22 research outputs found

    X-Ray Repair Cross-Complementing Group 1 (XRCC1) Genetic Polymorphisms and Risk of Childhood Acute Lymphoblastic Leukemia: A Meta-Analysis

    Get PDF
    Background: Recently, there have been a number of studies on the association between XRCC1 polymorphisms and childhood acute lymphoblastic leukemia (ALL) risk. However, the results of previous reports are inconsistent. Thus, we performed a meta-analysis to clarify the effects of XRCC1 variants on childhood ALL risk. Methods: A meta-analysis was performed to examine the association between XRCC1 polymorphisms (Arg399Gln, Arg194Trp, and Arg280His) and childhood ALL risk. We critically reviewed 7 studies with a total of 880 cases and 1311 controls for Arg399Gln polymorphism, 3 studies with a total of 345 cases and 554 controls for Arg280His polymorphism, and 6 studies with a total of 783 cases and 1180 controls for Arg194Trp polymorphism, respectively. Odds ratio (OR) and its 95% confidence interval (CI) were used. Results: Significant association between XRCC1 Arg399Gln polymorphism and childhood ALL risk was observed in total population analyses (OR additive model = 1.501, 95 % CI 1.112–2.026, P OR = 0.008; OR dominant model = 1.316, 95 % CI = 1.104–1.569, POR = 0.002) and Asian subgroup analyses (ORadditive model = 2.338, 95%CI = 1.254–4.359, POR = 0.008; ORdominant model = 2.108, 95%CI = 1.498–2.967, POR = 0.000). No association was detected in Caucasians, Metizo and mixed populations. Ethnicity was considered as a significant source of heterogeneity in the meta-regression model. For the other two XRCC1 polymorphisms, no association with childhood ALL risk was found

    IUD expulsion solved with implant technology

    No full text
    In an attempt to minimize the problem of IUD explusion, implantation technology has been developed and rested. The trials have extended from 1985 until the present time for interval as well as for immediate postabortal and post-placental insertion and fixation of the CuFix IUD (GyneFix (TM)). The present article reports on an ongoing study with GyneFix (TM) interval insertion, with an improved inserter, in 820 women, observed up to 3 years, of whom 213 (25.9%) are nulligravid/nulliparous. The cumulative expulsion rate is 0.6 per 100 women-years at 3 years and is not significantly higher in the nulligravid/nulliparous group. The cumulative pregnancy rate is 0.6 and the cumulative removal rate for medical reasons 3.2 at 3 years. The total experience in this multicenter study covers approximately 14,000 woman-months. It is concluded that the design characteristics of the GyneFix (TM) (fixed, frameless, and flexible) explain the low expulsion, high efficacy and high acceptability rates. The implantation technology is very effective and the improved inserter allows easy insertion and optimal anchoring
    corecore