUC) to determine the ability to distinguish people as having no AMD, early AMD, or iAMD. // Results: Data were available for 128, 131, and 103 iAMD participants for the mesopic and scotopic S-MAIA and AdaptDx, respectively. MMAT and SMAT demonstrate similar test-retest variability in iAMD (95% confidence interval [CI] ICC of 0.79–0.89 and 0.78–0.89, respectively). ICCs were worse in RIT (95% CI ICC = 0.55–0.77). All tests had equivalent AUCs (approximately 70%) distinguishing between subjects with iAMD and controls, whereas early AMD was indistinguishable from iAMD on all measures (AUC = <55%). A learning effect was not seen in these assessments under the operating procedures used. // Conclusions: MMAT, SMAT, and RIT have adequate test-retest variability and are all moderately good at separating people with iAMD from controls. // Translational Relevance: Expected levels of test-retest variability and discriminatory power of the AdaptDx and MAIA devices in a clinical study setting must be considered when designing future trials for people with AMD

    GABAA-Mediated Inhibition Modulates Stimulus-Specific Adaptation in the Inferior Colliculus

    Get PDF
    The ability to detect novel sounds in a complex acoustic context is crucial for survival. Neurons from midbrain through cortical levels adapt to repetitive stimuli, while maintaining responsiveness to rare stimuli, a phenomenon called stimulus-specific adaptation (SSA). The site of origin and mechanism of SSA are currently unknown. We used microiontophoretic application of gabazine to examine the role of GABAA-mediated inhibition in SSA in the inferior colliculus, the midbrain center for auditory processing. We found that gabazine slowed down the process of adaptation to high probability stimuli but did not abolish it, with response magnitude and latency still depending on the probability of the stimulus. Blocking GABAA receptors increased the firing rate to high and low probability stimuli, but did not completely equalize the responses. Together, these findings suggest that GABAA-mediated inhibition acts as a gain control mechanism that enhances SSA by modifying the responsiveness of the neuron

    New developments in the InterPro database

    Get PDF
    InterPro is an integrated resource for protein families, domains and functional sites, which integrates the following protein signature databases: PROSITE, PRINTS, ProDom, Pfam, SMART, TIGRFAMs, PIRSF, SUPERFAMILY, Gene3D and PANTHER. The latter two new member databases have been integrated since the last publication in this journal. There have been several new developments in InterPro, including an additional reading field, new database links, extensions to the web interface and additional match XML files. InterPro has always provided matches to UniProtKB proteins on the website and in the match XML file on the FTP site. Additional matches to proteins in UniParc (UniProt archive) are now available for download in the new match XML files only. The latest InterPro release (13.0) contains more than 13 000 entries, covering over 78% of all proteins in UniProtKB. The database is available for text- and sequence-based searches via a webserver (), and for download by anonymous FTP (). The InterProScan search tool is now also available via a web service at

    A Cross-Sectional Study of Barriers to Personal Health Record Use among Patients Attending a Safety-Net Clinic

    Get PDF
    BACKGROUND: Personal health records (PHR) may improve patients' health by providing access to and context for health information. Among patients receiving care at a safety-net HIV/AIDS clinic, we examined the hypothesis that a mental health (MH) or substance use (SU) condition represents a barrier to engagement with web-based health information, as measured by consent to participate in a trial that provided access to personal (PHR) or general (non-PHR) health information portals and by completion of baseline study surveys posted there. METHODS: Participants were individually trained to access and navigate individualized online accounts and to complete study surveys. In response to need, during accrual months 4 to 12 we enhanced participant training to encourage survey completion with the help of staff. Using logistic regression models, we estimated odds ratios for study participation and for survey completion by combined MH/SU status, adjusted for levels of computer competency, on-study training, and demographics. RESULTS: Among 2,871 clinic patients, 70% had MH/SU conditions, with depression (38%) and methamphetamine use (17%) most commonly documented. Middle-aged patients and those with a MH/SU condition were over-represented among study participants (N = 338). Survey completion was statistically independent of MH/SU status (OR, 1.85 [95% CI, 0.93-3.66]) but tended to be higher among those with MH/SU conditions. Completion rates were low among beginner computer users, regardless of training level (<50%), but adequate among advanced users (>70%). CONCLUSIONS: Among patients attending a safety-net clinic, MH/SU conditions were not barriers to engagement with web-based health information. Instead, level of computer competency was useful for identifying individuals requiring substantial computer training in order to fully participate in the study. Intensive on-study training was insufficient to enable beginner computer users to complete study surveys
    • …
    corecore