78 research outputs found

    Stereocontrolled Total Synthesis of 1a,25-Dihydroxyergocalciferol

    Get PDF
    A stereocontrolled total synthesis of the vitamin D2metabolite 1a,25-dihydroxyergocalciferol (1), which involves a coupling of the previously described A ring synthon 2 with the appropriately functionalized C-D moiety 3, is described. In the key step, stereochemical control is achieved by taking advantage of the thermal reversibility of a [3+ 2]-cyc1oaddition of methyl 0,~-dimethylacrylate and the C-D C-23 nitrone 4 to effect conversion to the C-24S isoxazolidinecarboxylic acid methyl ester Sa, which is readily transformed by reduction followed by elimination of the nitrone function into the necessary C-D precursor

    Evading the CKM Hierarchy: Intrinsic Charm in B Decays

    Full text link
    We show that the presence of intrinsic charm in the hadrons' light-cone wave functions, even at a few percent level, provides new, competitive decay mechanisms for B decays which are nominally CKM-suppressed. For example, the weak decays of the B-meson to two-body exclusive states consisting of strange plus light hadrons, such as B\to\pi K, are expected to be dominated by penguin contributions since the tree-level b\to s u\bar u decay is CKM suppressed. However, higher Fock states in the B wave function containing charm quark pairs can mediate the decay via a CKM-favored b\to s c\bar c tree-level transition. Such intrinsic charm contributions can be phenomenologically significant. Since they mimic the amplitude structure of ``charming'' penguin contributions, charming penguins need not be penguins at all.Comment: 28 pages, 6 figures, published version. References added, minor change

    Heavy quarkonium: progress, puzzles, and opportunities

    Get PDF
    A golden age for heavy quarkonium physics dawned a decade ago, initiated by the confluence of exciting advances in quantum chromodynamics (QCD) and an explosion of related experimental activity. The early years of this period were chronicled in the Quarkonium Working Group (QWG) CERN Yellow Report (YR) in 2004, which presented a comprehensive review of the status of the field at that time and provided specific recommendations for further progress. However, the broad spectrum of subsequent breakthroughs, surprises, and continuing puzzles could only be partially anticipated. Since the release of the YR, the BESII program concluded only to give birth to BESIII; the BB-factories and CLEO-c flourished; quarkonium production and polarization measurements at HERA and the Tevatron matured; and heavy-ion collisions at RHIC have opened a window on the deconfinement regime. All these experiments leave legacies of quality, precision, and unsolved mysteries for quarkonium physics, and therefore beg for continuing investigations. The plethora of newly-found quarkonium-like states unleashed a flood of theoretical investigations into new forms of matter such as quark-gluon hybrids, mesonic molecules, and tetraquarks. Measurements of the spectroscopy, decays, production, and in-medium behavior of c\bar{c}, b\bar{b}, and b\bar{c} bound states have been shown to validate some theoretical approaches to QCD and highlight lack of quantitative success for others. The intriguing details of quarkonium suppression in heavy-ion collisions that have emerged from RHIC have elevated the importance of separating hot- and cold-nuclear-matter effects in quark-gluon plasma studies. This review systematically addresses all these matters and concludes by prioritizing directions for ongoing and future efforts.Comment: 182 pages, 112 figures. Editors: N. Brambilla, S. Eidelman, B. K. Heltsley, R. Vogt. Section Coordinators: G. T. Bodwin, E. Eichten, A. D. Frawley, A. B. Meyer, R. E. Mitchell, V. Papadimitriou, P. Petreczky, A. A. Petrov, P. Robbe, A. Vair

    Upper limits on the strength of periodic gravitational waves from PSR J1939+2134

    Get PDF
    The first science run of the LIGO and GEO gravitational wave detectors presented the opportunity to test methods of searching for gravitational waves from known pulsars. Here we present new direct upper limits on the strength of waves from the pulsar PSR J1939+2134 using two independent analysis methods, one in the frequency domain using frequentist statistics and one in the time domain using Bayesian inference. Both methods show that the strain amplitude at Earth from this pulsar is less than a few times 10−2210^{-22}.Comment: 7 pages, 1 figure, to appear in the Proceedings of the 5th Edoardo Amaldi Conference on Gravitational Waves, Tirrenia, Pisa, Italy, 6-11 July 200

    Improving the sensitivity to gravitational-wave sources by modifying the input-output optics of advanced interferometers

    Get PDF
    We study frequency dependent (FD) input-output schemes for signal-recycling interferometers, the baseline design of Advanced LIGO and the current configuration of GEO 600. Complementary to a recent proposal by Harms et al. to use FD input squeezing and ordinary homodyne detection, we explore a scheme which uses ordinary squeezed vacuum, but FD readout. Both schemes, which are sub-optimal among all possible input-output schemes, provide a global noise suppression by the power squeeze factor, while being realizable by using detuned Fabry-Perot cavities as input/output filters. At high frequencies, the two schemes are shown to be equivalent, while at low frequencies our scheme gives better performance than that of Harms et al., and is nearly fully optimal. We then study the sensitivity improvement achievable by these schemes in Advanced LIGO era (with 30-m filter cavities and current estimates of filter-mirror losses and thermal noise), for neutron star binary inspirals, and for narrowband GW sources such as low-mass X-ray binaries and known radio pulsars. Optical losses are shown to be a major obstacle for the actual implementation of these techniques in Advanced LIGO. On time scales of third-generation interferometers, like EURO/LIGO-III (~2012), with kilometer-scale filter cavities, a signal-recycling interferometer with the FD readout scheme explored in this paper can have performances comparable to existing proposals. [abridged]Comment: Figs. 9 and 12 corrected; Appendix added for narrowband data analysi

    Quantum state preparation and macroscopic entanglement in gravitational-wave detectors

    Full text link
    Long-baseline laser-interferometer gravitational-wave detectors are operating at a factor of 10 (in amplitude) above the standard quantum limit (SQL) within a broad frequency band. Such a low classical noise budget has already allowed the creation of a controlled 2.7 kg macroscopic oscillator with an effective eigenfrequency of 150 Hz and an occupation number of 200. This result, along with the prospect for further improvements, heralds the new possibility of experimentally probing macroscopic quantum mechanics (MQM) - quantum mechanical behavior of objects in the realm of everyday experience - using gravitational-wave detectors. In this paper, we provide the mathematical foundation for the first step of a MQM experiment: the preparation of a macroscopic test mass into a nearly minimum-Heisenberg-limited Gaussian quantum state, which is possible if the interferometer's classical noise beats the SQL in a broad frequency band. Our formalism, based on Wiener filtering, allows a straightforward conversion from the classical noise budget of a laser interferometer, in terms of noise spectra, into the strategy for quantum state preparation, and the quality of the prepared state. Using this formalism, we consider how Gaussian entanglement can be built among two macroscopic test masses, and the performance of the planned Advanced LIGO interferometers in quantum-state preparation

    The HEV Ventilator

    Full text link
    HEV is a low-cost, versatile, high-quality ventilator, which has been designed in response to the COVID-19 pandemic. The ventilator is intended to be used both in and out of hospital intensive care units, and for both invasive and non-invasive ventilation. The hardware can be complemented with an external turbine for use in regions where compressed air supplies are not reliably available. The standard modes provided include PC-A/C(Pressure Assist Control),PC-A/C-PRVC(Pressure Regulated Volume Control), PC-PSV (Pressure Support Ventilation) and CPAP (Continuous Positive airway pressure). HEV is designed to support remote training and post market surveillance via a web interface and data logging to complement the standard touch screen operation, making it suitable for a wide range of geographical deployment. The HEV design places emphasis on the quality of the pressure curves and the reactivity of the trigger, delivering a global performance which will be applicable to ventilator needs beyond theCOVID-19 pandemic. This article describes the conceptual design and presents the prototype units together with their performance evaluation.Comment: 34 pages, 18 figures, Extended version of the article submitted to PNA

    Non-invasive cardiac imaging techniques and vascular tools for the assessment of cardiovascular disease in type 2 diabetes mellitus

    Get PDF
    Cardiovascular disease is the major cause of mortality in type 2 diabetes mellitus. The criteria for the selection of those asymptomatic patients with type 2 diabetes who should undergo cardiac screening and the therapeutic consequences of screening remain controversial. Non-invasive techniques as markers of atherosclerosis and myocardial ischaemia may aid risk stratification and the implementation of tailored therapy for the patient with type 2 diabetes. In the present article we review the literature on the implementation of non-invasive vascular tools and cardiac imaging techniques in this patient group. The value of these techniques as endpoints in clinical trials and as risk estimators in asymptomatic diabetic patients is discussed. Carotid intima–media thickness, arterial stiffness and flow-mediated dilation are abnormal long before the onset of type 2 diabetes. These vascular tools are therefore most likely to be useful for the identification of ‘at risk’ patients during the early stages of atherosclerotic disease. The additional value of these tools in risk stratification and tailored therapy in type 2 diabetes remains to be proven. Cardiac imaging techniques are more justified in individuals with a strong clinical suspicion of advanced coronary heart disease (CHD). Asymptomatic myocardial ischaemia can be detected by stress echocardiography and myocardial perfusion imaging. The more recently developed non-invasive multi-slice computed tomography angiography is recommended for exclusion of CHD, and can therefore be used to screen asymptomatic patients with type 2 diabetes, but has the associated disadvantages of high radiation exposure and costs. Therefore, we propose an algorithm for the screening of asymptomatic diabetic patients, the first step of which consists of coronary artery calcium score assessment and exercise ECG
    • 

    corecore