1,623 research outputs found
Real World Interpretations of Quantum Theory
I propose a new class of interpretations, {\it real world interpretations},
of the quantum theory of closed systems. These interpretations postulate a
preferred factorization of Hilbert space and preferred projective measurements
on one factor. They give a mathematical characterisation of the different
possible worlds arising in an evolving closed quantum system, in which each
possible world corresponds to a (generally mixed) evolving quantum state. In a
realistic model, the states corresponding to different worlds should be
expected to tend towards orthogonality as different possible quasiclassical
structures emerge or as measurement-like interactions produce different
classical outcomes. However, as the worlds have a precise mathematical
definition, real world interpretations need no definition of quasiclassicality,
measurement, or other concepts whose imprecision is problematic in other
interpretational approaches. It is natural to postulate that precisely one
world is chosen randomly, using the natural probability distribution, as the
world realised in Nature, and that this world's mathematical characterisation
is a complete description of reality.Comment: Minor revisions. To appear in Foundations of Physic
The excited hadron spectrum in lattice QCD using a new method of estimating quark propagation
Progress in determining the spectrum of excited baryons and mesons in lattice
QCD is described. Large sets of carefully-designed hadron operators have been
studied and their effectiveness in facilitating the extraction of excited-state
energies is demonstrated. A new method of stochastically estimating the
low-lying effects of quark propagation is proposed which will allow reliable
determinations of temporal correlations of single-hadron and multi-hadron
operators.Comment: 5 pages, 4 figures, talk given at Hadron 2009, Tallahassee, Florida,
December 1, 200
Solving the measurement problem: de Broglie-Bohm loses out to Everett
The quantum theory of de Broglie and Bohm solves the measurement problem, but
the hypothetical corpuscles play no role in the argument. The solution finds a
more natural home in the Everett interpretation.Comment: 20 pages; submitted to special issue of Foundations of Physics, in
honour of James T. Cushin
Decoherence, the measurement problem, and interpretations of quantum mechanics
Environment-induced decoherence and superselection have been a subject of
intensive research over the past two decades, yet their implications for the
foundational problems of quantum mechanics, most notably the quantum
measurement problem, have remained a matter of great controversy. This paper is
intended to clarify key features of the decoherence program, including its more
recent results, and to investigate their application and consequences in the
context of the main interpretive approaches of quantum mechanics.Comment: 41 pages. Final published versio
Quantifying forest reference conditions for ecological restoration: The Woolsey Plots
Sixty-six of the approximately 140 original historical plots (or 47percent) have been relocated on eight National Forests thus far. Of these 66 relocated plots 0 (0/13) are spruce-fir, 13 (13/29) are mixed conifer, and the remainder 53 (53/98) are dominated by ponderosa pine (at least historically pine dominated). This study focused on the ponderosa pine-dominated plots, of which we have relocated over 54 percent. NOTE: This total does NOT include those historical plots located on the Long Valley Experimental Forest near Clints Well, AZ
Limit Cycles in Four Dimensions
We present an example of a limit cycle, i.e., a recurrent flow-line of the
beta-function vector field, in a unitary four-dimensional gauge theory. We thus
prove that beta functions of four-dimensional gauge theories do not produce
gradient flows. The limit cycle is established in perturbation theory with a
three-loop calculation which we describe in detail.Comment: 12 pages, 1 figure. Significant revision of the interpretation of our
result. Improved description of three-loop calculatio
The near-infrared size-luminosity relations for Herbig Ae/Be disks
We report the results of a sensitive K-band survey of Herbig Ae/Be disk sizes
using the 85-m baseline Keck Interferometer. Targets were chosen to span the
maximum range of stellar properties to probe the disk size dependence on
luminosity and effective temperature. For most targets, the measured
near-infrared sizes (ranging from 0.2 to 4 AU) support a simple disk model
possessing a central optically-thin (dust-free) cavity, ringed by hot dust
emitting at the expected sublimation temperatures (T_sub~1000-1500K).
Furthermore, we find a tight correlation of disk size with source luminosity R
propto L^(1/2) for Ae and late Be systems (valid over more than 2 decades in
luminosity), confirming earlier suggestions based on lower-quality data.
Interestingly, the inferred dust-free inner cavities of the highest luminosity
sources (Herbig B0-B3 stars) are under-sized compared to predictions of the
optically-thin cavity model, likely due to optically-thick gas within the inner
AU.Comment: Accepted by Astrophysical Journal; 24 pages, 4 figures, 4 table
A Cryogenic Silicon Interferometer for Gravitational-wave Detection
The detection of gravitational waves from compact binary mergers by LIGO has opened the era of gravitational wave astronomy, revealing a previously hidden side of the cosmos. To maximize the reach of the existing LIGO observatory facilities, we have designed a new instrument that will have 5 times the range of Advanced LIGO, or greater than 100 times the event rate. Observations with this new instrument will make possible dramatic steps toward understanding the physics of the nearby universe, as well as observing the universe out to cosmological distances by the detection of binary black hole coalescences. This article presents the instrument design and a quantitative analysis of the anticipated noise floor
Malaria rapid diagnostic kits: quality of packaging, design and labelling of boxes and components and readability and accuracy of information inserts
<p>Abstract</p> <p>Background</p> <p>The present study assessed malaria RDT kits for adequate and correct packaging, design and labelling of boxes and components. Information inserts were studied for readability and accuracy of information.</p> <p>Methods</p> <p>Criteria for packaging, design, labelling and information were compiled from Directive 98/79 of the European Community (EC), relevant World Health Organization (WHO) documents and studies on end-users' performance of RDTs. Typography and readability level (Flesch-Kincaid grade level) were assessed.</p> <p>Results</p> <p>Forty-two RDT kits from 22 manufacturers were assessed, 35 of which had evidence of good manufacturing practice according to available information (<it>i.e</it>. CE-label affixed or inclusion in the WHO list of ISO13485:2003 certified manufacturers). Shortcomings in devices were (i) insufficient place for writing sample identification (n = 40) and (ii) ambiguous labelling of the reading window (n = 6). Buffer vial labels were lacking essential information (n = 24) or were of poor quality (n = 16). Information inserts had elevated readability levels (median Flesch Kincaid grade 8.9, range 7.1 - 12.9) and user-unfriendly typography (median font size 8, range 5 - 10). Inadequacies included (i) no referral to biosafety (n = 18), (ii) critical differences between depicted and real devices (n = 8), (iii) figures with unrealistic colours (n = 4), (iv) incomplete information about RDT line interpretations (n = 31) and no data on test characteristics (n = 8). Other problems included (i) kit names that referred to <it>Plasmodium vivax </it>although targeting a pan-species <it>Plasmodium </it>antigen (n = 4), (ii) not stating the identity of the pan-species antigen (n = 2) and (iii) slight but numerous differences in names displayed on boxes, device packages and information inserts. Three CE labelled RDT kits produced outside the EC had no authorized representative affixed and the shape and relative dimensions of the CE symbol affixed did not comply with the Directive 98/79/EC. Overall, RDTs with evidence of GMP scored better compared to those without but inadequacies were observed in both groups.</p> <p>Conclusion</p> <p>Overall, malaria RDTs showed shortcomings in quality of construction, design and labelling of boxes, device packages, devices and buffers. Information inserts were difficult to read and lacked relevant information.</p
Exploring Variation and Predictors of Residential Fine Particulate Matter Infiltration
Although individuals spend the majority of their time indoors, most epidemiological studies estimate personal air pollution exposures based on outdoor levels. This almost certainly results in exposure misclassification as pollutant infiltration varies between homes. However, it is often not possible to collect detailed measures of infiltration for individual homes in large-scale epidemiological studies and thus there is currently a need to develop models that can be used to predict these values. To address this need, we examined infiltration of fine particulate matter (PM2.5) and identified determinants of infiltration for 46 residential homes in Toronto, Canada. Infiltration was estimated using the indoor/outdoor sulphur ratio and information on hypothesized predictors of infiltration were collected using questionnaires and publicly available databases. Multiple linear regression was used to develop the models. Mean infiltration was 0.52 ± 0.21 with no significant difference across heating and non-heating seasons. Predictors of infiltration were air exchange, presence of central air conditioning, and forced air heating. These variables accounted for 38% of the variability in infiltration. Without air exchange, the model accounted for 26% of the variability. Effective modelling of infiltration in individual homes remains difficult, although key variables such as use of central air conditioning show potential as an easily attainable indicator of infiltration
- âŠ